Critical comparison of direct analysis in real time orbitrap mass spectrometry (DART-Orbitrap MS) towards liquid chromatography mass spectrometry (LC-MS) for mycotoxin detection in cereal matrices. (February 2022)
- Record Type:
- Journal Article
- Title:
- Critical comparison of direct analysis in real time orbitrap mass spectrometry (DART-Orbitrap MS) towards liquid chromatography mass spectrometry (LC-MS) for mycotoxin detection in cereal matrices. (February 2022)
- Main Title:
- Critical comparison of direct analysis in real time orbitrap mass spectrometry (DART-Orbitrap MS) towards liquid chromatography mass spectrometry (LC-MS) for mycotoxin detection in cereal matrices
- Authors:
- Tsagkaris, A.S.
Hrbek, V.
Dzuman, Z.
Hajslova, J. - Abstract:
- Abstract: Foodstuffs contaminated by mycotoxins have been reported around the globe resulting in significant financial losses and health-threating cases due to dietary exposure. Commonly, two analytical approaches are used in mycotoxin analysis, namely screening bioanalytical methods such as immunoassays and confirmatory chromatographic analysis which are related to certain merits and challenges. In this study, to provide an alternative combining rapidness and unequivocal analyte identification, a direct analysis in real time ion source coupled to orbitrap mass spectrometry (DART-Orbitrap MS) method was developed and validated for the detection of 19 mycotoxins in cereal flour matrices. Excellent detectability expressed as the lowest calibration level (LCL) ranging between 25 μg kg −1 and 250 μg kg −1 depending on the analyte was achieved as well as satisfactory precision and trueness. To identify advantages and drawbacks of the in-house DART-Orbitrap MS method against the golden standard methods, a critical comparison towards liquid chromatography (LC) coupled to high and low resolution MS was performed. DART-Orbitrap MS high throughput and rapidity was revealed while LC-MS proved its superior detectability, which is of indispensable importance for mycotoxin regulatory control. In conclusion, the developed DART-Orbitrap MS method can be applied to intensify and accelerate the monitoring of specific mycotoxins in cereal matrices. Highlights: Rapid detection of 19 mycotoxinsAbstract: Foodstuffs contaminated by mycotoxins have been reported around the globe resulting in significant financial losses and health-threating cases due to dietary exposure. Commonly, two analytical approaches are used in mycotoxin analysis, namely screening bioanalytical methods such as immunoassays and confirmatory chromatographic analysis which are related to certain merits and challenges. In this study, to provide an alternative combining rapidness and unequivocal analyte identification, a direct analysis in real time ion source coupled to orbitrap mass spectrometry (DART-Orbitrap MS) method was developed and validated for the detection of 19 mycotoxins in cereal flour matrices. Excellent detectability expressed as the lowest calibration level (LCL) ranging between 25 μg kg −1 and 250 μg kg −1 depending on the analyte was achieved as well as satisfactory precision and trueness. To identify advantages and drawbacks of the in-house DART-Orbitrap MS method against the golden standard methods, a critical comparison towards liquid chromatography (LC) coupled to high and low resolution MS was performed. DART-Orbitrap MS high throughput and rapidity was revealed while LC-MS proved its superior detectability, which is of indispensable importance for mycotoxin regulatory control. In conclusion, the developed DART-Orbitrap MS method can be applied to intensify and accelerate the monitoring of specific mycotoxins in cereal matrices. Highlights: Rapid detection of 19 mycotoxins in cereal flour matrices using a DART-MS method. Fit-for-purpose results and excellent analytical performance were achieved. Critical comparison towards LC-MS revealed DART-MS potential in food control. … (more)
- Is Part Of:
- Food control. Volume 132(2022)
- Journal:
- Food control
- Issue:
- Volume 132(2022)
- Issue Display:
- Volume 132, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 132
- Issue:
- 2022
- Issue Sort Value:
- 2022-0132-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-02
- Subjects:
- Mycotoxins -- Emerging mycotoxins -- Direct analysis in real time -- High resolution mass spectrometry -- Low resolution mass spectrometry -- Cereals
Food -- Quality -- Periodicals
Food -- Analysis -- Periodicals
Food handling -- Periodicals
Food industry and trade -- Quality control -- Periodicals
Aliments -- Industrie et commerce -- Qualité -- Contrôle -- Périodiques
Aliments -- Qualité -- Périodiques
Aliments -- Analyse -- Périodiques
Hygiène alimentaire -- Périodiques
Food -- Analysis
Food handling
Food -- Quality
Periodicals
Electronic journals
664.07 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09567135 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.foodcont.2021.108548 ↗
- Languages:
- English
- ISSNs:
- 0956-7135
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3977.291500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20003.xml