Examining the Accuracy of the Polar A360 Monitor. Issue 8 (August 2021)
- Record Type:
- Journal Article
- Title:
- Examining the Accuracy of the Polar A360 Monitor. Issue 8 (August 2021)
- Main Title:
- Examining the Accuracy of the Polar A360 Monitor
- Authors:
- Rider, Brian C.
Conger, Scott A.
Ditzenberger, Grace L.
Besteman, Summer S.
Bouret, Claire M.
Coughlin, Adam M. - Abstract:
- Abstract : Abstract: Rider, BC, Conger, SA, Ditzenberger, GL, Besteman, SS, Bouret, CM, and Coughlin, AM. Examining the accuracy of the Polar A360 monitor. J Strength Cond Res 35(8): 2165–2169, 2021—The purpose of this study was to determine the accuracy of the Polar A360 heart rate (HR) monitor during periods of rest, walking/running, and active/passive recovery from exercise. Thirty collegiate athletes (women n = 15 and men n = 15) wore an A360 monitor and a previously validated chest HR monitor (Polar RS400) that served as the criterion measurement across a range of resting and walking/running intensities. First, subjects rested in a supine, seated, and standing position. Next, each subject walked on a treadmill at 1.6 kilometers per hour (kph). Speed was increased by 1.6 kph every 2 minutes until volitional fatigue. Then, subjects walked at 4.8 kph followed by a seated recovery stage. Heart rate was recorded in 30-second increments. Total mean difference in HR readings, percent accuracy, and intraclass correlation coefficient (ICC) analysis established the level of agreement between devices. Bland-Altman plots and a regression were used to examine the agreement between devices. The A360 demonstrated a strong correlation with the RS400 ( r 2 = 0.98) across time points. The analysis of variance with repeated measures indicated an overall significant difference ( p < 0.001) between devices. The A360 significantly underestimated HR during the 6.4-kph speed only ( p < 0.05)Abstract : Abstract: Rider, BC, Conger, SA, Ditzenberger, GL, Besteman, SS, Bouret, CM, and Coughlin, AM. Examining the accuracy of the Polar A360 monitor. J Strength Cond Res 35(8): 2165–2169, 2021—The purpose of this study was to determine the accuracy of the Polar A360 heart rate (HR) monitor during periods of rest, walking/running, and active/passive recovery from exercise. Thirty collegiate athletes (women n = 15 and men n = 15) wore an A360 monitor and a previously validated chest HR monitor (Polar RS400) that served as the criterion measurement across a range of resting and walking/running intensities. First, subjects rested in a supine, seated, and standing position. Next, each subject walked on a treadmill at 1.6 kilometers per hour (kph). Speed was increased by 1.6 kph every 2 minutes until volitional fatigue. Then, subjects walked at 4.8 kph followed by a seated recovery stage. Heart rate was recorded in 30-second increments. Total mean difference in HR readings, percent accuracy, and intraclass correlation coefficient (ICC) analysis established the level of agreement between devices. Bland-Altman plots and a regression were used to examine the agreement between devices. The A360 demonstrated a strong correlation with the RS400 ( r 2 = 0.98) across time points. The analysis of variance with repeated measures indicated an overall significant difference ( p < 0.001) between devices. The A360 significantly underestimated HR during the 6.4-kph speed only ( p < 0.05) (effect size 0.26). The greatest percent accuracy occurred during rest (91%) and recovery (90%). An ICC of 0.98 ( SEM : 0.35) demonstrates a strong level of agreement between devices. The A360 is accurate at rest and during various walking and running speeds and thus is a device that can be used with confidence by athletes for specific training purposes. Future research should examine accuracy during weight training and other sport-specific activities. … (more)
- Is Part Of:
- Journal of strength and conditioning research. Volume 35:Issue 8(2021)
- Journal:
- Journal of strength and conditioning research
- Issue:
- Volume 35:Issue 8(2021)
- Issue Display:
- Volume 35, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 35
- Issue:
- 8
- Issue Sort Value:
- 2021-0035-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- watch -- heart rate -- photoplethysmography
Physical education and training -- Periodicals
Weight training -- Physiological aspects -- Periodicals
Physical fitness -- Periodicals
613.7 - Journal URLs:
- http://journals.lww.com/nsca-jscr/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1519/JSC.0000000000003136 ↗
- Languages:
- English
- ISSNs:
- 1064-8011
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5066.873700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25589.xml