Mechanical stress distribution and risk assessment of 110 kV GIS insulator considering Al2O3 settlement. Issue 1 (4th February 2019)
- Record Type:
- Journal Article
- Title:
- Mechanical stress distribution and risk assessment of 110 kV GIS insulator considering Al2O3 settlement. Issue 1 (4th February 2019)
- Main Title:
- Mechanical stress distribution and risk assessment of 110 kV GIS insulator considering Al2O3 settlement
- Authors:
- Liang, Hucheng
Du, Boxue
Li, Jin
Wang, Zehua - Abstract:
- Abstract : The growing application of gas insulated switchgear (GIS) in electric power system asks for higher reliability of epoxy (EP) insulators, thus it is important to seek effective methods to improve the operating reliability of GIS insulators. On the basis of the 110 kV GIS insulator, this study studied the aluminium oxide (Al2 O3 ) settlement in the curing process and the stress distribution of the horizontally laid GIS. Besides, the risk coefficient was defined to evaluate the operating reliability of insulators laid by different methods ( I–V ). Some conclusions are shown below: the Al2 O3 settlement in the curing process causes the insulator density to have a large variation from 2.13 to 2.32 g/cm 3 . The Al2 O3 content has a great influence on the mechanical performances of EP/Al2 O3 system. The first principle stress is localised on the upper interface between the insulator and the conductor, which is the main threat to the mechanical damage of insulator. The laying method V appears to be optimal with a pretty low risk coefficient of 31.5. In actual application, for the horizontally laid GIS, the insulator should be laid with the mould gate downward to improve its mechanical reliability.
- Is Part Of:
- High voltage. Volume 4:Issue 1(2019)
- Journal:
- High voltage
- Issue:
- Volume 4:Issue 1(2019)
- Issue Display:
- Volume 4, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 4
- Issue:
- 1
- Issue Sort Value:
- 2019-0004-0001-0000
- Page Start:
- 65
- Page End:
- 71
- Publication Date:
- 2019-02-04
- Subjects:
- moulding -- compressive strength -- Poisson ratio -- gas insulated switchgear -- curing -- tensile strength -- alumina -- reliability -- insulators
gas insulated switchgear -- electric power system -- epoxy insulators -- operating reliability -- GIS insulators -- curing process -- laying method -- voltage 110.0 kV -- Al2O3 -- risk assessment -- mechanical stress distribution -- mechanical reliability -- insulator density
High voltages -- Periodicals
621.3191 - Journal URLs:
- http://ieeexplore.ieee.org/Xplore/home.jsp ↗
https://ietresearch.onlinelibrary.wiley.com/journal/23977264 ↗
http://digital-library.theiet.org/content/journals/hve ↗ - DOI:
- 10.1049/hve.2018.5057 ↗
- Languages:
- English
- ISSNs:
- 2397-7264
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4307.369710
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23472.xml