A novel sensitive electrochemical method for the detection of ractopamine in meat food via polycitrulline-modified electrode. Issue 9 (1st September 2020)
- Record Type:
- Journal Article
- Title:
- A novel sensitive electrochemical method for the detection of ractopamine in meat food via polycitrulline-modified electrode. Issue 9 (1st September 2020)
- Main Title:
- A novel sensitive electrochemical method for the detection of ractopamine in meat food via polycitrulline-modified electrode
- Authors:
- Ma, Xinying
Lv, Huiping
Zhu, Qi
Chen, Meifeng
Wang, Yilei
Li, Fenghai - Abstract:
- ABSTRACT: In this paper we report the modification with citrulline of the surface of a glassy carbon electrode (GCE) through cyclic voltammetry to prepare a polycitrulline-modified electrode (PCit/GCE). The electrochemical behaviour of ractopamine on this PCit/GCE was then investigated by cyclic voltammetry, to establish a novel electrochemical method for the detection of ractopamine residues in animal tissue. The optimum preparation conditions for the modified electrode were found to include a polymerisation solution pH of 6.8. The cyclic voltammetry required 12 scan cycles at a scan rate of 40 mV/s with a potential range of −1.6 to 2.3 V. The optimum conditions to determine ractopamine were in a solution of pH 6.0 with cyclic voltammetry performed at a scan rate of 60 mV/s and a potential range of 0.4 to 1.0 V. To analyse meat, the tissue sample was extracted with ethanol, filtered, evaporated to dryness and diluted with phosphate buffered saline at pH of 6.0 before being analysed in the electrochemical cell. The limit of detection of the new method for ractopamine was 1.0 ng/g and the correlation coefficient (R) was 0.9991 in the concentration range of 140–5410 ng/g. Ractopamine residue levels in spiked beef and mutton samples were detected by the modified electrode and the recovery was in the range of 96%-101%, giving results consistent with a validated HPLC method. This study provides a new method for detection and quantification of ractopamine residues in animalABSTRACT: In this paper we report the modification with citrulline of the surface of a glassy carbon electrode (GCE) through cyclic voltammetry to prepare a polycitrulline-modified electrode (PCit/GCE). The electrochemical behaviour of ractopamine on this PCit/GCE was then investigated by cyclic voltammetry, to establish a novel electrochemical method for the detection of ractopamine residues in animal tissue. The optimum preparation conditions for the modified electrode were found to include a polymerisation solution pH of 6.8. The cyclic voltammetry required 12 scan cycles at a scan rate of 40 mV/s with a potential range of −1.6 to 2.3 V. The optimum conditions to determine ractopamine were in a solution of pH 6.0 with cyclic voltammetry performed at a scan rate of 60 mV/s and a potential range of 0.4 to 1.0 V. To analyse meat, the tissue sample was extracted with ethanol, filtered, evaporated to dryness and diluted with phosphate buffered saline at pH of 6.0 before being analysed in the electrochemical cell. The limit of detection of the new method for ractopamine was 1.0 ng/g and the correlation coefficient (R) was 0.9991 in the concentration range of 140–5410 ng/g. Ractopamine residue levels in spiked beef and mutton samples were detected by the modified electrode and the recovery was in the range of 96%-101%, giving results consistent with a validated HPLC method. This study provides a new method for detection and quantification of ractopamine residues in animal tissue. Graphical Abstract: uf0001 … (more)
- Is Part Of:
- Food additives & contaminants. Volume 37:Issue 9(2020)
- Journal:
- Food additives & contaminants
- Issue:
- Volume 37:Issue 9(2020)
- Issue Display:
- Volume 37, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 37
- Issue:
- 9
- Issue Sort Value:
- 2020-0037-0009-0000
- Page Start:
- 1459
- Page End:
- 1466
- Publication Date:
- 2020-09-01
- Subjects:
- Citrulline -- glassy carbon electrode -- modified electrode -- ractopamine
Food additives -- Periodicals
Food contamination -- Periodicals
664.06 - Journal URLs:
- http://www.tandfonline.com/ ↗
- DOI:
- 10.1080/19440049.2020.1769867 ↗
- Languages:
- English
- ISSNs:
- 1944-0049
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3977.002300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22715.xml