Simultaneous Detection of Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes at a Very Low Level Using Simultaneous Enrichment Broth and Multichannel SPR Biosensor. Issue 10 (23rd August 2017)
- Record Type:
- Journal Article
- Title:
- Simultaneous Detection of Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes at a Very Low Level Using Simultaneous Enrichment Broth and Multichannel SPR Biosensor. Issue 10 (23rd August 2017)
- Main Title:
- Simultaneous Detection of Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes at a Very Low Level Using Simultaneous Enrichment Broth and Multichannel SPR Biosensor
- Authors:
- Zhang, Xiaoguang
Tsuji, Sachiko
Kitaoka, Hayato
Kobayashi, Hiroshi
Tamai, Mitsuru
Honjoh, Ken‐ichi
Miyamoto, Takahisa - Abstract:
- Abstract : Abstract: Detection of foodborne pathogens at very low levels is still a challenge. A custom‐built multichannel surface plasmon resonance (SPR) biosensor and simultaneous enrichment broth (SEB) were used to develop a simultaneous detection method for 3 important foodborne pathogens, Escherichia coli O157:H7 (O157:H7), Salmonella enteritidis, and Listeria monocytogenes, at a very low level. These 3 foodborne pathogens at a very low level (14, 6, and 28 CFU/25 g (mL) for O157:H7, S. enteritidis, and L. monocytogenes, respectively) were inoculated in SEB and incubated at 37 ˚C for 24 h. Sample prepared from the simultaneous enrichment culture was analyzed using the multichannel SPR biosensor and sensor chip immobilized with polyclonal antibodies specific to each of the target pathogens. O157:H7, S. enteritidis, and L. monocytogenes in chicken were detected simultaneously at an inoculum dose of 14, 6, and 28 CFU/25 g, respectively. Our method using a custom‐built multichannel SPR biosensor and enrichment in SEB is expected as a rapid and simultaneous detection method for low levels of O157:H7, S. enteritidis, and L. monocytogenes in food. Practical Application: Our method is expected as a rapid and simultaneous detection method for pathogens at very low levels. It has great potential for safety control of food and microbiological detection applications.
- Is Part Of:
- Journal of food science. Volume 82:Issue 10(2017)
- Journal:
- Journal of food science
- Issue:
- Volume 82:Issue 10(2017)
- Issue Display:
- Volume 82, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 82
- Issue:
- 10
- Issue Sort Value:
- 2017-0082-0010-0000
- Page Start:
- 2357
- Page End:
- 2363
- Publication Date:
- 2017-08-23
- Subjects:
- antibody -- biosensor -- detection -- foodborne pathogens -- surface plasmon resonance
Food -- Periodicals
Food -- Research -- Periodicals
Food -- Periodicals
Research -- Periodicals
Levensmiddelen
Voeding
664 - Journal URLs:
- http://www.confex2.com/ift/JFSonline8lD4ycqbCLoA/index.html ↗
http://www.ift.org/cms/ ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1750-3841 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwellpublishing.com/journal.asp?ref=0022-1147&site=1 ↗ - DOI:
- 10.1111/1750-3841.13843 ↗
- Languages:
- English
- ISSNs:
- 0022-1147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4984.560000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4799.xml