A UV/Vis spectrophotometric methodology for quality control of stevia-based extracts in the food industry. (July 2022)
- Record Type:
- Journal Article
- Title:
- A UV/Vis spectrophotometric methodology for quality control of stevia-based extracts in the food industry. (July 2022)
- Main Title:
- A UV/Vis spectrophotometric methodology for quality control of stevia-based extracts in the food industry
- Authors:
- Tsotsou, Georgia Eleni
Potiriadi, Ioanna - Abstract:
- Abstract: This study established a methodology for quality control of stevia extracts in food industry where one, or a mixture of major stevia glycosides, rebausioside A and stevioside, are present. The methodology relies on pre-treatment to eliminate glucose that may be already present, prior to acid hydrolysis of stevia glycosides toward isosteviol plus glucose and ensuing released glucose quantification using the glucose oxidase/peroxidase coupled assay. Subsequent isosteviol isolation and concentration assessment using UV spectroscopy, permits the quantification of an average number of glucose molecules released per a generated molecule of isosteviol. The latter increases the assay specificity, allowing confirmatory assessment of stevia glycoside identity and purity. Favorable technical characteristics, satisfying international specifications for method validation, were determined for each individual assay (glycoside quantification by acid hydrolysis and isosteviol quantification) for rebaudioside A and stevioside: Standard curves were linear (R 2 ≥ 0.993 [R 2 ≥ 0.984 for the glucose/isosteviol quantification assay]) over a concentration range from approximately 10 −1 mg/mL for the acid assay and 3.0 mg/mL for the glucose/isosteviol assay up to at least 10 mg/mL glycoside. The CV% on all quality control levels was ≤6.33% for repeatability and ≤12.03% for intermediate precision. Bias was ≤±5.00% in all cases. Upon comparison with the gold standard LC/UV method for rebAAbstract: This study established a methodology for quality control of stevia extracts in food industry where one, or a mixture of major stevia glycosides, rebausioside A and stevioside, are present. The methodology relies on pre-treatment to eliminate glucose that may be already present, prior to acid hydrolysis of stevia glycosides toward isosteviol plus glucose and ensuing released glucose quantification using the glucose oxidase/peroxidase coupled assay. Subsequent isosteviol isolation and concentration assessment using UV spectroscopy, permits the quantification of an average number of glucose molecules released per a generated molecule of isosteviol. The latter increases the assay specificity, allowing confirmatory assessment of stevia glycoside identity and purity. Favorable technical characteristics, satisfying international specifications for method validation, were determined for each individual assay (glycoside quantification by acid hydrolysis and isosteviol quantification) for rebaudioside A and stevioside: Standard curves were linear (R 2 ≥ 0.993 [R 2 ≥ 0.984 for the glucose/isosteviol quantification assay]) over a concentration range from approximately 10 −1 mg/mL for the acid assay and 3.0 mg/mL for the glucose/isosteviol assay up to at least 10 mg/mL glycoside. The CV% on all quality control levels was ≤6.33% for repeatability and ≤12.03% for intermediate precision. Bias was ≤±5.00% in all cases. Upon comparison with the gold standard LC/UV method for rebA quantification, we demonstrated a very good agreement and acceptable bias (slope: 1.02, y-intercept: −0.73, R 2 : 0.994). Acid hydrolysis was tested successfully on commercial products, stevia extracts and commodity sweeteners, containing either of the two major glycosides. We demonstrated that the proposed methodology was able to distinguish between commercial samples containing pure rebaudioside A or stevioside alone and samples containing additional steviol glycosides in combination. When verifying glycoside content in binary mixtures of rebaudioside A and stevioside, bias was sufficiently low (<10%). The proposed methodology requires minimal equipment and expertise and is applicable to a significant percentage (approximately 50%) of all commercial stevia extracts and sweeteners. Our findings should provide a useful tool for stevia quality control, thus allowing an increase in the frequency and extent of testing, even in minimally equipped settings, while containing cost. Highlights: Hydrolysis-released glucose and isosteviol were validated for stevia quality control. Method confirms identity and purity in samples of rebaudioside A or stevioside alone. Method verifies composition in pure rebaudioside A/stevioside samples or their mixtures. The only specific photometric method as first-line approach in stevia quality control. … (more)
- Is Part Of:
- Food control. Volume 137(2022)
- Journal:
- Food control
- Issue:
- Volume 137(2022)
- Issue Display:
- Volume 137, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 137
- Issue:
- 2022
- Issue Sort Value:
- 2022-0137-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-07
- Subjects:
- Stevia glycoside quantification -- Quality control -- Isosteviol -- Rebaudioside A -- Stevioside
stev Stevioside -- rebA Rebaudioside A -- HK Hexokinase -- G6P-DH Glucose-6-phosphate Dehydrogenase -- GOD Glucose Oxidase -- POD Peroxidase -- WHO World Health Organization -- FAO Food and Agriculture Organization -- RSS Residual Sum of Squares -- m.p Melting Point -- QC Quality Control
Food -- Quality -- Periodicals
Food -- Analysis -- Periodicals
Food handling -- Periodicals
Food industry and trade -- Quality control -- Periodicals
Aliments -- Industrie et commerce -- Qualité -- Contrôle -- Périodiques
Aliments -- Qualité -- Périodiques
Aliments -- Analyse -- Périodiques
Hygiène alimentaire -- Périodiques
Food -- Analysis
Food handling
Food -- Quality
Periodicals
Electronic journals
664.07 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09567135 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.foodcont.2022.108932 ↗
- Languages:
- English
- ISSNs:
- 0956-7135
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3977.291500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21217.xml