Construct Validity, Test-Retest Reliability, and Repeatability of Performance Variables Using a Flywheel Resistance Training Device. Issue 11 (November 2020)
- Record Type:
- Journal Article
- Title:
- Construct Validity, Test-Retest Reliability, and Repeatability of Performance Variables Using a Flywheel Resistance Training Device. Issue 11 (November 2020)
- Main Title:
- Construct Validity, Test-Retest Reliability, and Repeatability of Performance Variables Using a Flywheel Resistance Training Device
- Authors:
- Bollinger, Lance M.
Brantley, Jason T.
Tarlton, Justin K.
Baker, Paul A.
Seay, Rebekah F.
Abel, Mark G. - Abstract:
- Abstract : Abstract: Bollinger, LM, Brantley, JT, Tarlton, JK, Baker, PA, Seay, RF, and Abel, MG. Construct validity, test-retest reliability, and repeatability of performance variables using a flywheel resistance training device. J Strength Cond Res 34(11): 3149–3156, 2020—Power production is highly associated with physical performance; however, the ability to quantitatively measure power output during resistance exercise is lacking. The purpose of this study was to determine the validity and test-retest reliability of flywheel-based performance testing. Twelve young, resistance trained subjects completed 2 bouts of resistance exercise using a flywheel resistance training device (Exxentric kbox 4 Pro). Each session consisted of 3 sets of 3 exercise (bent-over row, Romanian deadlift, and biceps curl) with varying moments of inertia (0.050, 0.075, and 0.100 kg·m 2, respectively) in random order. Each set consisted of 5 maximal effort repetitions with 3-minute recovery between sets. Average power, peak concentric and eccentric power, average force, average speed, and total work for each set were recorded. Regression analysis revealed a near-perfect relationship between measured and predicted power, force, and work at given workloads. Pearson's r between trials 1 and 2 revealed good (≥0.70) to excellent (≥0.90) test-retest reliability for all outcomes with the exception of peak eccentric power for biceps curls ( r = 0.69), which narrowly missed the cutoff for acceptableAbstract : Abstract: Bollinger, LM, Brantley, JT, Tarlton, JK, Baker, PA, Seay, RF, and Abel, MG. Construct validity, test-retest reliability, and repeatability of performance variables using a flywheel resistance training device. J Strength Cond Res 34(11): 3149–3156, 2020—Power production is highly associated with physical performance; however, the ability to quantitatively measure power output during resistance exercise is lacking. The purpose of this study was to determine the validity and test-retest reliability of flywheel-based performance testing. Twelve young, resistance trained subjects completed 2 bouts of resistance exercise using a flywheel resistance training device (Exxentric kbox 4 Pro). Each session consisted of 3 sets of 3 exercise (bent-over row, Romanian deadlift, and biceps curl) with varying moments of inertia (0.050, 0.075, and 0.100 kg·m 2, respectively) in random order. Each set consisted of 5 maximal effort repetitions with 3-minute recovery between sets. Average power, peak concentric and eccentric power, average force, average speed, and total work for each set were recorded. Regression analysis revealed a near-perfect relationship between measured and predicted power, force, and work at given workloads. Pearson's r between trials 1 and 2 revealed good (≥0.70) to excellent (≥0.90) test-retest reliability for all outcomes with the exception of peak eccentric power for biceps curls ( r = 0.69), which narrowly missed the cutoff for acceptable reliability. Bland-Altman plots revealed small (approximately 5–15%), but statistically significant bias between the 2 trials for some measures. Coefficient of repeatability for all outcomes was relatively high, indicating poor repeatability. Flywheel-based performance testing provides valid data. However, reliability varies between individual lifts and specific outcomes. Given the poor repeatability between trials, it is likely that subjects who are unaccustomed to this modality may require multiple testing sessions or a thorough familiarization period to ensure accurate measures of power, force, speed, and work during flywheel-based performance testing. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Journal of strength and conditioning research. Volume 34:Issue 11(2020)
- Journal:
- Journal of strength and conditioning research
- Issue:
- Volume 34:Issue 11(2020)
- Issue Display:
- Volume 34, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 34
- Issue:
- 11
- Issue Sort Value:
- 2020-0034-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11
- Subjects:
- inertial training -- power -- exercise testing -- work
Physical education and training -- Periodicals
Weight training -- Physiological aspects -- Periodicals
Physical fitness -- Periodicals
613.7 - Journal URLs:
- http://journals.lww.com/nsca-jscr/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1519/JSC.0000000000002647 ↗
- Languages:
- English
- ISSNs:
- 1064-8011
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5066.873700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21392.xml