Influence of moisture on the interface charge of oil–pressboard composite insulation under DC voltage. Issue 1 (7th February 2018)
- Record Type:
- Journal Article
- Title:
- Influence of moisture on the interface charge of oil–pressboard composite insulation under DC voltage. Issue 1 (7th February 2018)
- Main Title:
- Influence of moisture on the interface charge of oil–pressboard composite insulation under DC voltage
- Authors:
- Qi, Bo
Jiao, Yanqiu
Gao, Chunjia
Zhang, Shuqi
Zhao, Xiaolin
Li, Chengrong - Abstract:
- Abstract : The distortion of the electric field in the oil–pressboard composite insulation caused by the accumulation of the interface charge is detrimental to both the insulation design and operation of converter transformers. The influence of moisture content on the surface charge accumulation of oil–pressboard insulation under DC voltage was studied in this study. In accordance with the Kerr electro‐optic effect, the electric field strengths in transformer oil and the surface charge density were acquired after applying the positive and negative DC voltages in three oil–pressboard insulation models with different moisture content, respectively. The resistivities of the oil and pressboard in three models, namely Model 1# with 3.8–4.2 ppm moisture in oil and 0.35–0.37% moisture in pressboard, Model 2# with 7.6–7.9 ppm moisture in oil and 0.79–0.82% moisture in pressboard and Model 3# with 14.9–15.4 ppm moisture in oil and 1.39–1.42% moisture in pressboard, was also measured. The results indicate that: (i) as negative charges in oil accumulated on the pressboard surface in a much greater speed than the positive ones, the electric field in transformer oil under negative DC voltage decreases more rapidly with time than that under positive DC voltage; (ii) the increase of the moisture content in both oil and pressboard, under either positive or negative DC voltage, leads to the decrease of both the electric field strength in transformer oil and the charge density with time; andAbstract : The distortion of the electric field in the oil–pressboard composite insulation caused by the accumulation of the interface charge is detrimental to both the insulation design and operation of converter transformers. The influence of moisture content on the surface charge accumulation of oil–pressboard insulation under DC voltage was studied in this study. In accordance with the Kerr electro‐optic effect, the electric field strengths in transformer oil and the surface charge density were acquired after applying the positive and negative DC voltages in three oil–pressboard insulation models with different moisture content, respectively. The resistivities of the oil and pressboard in three models, namely Model 1# with 3.8–4.2 ppm moisture in oil and 0.35–0.37% moisture in pressboard, Model 2# with 7.6–7.9 ppm moisture in oil and 0.79–0.82% moisture in pressboard and Model 3# with 14.9–15.4 ppm moisture in oil and 1.39–1.42% moisture in pressboard, was also measured. The results indicate that: (i) as negative charges in oil accumulated on the pressboard surface in a much greater speed than the positive ones, the electric field in transformer oil under negative DC voltage decreases more rapidly with time than that under positive DC voltage; (ii) the increase of the moisture content in both oil and pressboard, under either positive or negative DC voltage, leads to the decrease of both the electric field strength in transformer oil and the charge density with time; and (iii) the increase of moisture content could not only decrease the resistivity of both oil and pressboard, but also the ratio of the resistivity between the pressboard and the oil. On the basis of the Maxwell–Wagner theory, the decrease of the ratio between the pressboard and oil could lead to the decrease of the interfacial charge density, leading to the slow transient process of the electric field in transformer oil under DC voltage. … (more)
- Is Part Of:
- High voltage. Volume 3:Issue 1(2018)
- Journal:
- High voltage
- Issue:
- Volume 3:Issue 1(2018)
- Issue Display:
- Volume 3, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 3
- Issue:
- 1
- Issue Sort Value:
- 2018-0003-0001-0000
- Page Start:
- 73
- Page End:
- 77
- Publication Date:
- 2018-02-07
- Subjects:
- transformer oil -- surface charging -- power transformer insulation -- composite insulating materials
interface charge -- oil‐pressboard composite insulation -- DC voltage -- moisture content -- surface charge accumulation -- Kerr electro‐optic effect -- electric field strengths -- transformer oil -- surface charge density -- oil resistivity -- pressboard resistivity -- negative charges -- Maxwell‐Wagner theory -- interfacial charge density
High voltages -- Periodicals
621.3191 - Journal URLs:
- http://ieeexplore.ieee.org/Xplore/home.jsp ↗
https://ietresearch.onlinelibrary.wiley.com/journal/23977264 ↗
http://digital-library.theiet.org/content/journals/hve ↗ - DOI:
- 10.1049/hve.2017.0096 ↗
- Languages:
- English
- ISSNs:
- 2397-7264
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4307.369710
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16468.xml