Identification and quantification of cereulide in cow's milk using liquid chromatography-tandem mass spectrometry. Issue 12 (2nd December 2018)
- Record Type:
- Journal Article
- Title:
- Identification and quantification of cereulide in cow's milk using liquid chromatography-tandem mass spectrometry. Issue 12 (2nd December 2018)
- Main Title:
- Identification and quantification of cereulide in cow's milk using liquid chromatography-tandem mass spectrometry
- Authors:
- Koike, Hiroshi
Kanda, Maki
Hayashi, Hiroshi
Matsushima, Yoko
Ohba, Yumi
Nakagawa, Yukiko
Nagano, Chieko
Sekimura, Kotaro
Hirai, Akihiko
Shindo, Tetsuya
Kamiie, Junichi
Sasamoto, Takeo
Hashimoto, Tsuneo - Abstract:
- ABSTRACT: In this study, the presence of cereulide in cow's milk was identified and quantified using our validated method with liquid chromatography-tandem mass spectrometry. Cereulide was concentrated using protein acid-precipitation and extracted from the precipitate by using acetonitrile twice. The combination of protein acid-precipitation and extraction sufficiently eliminated the matrix compounds from the milk and a further clean-up step utilising solid-phase extraction could be omitted. For robustly measuring the samples and keeping the MS devices clean, the extraction solution was diluted 10-fold using methanol. Owing to the minimisation of the interferences caused by fragmentation patterns, multiple reaction monitoring information-dependent acquisition-enhanced product ion spectra enabled the characterisation and identification of cereulide. Besides the matrix effect (−4%), an external solvent calibration curve was adapted for accurate quantification. The method was validated using fortified recovery tests, at two concentrations (10 and 50 µg kg −1 ), using three samples daily on five different days based on the Japanese guidelines. This new method exhibited good accuracy ranging from 91% to 94%. The relative standard deviations of repeatability ranged from 2% to 5%, and the relative standard deviation of within-laboratory reproducibility ranged from 5% to 6%. These standard deviations satisfied the criteria for the Japanese validation guidelines. The limit ofABSTRACT: In this study, the presence of cereulide in cow's milk was identified and quantified using our validated method with liquid chromatography-tandem mass spectrometry. Cereulide was concentrated using protein acid-precipitation and extracted from the precipitate by using acetonitrile twice. The combination of protein acid-precipitation and extraction sufficiently eliminated the matrix compounds from the milk and a further clean-up step utilising solid-phase extraction could be omitted. For robustly measuring the samples and keeping the MS devices clean, the extraction solution was diluted 10-fold using methanol. Owing to the minimisation of the interferences caused by fragmentation patterns, multiple reaction monitoring information-dependent acquisition-enhanced product ion spectra enabled the characterisation and identification of cereulide. Besides the matrix effect (−4%), an external solvent calibration curve was adapted for accurate quantification. The method was validated using fortified recovery tests, at two concentrations (10 and 50 µg kg −1 ), using three samples daily on five different days based on the Japanese guidelines. This new method exhibited good accuracy ranging from 91% to 94%. The relative standard deviations of repeatability ranged from 2% to 5%, and the relative standard deviation of within-laboratory reproducibility ranged from 5% to 6%. These standard deviations satisfied the criteria for the Japanese validation guidelines. The limit of quantification (LOQ) was estimated to be 2 μg kg −1 . On the product ion spectra at the LOQ level, the library match was satisfactory with a purity fit value of >70%. The method was applied to 14 raw milk and three milk samples pasteurised using the low-temperature, long-time process and collected in Tokyo. None of the samples was found to contain the target toxin. … (more)
- Is Part Of:
- Food additives & contaminants. Volume 35:Issue 12(2018)
- Journal:
- Food additives & contaminants
- Issue:
- Volume 35:Issue 12(2018)
- Issue Display:
- Volume 35, Issue 12 (2018)
- Year:
- 2018
- Volume:
- 35
- Issue:
- 12
- Issue Sort Value:
- 2018-0035-0012-0000
- Page Start:
- 2424
- Page End:
- 2433
- Publication Date:
- 2018-12-02
- Subjects:
- Cereulide -- cow's milk -- external solvent calibration curve -- liquid chromatography-tandem mass spectrometry -- product ion spectra
Food additives -- Periodicals
Food contamination -- Periodicals
664.06 - Journal URLs:
- http://www.tandfonline.com/ ↗
- DOI:
- 10.1080/19440049.2018.1544722 ↗
- Languages:
- English
- ISSNs:
- 1944-0049
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3977.002300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11746.xml