P036: Sensitivity and false negatives in the use of a prehospital sepsis alert. (May 2020)
- Record Type:
- Journal Article
- Title:
- P036: Sensitivity and false negatives in the use of a prehospital sepsis alert. (May 2020)
- Main Title:
- P036: Sensitivity and false negatives in the use of a prehospital sepsis alert
- Authors:
- Sample, S.
Quinlan, D.
Willis, K.
Casement, D.
Lutz-Graul, K.
Welsford, M. - Abstract:
- Abstract : Introduction: Prehospital sepsis alerts assist paramedics in identifying patients with sepsis and in communicating this diagnosis to receiving facilities. Following the prospective implementation study of our regional systemic inflammatory response syndrome-based alert criteria (Alert), the purpose of this sub-study was to determine the cause of Alert false negatives (patients without an Alert that subsequently met sepsis criteria in the Emergency Department (ED)). Additionally, the sensitivity of the Alert for detecting sepsis was compared to the Quick Sequential Organ Failure Assessment (qSOFA) and Hamilton Early Warning Score (HEWS). Methods: This study was an additional analysis of the prospective Alert implementation study. Included patients were ≥ 18 years old, transported by a regional Emergency Medical Service and met severe sepsis or septic shock criteria (SS/SS, 2012 Surviving Sepsis Guidelines) in regional EDs in 2013. False negative patients were identified prospectively and reviewed by comparing paramedic determined Alert status to the retrospective application of the Alert criteria to Paramedic Call Report (PCR) data. The Alert sensitivity was first calculated from prospective data, then retrospective sensitivities of the Alert, qSOFA and HEWS were calculated by retrospectively applying these tools to PCRs, using ED diagnosis of SS/SS as reference standard. Results: In 2013, 229 patients met SS/SS criteria in the ED and had PCRs available; 115Abstract : Introduction: Prehospital sepsis alerts assist paramedics in identifying patients with sepsis and in communicating this diagnosis to receiving facilities. Following the prospective implementation study of our regional systemic inflammatory response syndrome-based alert criteria (Alert), the purpose of this sub-study was to determine the cause of Alert false negatives (patients without an Alert that subsequently met sepsis criteria in the Emergency Department (ED)). Additionally, the sensitivity of the Alert for detecting sepsis was compared to the Quick Sequential Organ Failure Assessment (qSOFA) and Hamilton Early Warning Score (HEWS). Methods: This study was an additional analysis of the prospective Alert implementation study. Included patients were ≥ 18 years old, transported by a regional Emergency Medical Service and met severe sepsis or septic shock criteria (SS/SS, 2012 Surviving Sepsis Guidelines) in regional EDs in 2013. False negative patients were identified prospectively and reviewed by comparing paramedic determined Alert status to the retrospective application of the Alert criteria to Paramedic Call Report (PCR) data. The Alert sensitivity was first calculated from prospective data, then retrospective sensitivities of the Alert, qSOFA and HEWS were calculated by retrospectively applying these tools to PCRs, using ED diagnosis of SS/SS as reference standard. Results: In 2013, 229 patients met SS/SS criteria in the ED and had PCRs available; 115 (50.2%) were male and median age [interquartile range] was 76.0 [63.0-84.0]. Of 229, 149 (65.0%) arrived in the ED without an Alert (false negatives) and 46 (30.9%) of these met Alert criteria retrospectively and were therefore missed by paramedics. Sensitivity of the Alert was 34.9% when applied by paramedics and 41.5% when applied retrospectively to PCRs. The retrospective sensitivities of the qSOFA and HEWS were 37.6% and 67.7%, respectively. Conclusion: In ED patients diagnosed with SS/SS who arrived with no Alert, the majority (69.1%) were missed by the Alert criteria, rather than by paramedic application of the tool. The Alert had a sensitivity of 34.9%. When applied retrospectively and compared to the Alert, qSOFA had similar sensitivity and HEWS had increased sensitivity. Future research should focus on deriving improved alerts or implementing those with higher accuracy, such as HEWS. … (more)
- Is Part Of:
- CJEM. Volume 22(2020)Supplement 1
- Journal:
- CJEM
- Issue:
- Volume 22(2020)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2020-0022-0001-0000
- Page Start:
- S77
- Page End:
- S77
- Publication Date:
- 2020-05
- Subjects:
- emergency medical services, -- pre-alert, -- sepsis
Emergency Treatment -- Periodicals
Emergency Medicine -- Periodicals
Emergency medical services -- Canada -- Periodicals
Medical emergencies -- Canada -- Periodicals
Emergency medical services
Medical emergencies
Canada
Periodicals
616.02505 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=CEM ↗
http://www.caep.ca/004.cjem-jcmu/004-00.cjem/004-01v.archives.htm#main ↗
http://link.springer.com/ ↗ - DOI:
- 10.1017/cem.2020.243 ↗
- Languages:
- English
- ISSNs:
- 1481-8035
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17245.xml