Detection of pathogenic bacteria in large volume food samples using an enzyme-linked immunoelectrochemical biosensor. (January 2021)
- Record Type:
- Journal Article
- Title:
- Detection of pathogenic bacteria in large volume food samples using an enzyme-linked immunoelectrochemical biosensor. (January 2021)
- Main Title:
- Detection of pathogenic bacteria in large volume food samples using an enzyme-linked immunoelectrochemical biosensor
- Authors:
- Capobianco, Joseph A.
Armstrong, Cheryl M.
Lee, Joe
Gehring, Andrew G. - Abstract:
- Abstract: Increased speed and sensitivity of testing are always desired for the detection of pathogens in foods. Presented a test sample with low microbial analyte concentration, it is an advantage to analyze as much volume as possible of the sample to attain the best limit of detection (LOD). Therefore, a rapid screening method using a novel flow-through immunoelectrochemical biosensor was developed for the detection of pathogenic bacteria ( E. coli O157:H7 and Salmonella ) in food (ground beef). As the working electrode employed was comprised of a porous, antibody-coated graphite felt electrode that served as both a biorecognition-element coated solid support for capture of targeted pathogens as well as a signal transducer, high volumes of aqueous sample could be rapidly exposed to the solid support via gravity flow. Flow rates as high as 16.7 mL/min and 12.3 mL/min could be achieved for bacterial samples in buffer and 1:4 ground meat (beef) homogenate, respectively, with no significant effect on LOD. Fastest flow rates for beef homogenate, without clogging of the porous electrode as well as reduction in apparent electrochemical interference, was realized with a tandem combination of sample pretreatment strategies that included filtration with glass wool and graphite felt as well as continuous flow centrifugation. The LOD for 10, 000 E. coli O157 cells in 5, 60, and 1000 mL of buffer was 2000, 170, and 10 cells/mL, respectively in a total assay time of 3 h whereas the LODAbstract: Increased speed and sensitivity of testing are always desired for the detection of pathogens in foods. Presented a test sample with low microbial analyte concentration, it is an advantage to analyze as much volume as possible of the sample to attain the best limit of detection (LOD). Therefore, a rapid screening method using a novel flow-through immunoelectrochemical biosensor was developed for the detection of pathogenic bacteria ( E. coli O157:H7 and Salmonella ) in food (ground beef). As the working electrode employed was comprised of a porous, antibody-coated graphite felt electrode that served as both a biorecognition-element coated solid support for capture of targeted pathogens as well as a signal transducer, high volumes of aqueous sample could be rapidly exposed to the solid support via gravity flow. Flow rates as high as 16.7 mL/min and 12.3 mL/min could be achieved for bacterial samples in buffer and 1:4 ground meat (beef) homogenate, respectively, with no significant effect on LOD. Fastest flow rates for beef homogenate, without clogging of the porous electrode as well as reduction in apparent electrochemical interference, was realized with a tandem combination of sample pretreatment strategies that included filtration with glass wool and graphite felt as well as continuous flow centrifugation. The LOD for 10, 000 E. coli O157 cells in 5, 60, and 1000 mL of buffer was 2000, 170, and 10 cells/mL, respectively in a total assay time of 3 h whereas the LOD for E. coli O157 was 400 cells/mL in 1:4 beef homogenate. Highlights: Rapid, field portable biosensor for detecting microbial pathogen in foods. Flow-through system enables screening of large sample volumes without subsampling. The working electrode serves as selective capture surface and as signal transducer. … (more)
- Is Part Of:
- Food control. Volume 119(2021)
- Journal:
- Food control
- Issue:
- Volume 119(2021)
- Issue Display:
- Volume 119, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 119
- Issue:
- 2021
- Issue Sort Value:
- 2021-0119-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01
- Subjects:
- Biosensor -- E. coli O157 -- Electrochemical sensor -- Graphite felt -- Immunoelectrochemistry -- Foodborne pathogens
Food -- Quality -- Periodicals
Food -- Analysis -- Periodicals
Food handling -- Periodicals
Food industry and trade -- Quality control -- Periodicals
Aliments -- Industrie et commerce -- Qualité -- Contrôle -- Périodiques
Aliments -- Qualité -- Périodiques
Aliments -- Analyse -- Périodiques
Hygiène alimentaire -- Périodiques
Food -- Analysis
Food handling
Food -- Quality
Periodicals
Electronic journals
664.07 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09567135 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.foodcont.2020.107456 ↗
- Languages:
- English
- ISSNs:
- 0956-7135
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3977.291500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23753.xml