Determination of metmyoglobin in cooked tan mutton using Vis/NIR hyperspectral imaging system. Issue 5 (18th April 2020)
- Record Type:
- Journal Article
- Title:
- Determination of metmyoglobin in cooked tan mutton using Vis/NIR hyperspectral imaging system. Issue 5 (18th April 2020)
- Main Title:
- Determination of metmyoglobin in cooked tan mutton using Vis/NIR hyperspectral imaging system
- Authors:
- Yuan, Ruirui
Liu, Guishan
He, Jianguo
Ma, Chao
Cheng, Lijuan
Fan, Naiyun
Ban, Jingjing
Li, Yue
Sun, Yourui - Abstract:
- Abstract : Abstract: In this study, the ENVI 4.6 software was used to obtain the spectral reflection value of samples. The outlier samples were eliminated by the Monte Carlo method, and then SPXY (sample set partitioning based on be x – y distances) was used to divide the calibration set and prediction set. The spectral images were pretreated and characteristic wavelengths were extracted. The spectral models of full and pretreated spectra and characteristic bands were established by partial least squares regression (PLSR) and principle component regression (PCR), and the optimal modeling combination was selected. The results showed that the modeling effect of the original spectrum was the best. In full‐PLSR model, the determination coefficient of the calibration set (Rc 2 ), the determination coefficient of prediction set (Rp 2 ), and the determination coefficient of interactive verification set (Rcv 2 ) were 0.8804, 0.7375, and 0.7422, and root‐mean‐square error of calibration set (RMSEC), root‐mean‐square error of prediction (RMSEP), and root mean square error of interactive validation set (RMSECV) were 2.3630, 2.9607, and 3.4209, respectively. PLSR and PCR models were established to obtain the optimal models of CARS‐PLSR and PCR‐PLSR. In the CARS‐PLSR model, the Rc 2, Rp 2, and Rcv 2 were 0.9135, 0.7654, and 0.8171, respectively, while RMSEC, RMSEP, and RMSECV were 2.0275, 2.9306, and 2.9262, respectively. In the iRF‐PCR model, Rc 2, Rp 2, and Rcv 2 were 0.7952, 0.7372,Abstract : Abstract: In this study, the ENVI 4.6 software was used to obtain the spectral reflection value of samples. The outlier samples were eliminated by the Monte Carlo method, and then SPXY (sample set partitioning based on be x – y distances) was used to divide the calibration set and prediction set. The spectral images were pretreated and characteristic wavelengths were extracted. The spectral models of full and pretreated spectra and characteristic bands were established by partial least squares regression (PLSR) and principle component regression (PCR), and the optimal modeling combination was selected. The results showed that the modeling effect of the original spectrum was the best. In full‐PLSR model, the determination coefficient of the calibration set (Rc 2 ), the determination coefficient of prediction set (Rp 2 ), and the determination coefficient of interactive verification set (Rcv 2 ) were 0.8804, 0.7375, and 0.7422, and root‐mean‐square error of calibration set (RMSEC), root‐mean‐square error of prediction (RMSEP), and root mean square error of interactive validation set (RMSECV) were 2.3630, 2.9607, and 3.4209, respectively. PLSR and PCR models were established to obtain the optimal models of CARS‐PLSR and PCR‐PLSR. In the CARS‐PLSR model, the Rc 2, Rp 2, and Rcv 2 were 0.9135, 0.7654, and 0.8171, respectively, while RMSEC, RMSEP, and RMSECV were 2.0275, 2.9306, and 2.9262, respectively. In the iRF‐PCR model, Rc 2, Rp 2, and Rcv 2 were 0.7952, 0.7372, and 0.7280, respectively, while RMSEC, RMSEP, and RMSECV were 3.0207, 2.8278, and 3.4288, respectively. This study has demonstrated that visible and near‐infrared hyperspectral imaging system can rapidly predict the content of metmyoglobin in cooked tan mutton. Practical Application: This study has demonstrated that visible and near‐infrared (Vis/NIR) hyperspectral imaging system can rapidly predict the content of MetMb in cooked tan mutton. With the advantages of nondestructive, rapid, real‐time, Vis/NIR, hyperspectral imaging system can be widely expanded and applied to the detection of myoglobin in meat to evaluate the color of meat. … (more)
- Is Part Of:
- Journal of food science. Volume 85:Issue 5(2020)
- Journal:
- Journal of food science
- Issue:
- Volume 85:Issue 5(2020)
- Issue Display:
- Volume 85, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 85
- Issue:
- 5
- Issue Sort Value:
- 2020-0085-0005-0000
- Page Start:
- 1403
- Page End:
- 1410
- Publication Date:
- 2020-04-18
- Subjects:
- competitive adaptive reweighted sampling -- hyperspectral imaging -- metmyoglobin -- partial least squares regression -- tan mutton
Food -- Periodicals
Food -- Research -- Periodicals
Food -- Periodicals
Research -- Periodicals
Levensmiddelen
Voeding
664 - Journal URLs:
- http://www.confex2.com/ift/JFSonline8lD4ycqbCLoA/index.html ↗
http://www.ift.org/cms/ ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1750-3841 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwellpublishing.com/journal.asp?ref=0022-1147&site=1 ↗ - DOI:
- 10.1111/1750-3841.15137 ↗
- Languages:
- English
- ISSNs:
- 0022-1147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4984.560000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13265.xml