Poor 'Real-Life' Negative Predictive Value of Cross-Sectional Imaging in Obstructive Jaundice. Issue 7 (2014)
- Record Type:
- Journal Article
- Title:
- Poor 'Real-Life' Negative Predictive Value of Cross-Sectional Imaging in Obstructive Jaundice. Issue 7 (2014)
- Main Title:
- Poor 'Real-Life' Negative Predictive Value of Cross-Sectional Imaging in Obstructive Jaundice
- Authors:
- Brunson, Brian A
Hawes, Robert
Hoffman, Brenda
Vela, Stacie
Romagnuolo, Joseph - Abstract:
- Abstract : BACKGROUND: Cross-sectional imaging remains the first-line test for obstructive jaundice despite high miss rates for pancreatobiliary tumours. Improvements in resolution and slice thickness of spiral computed tomography/magnetic resonance imaging/magnetic resonance cholangiopancreatography promised to increase accuracy. OBJECTIVE: To assess whether the post-test probability of neoplasm is truly altered by the presence or absence of a mass on computed tomography/magnetic resonance imaging in obstructive jaundice. METHODS: The institutional endoscopic ultrasound (EUS) database was retrospectively reviewed to stratify patients presenting to EUS over a two-year period for obstructive jaundice (suspicious for malignancy) according to their pre-EUS imaging results. The primary analysis involved the calculation of the positive predictive value and negative predictive value (NPV) of imaging with 95% binomial CIs. Test performance of EUS/fine-needle aspiration (FNA) was also calculated. Final diagnosis was determined by positive cytology/histology; negative EUS was supplemented by clinical follow-up. RESULTS: The positive predictive value (n=51) and NPV (n=53) of pre-EUS imaging was 98% (95% CI 90% to 100%) and 9% (95% CI 3% to 21%), respectively (accuracy 53%), with post-test suspicion of malignancy similar between imaging-positive and -negative groups. EUS demonstrated a mass in 96% of imaging-positive cases versus 85% in imaging-negative cases (exact P=0.09). MalignantAbstract : BACKGROUND: Cross-sectional imaging remains the first-line test for obstructive jaundice despite high miss rates for pancreatobiliary tumours. Improvements in resolution and slice thickness of spiral computed tomography/magnetic resonance imaging/magnetic resonance cholangiopancreatography promised to increase accuracy. OBJECTIVE: To assess whether the post-test probability of neoplasm is truly altered by the presence or absence of a mass on computed tomography/magnetic resonance imaging in obstructive jaundice. METHODS: The institutional endoscopic ultrasound (EUS) database was retrospectively reviewed to stratify patients presenting to EUS over a two-year period for obstructive jaundice (suspicious for malignancy) according to their pre-EUS imaging results. The primary analysis involved the calculation of the positive predictive value and negative predictive value (NPV) of imaging with 95% binomial CIs. Test performance of EUS/fine-needle aspiration (FNA) was also calculated. Final diagnosis was determined by positive cytology/histology; negative EUS was supplemented by clinical follow-up. RESULTS: The positive predictive value (n=51) and NPV (n=53) of pre-EUS imaging was 98% (95% CI 90% to 100%) and 9% (95% CI 3% to 21%), respectively (accuracy 53%), with post-test suspicion of malignancy similar between imaging-positive and -negative groups. EUS demonstrated a mass in 96% of imaging-positive cases versus 85% in imaging-negative cases (exact P=0.09). Malignant or suspicious FNA cytology was obtained with EUS in 92% of the imaging-positive group, and 62% of the imaging-negative group (75% of subgroup with FNA) (P<0.001). CONCLUSION: Lack of a definite mass on pre-EUS imaging had low NPV, and was clearly not sufficiently accurate or reassuring in this clinical setting. In suspicious obstructive jaundice, EUS with FNA has a high diagnostic yield regardless of the findings of pre-EUS cross-sectional imaging and, as such, EUS may be a more reasonable first-line test in this high-suspicion setting. … (more)
- Is Part Of:
- Canadian journal of gastroenterology & hepatology. Volume 28:Issue 7(2014)
- Journal:
- Canadian journal of gastroenterology & hepatology
- Issue:
- Volume 28:Issue 7(2014)
- Issue Display:
- Volume 28, Issue 7 (2014)
- Year:
- 2014
- Volume:
- 28
- Issue:
- 7
- Issue Sort Value:
- 2014-0028-0007-0000
- Page Start:
- 385
- Page End:
- 390
- Publication Date:
- 2014
- Subjects:
- CT -- Diagnostic test accuracy -- EUS -- MRI -- Obstructive jaundice -- Pancreatic cancer -- Predictive value
Digestive organs -- Diseases -- Periodicals
Gastroenterology -- Periodicals
Digestive organs -- Diseases
Gastroenterology
Canada
Digestive System Diseases -- Periodicals
Gastroenterology -- Periodicals
Periodicals
Electronic journals
Fulltext
Internet Resources
Periodicals
616.3 - Journal URLs:
- https://www.hindawi.com/journals/cjgh/ ↗
http://bibpurl.oclc.org/web/74585 ↗
https://www.ncbi.nlm.nih.gov/pmc/journals/2438/ ↗
http://search.proquest.com/publication/2032234 ↗
http://resolver.library.ualberta.ca/resolver?ctx_enc=info%3Aofi%2Fenc%3AUTF-8&ctx_ver=Z39.88-2004&rfr_id=info%3Asid%2Fualberta.ca%3Aopac&rft.genre=journal&rft.object_id=2670000000550207&rft.issn=2291-2789&rft.eissn=2291-2797&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&url_ctx_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Actx&url_ver=Z39.88-2004 ↗
http://resolver.lrc.macewan.ca/macewan?url%5Fver=Z39.88-2004&ctx%5Fver=Z39.88-2004&ctx%5Fenc=info:ofi/enc:UTF-8&rfr%5Fid=info:sid/sfxit.com:opac%5F856&url%5Fctx%5Ffmt=info:ofi/fmt:kev:mtx:ctx&sfx.ignore%5Fdate%5Fthreshold=1&rft.object%5Fid=2670000000550207&svc%5Fval%5Ffmt=info:ofi/fmt:kev:mtx:sch%5Fsvc& ↗ - DOI:
- 10.1155/2014/797960 ↗
- Languages:
- English
- ISSNs:
- 2291-2789
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 25897.xml