Ultrasensitive microfluidic immunosensor with stir bar enrichment for point-of-care test of Staphylococcus aureus in foods triggered by DNAzyme-assisted click reaction. (1st June 2022)
- Record Type:
- Journal Article
- Title:
- Ultrasensitive microfluidic immunosensor with stir bar enrichment for point-of-care test of Staphylococcus aureus in foods triggered by DNAzyme-assisted click reaction. (1st June 2022)
- Main Title:
- Ultrasensitive microfluidic immunosensor with stir bar enrichment for point-of-care test of Staphylococcus aureus in foods triggered by DNAzyme-assisted click reaction
- Authors:
- Wang, Jiaqi
Tan, Lei
Bi, Wenchao
Shen, Haoyu
Li, Dengfeng
Yu, Zhenzhong
Gan, Ning - Abstract:
- Graphic abstract: Highlights: An immunosensor based on a microfluidic chip was developed for the point-of-care test of S. aureus with a LOD of 3 CFU/mL. The prepared yolk antibody presented strong specificity, high stability, and low cost. A triple signal amplification strategy was used, including the enrichment of the stir bar, the high copper loading of polydopamine nanoparticles, and the DNAzyme-assisted click reaction. The microfluidic chip was served as a sensitive and portable signal detection platform. Abstract: This work demonstrated an ultrasensitive and simple microfluidic immunosensor for point-of-care test of Staphylococcus aureus ( S. aureus ) based on the stir bar enrichment and DNAzyme-assisted click reaction. Initially, S. aureus was enriched by the 4-mercaptophenylboronic acid-functionalized stir bar. The yolk antibody (immunoglobulin Y) and copper-labeled polydopamine nanoparticles were then specifically conjugated with the captured target. The Cu(II) was released under acidic conditions and effectively catalyzed the copper-catalyzed azide-alkyne cycloaddition (CuAAC) between the alkyne group-labeled DNAzyme and the streptavidin–biotin-azido with the assistance of DNAzyme. Finally, the DNAzyme-streptavidin complexes were detected by microfluidic chips to quantify S. aureus . Under optimum conditions, this immunosensor showed good detection performances toward S. aureus within 10 to 2.5 × 10 4 CFU/mL with a limit of detection of 3 CFU/mL. Moreover, theGraphic abstract: Highlights: An immunosensor based on a microfluidic chip was developed for the point-of-care test of S. aureus with a LOD of 3 CFU/mL. The prepared yolk antibody presented strong specificity, high stability, and low cost. A triple signal amplification strategy was used, including the enrichment of the stir bar, the high copper loading of polydopamine nanoparticles, and the DNAzyme-assisted click reaction. The microfluidic chip was served as a sensitive and portable signal detection platform. Abstract: This work demonstrated an ultrasensitive and simple microfluidic immunosensor for point-of-care test of Staphylococcus aureus ( S. aureus ) based on the stir bar enrichment and DNAzyme-assisted click reaction. Initially, S. aureus was enriched by the 4-mercaptophenylboronic acid-functionalized stir bar. The yolk antibody (immunoglobulin Y) and copper-labeled polydopamine nanoparticles were then specifically conjugated with the captured target. The Cu(II) was released under acidic conditions and effectively catalyzed the copper-catalyzed azide-alkyne cycloaddition (CuAAC) between the alkyne group-labeled DNAzyme and the streptavidin–biotin-azido with the assistance of DNAzyme. Finally, the DNAzyme-streptavidin complexes were detected by microfluidic chips to quantify S. aureus . Under optimum conditions, this immunosensor showed good detection performances toward S. aureus within 10 to 2.5 × 10 4 CFU/mL with a limit of detection of 3 CFU/mL. Moreover, the satisfying detection results of real samples of animal origin also implied that this immunosensor owned great potential in practical applications. … (more)
- Is Part Of:
- Food chemistry. Volume 378(2022)
- Journal:
- Food chemistry
- Issue:
- Volume 378(2022)
- Issue Display:
- Volume 378, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 378
- Issue:
- 2022
- Issue Sort Value:
- 2022-0378-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06-01
- Subjects:
- Foodborne pathogen -- Microfluidic immunosensor -- Stir bar enrichment -- Copper-polydopamine nanoparticles -- DNAzyme -- Click reaction
Food -- Analysis -- Periodicals
Food -- Composition -- Periodicals
664 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03088146 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.foodchem.2022.132093 ↗
- Languages:
- English
- ISSNs:
- 0308-8146
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3977.284000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20664.xml