HS-GC-IMS and chemometric data treatment for food authenticity assessment: Olive oil mapping and classification through two different devices as an example. (April 2019)
- Record Type:
- Journal Article
- Title:
- HS-GC-IMS and chemometric data treatment for food authenticity assessment: Olive oil mapping and classification through two different devices as an example. (April 2019)
- Main Title:
- HS-GC-IMS and chemometric data treatment for food authenticity assessment: Olive oil mapping and classification through two different devices as an example
- Authors:
- Contreras, María del Mar
Arroyo-Manzanares, Natalia
Arce, Cristina
Arce, Lourdes - Abstract:
- Abstract: There is a lack of official analytical methods to classify olive oil samples according to its organoleptic quality. For that, headspace-gas chromatography-ion mobility spectrometry (HS-GC-IMS) was applied and two devices with different technical configurations were compared; a commercial isothermal HS-GC-IMS with a 5 cm drift tube and a new HS-GC-IMS prototype, which works at ramped temperature and presents a 10 cm drift tube. Both devices were compared in terms of resolution, precision and classification rates (CRs) using a 30 m non-polar capillary column. Our results suggested that the resolution in the chromatographic separation was improved using the device in which a ramped temperature can be performed in a shorter analysis time and the resolution in the ion mobility separation was also better. The repeatability values (RSD) for the standards quality control were lower than 10% in both cases. Moreover, as revealed in the olive oil 2D-maps, a higher number of markers were detected by the isothermal HS-GC-IMS (91) than that for the ramped temperature device (76), probably explained by the different sensitivity of both devices. These markers were used to build chemometric models based on orthogonal partial least squares-discriminant analysis. The olive oil samples in the validation set could be classified into extra virgin, virgin and lampante, defective and non-defective, as well as edible and non-edible with CRs ranging from 83 to 100%. In order to improve theAbstract: There is a lack of official analytical methods to classify olive oil samples according to its organoleptic quality. For that, headspace-gas chromatography-ion mobility spectrometry (HS-GC-IMS) was applied and two devices with different technical configurations were compared; a commercial isothermal HS-GC-IMS with a 5 cm drift tube and a new HS-GC-IMS prototype, which works at ramped temperature and presents a 10 cm drift tube. Both devices were compared in terms of resolution, precision and classification rates (CRs) using a 30 m non-polar capillary column. Our results suggested that the resolution in the chromatographic separation was improved using the device in which a ramped temperature can be performed in a shorter analysis time and the resolution in the ion mobility separation was also better. The repeatability values (RSD) for the standards quality control were lower than 10% in both cases. Moreover, as revealed in the olive oil 2D-maps, a higher number of markers were detected by the isothermal HS-GC-IMS (91) than that for the ramped temperature device (76), probably explained by the different sensitivity of both devices. These markers were used to build chemometric models based on orthogonal partial least squares-discriminant analysis. The olive oil samples in the validation set could be classified into extra virgin, virgin and lampante, defective and non-defective, as well as edible and non-edible with CRs ranging from 83 to 100%. In order to improve the resolution, a 60 m non-polar column was used in the ramped temperature HS-GC-IMS and enabled an increase in the visualized markers to 128, but it required a longer analysis time. The repeatability values were also lower than 10% and the CRs were improved (94–100%). Finally, 21, 22 and 25 olive oil aroma compounds were identified using the isothermal (30 m column) and the ramped temperature HS-GC-IMS with 30 and 60 m columns, respectively. Although some of these markers may give clues about the olive oil category, the chemometrics processing approach offers an objective tool for a robust classification and it is easily transferable to the industry. Highlights: Two HS-GC-IMS with different technical characteristics were compared. The adequacy of two HS-GC-IMS devices for olive oil classification was demonstrated. Discriminant models were built by OPLS-DA with classification rates up to 100%. 34 markers were characterized, comprising 25 compounds and various ionic species. 128 markers were grouped in function of their behavior between olive oils classes. … (more)
- Is Part Of:
- Food control. Volume 98(2019)
- Journal:
- Food control
- Issue:
- Volume 98(2019)
- Issue Display:
- Volume 98, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 98
- Issue:
- 2019
- Issue Sort Value:
- 2019-0098-2019-0000
- Page Start:
- 82
- Page End:
- 93
- Publication Date:
- 2019-04
- Subjects:
- Central composite design -- Chemometrics -- Ion mobility spectrometry -- Olive oil grading -- Olive oil aroma -- Panel test
Food -- Quality -- Periodicals
Food -- Analysis -- Periodicals
Food handling -- Periodicals
Food industry and trade -- Quality control -- Periodicals
Aliments -- Industrie et commerce -- Qualité -- Contrôle -- Périodiques
Aliments -- Qualité -- Périodiques
Aliments -- Analyse -- Périodiques
Hygiène alimentaire -- Périodiques
Food -- Analysis
Food handling
Food -- Quality
Periodicals
Electronic journals
664.07 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09567135 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.foodcont.2018.11.001 ↗
- Languages:
- English
- ISSNs:
- 0956-7135
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3977.291500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21492.xml