Development of a multi-channel magnetic bead micro-probe assay for high-throughput detection of zearalenone in edible and medicinal Coix seed. (15th June 2021)
- Record Type:
- Journal Article
- Title:
- Development of a multi-channel magnetic bead micro-probe assay for high-throughput detection of zearalenone in edible and medicinal Coix seed. (15th June 2021)
- Main Title:
- Development of a multi-channel magnetic bead micro-probe assay for high-throughput detection of zearalenone in edible and medicinal Coix seed
- Authors:
- Liu, Xiaofei
Liao, Xiaofang
Jia, Boyu
Sun, Chaonan
Zhou, Lidong
Kong, Weijun - Abstract:
- Highlights: An highly-sensitive multi-channel magnetic bead micro-probes assay (MBPA) was developed for hazardous ZEA. The MBPA strategy allowed extremely-low LOD of 2.03 ng/mL for ZEA in Coix seed. Broad dynamic range of 2.03–440.67 ng/mL was achieved for real application. 30 s of sample preparation and 50 μL of sample solution were needed for one run. High-throughput and fast assay was confirmed in 36 samples within 20 min. Abstract: A multi-channel magnetic bead micro-probes assay (MBPA) based on indirect competitive principle was developed for high-throughput detection of zearalenone (ZEA) in edible and medicinal Coix seed. This strategy introduced magnetic beads as the carriers, the specific primary antibodies as the capture probes for targets and the secondary antibodies functionalized goat anti-mouse immunoglobulin G labeled fluorescein isothiocyanate as the fluorescence signal probes. Through the competitive reaction of ZEA in Coix seed samples and that covalently coupled on the surface of MBs with their specific antibodies, as well as fast magnetic separation and sensitive fluorescence detection, the developed MBPA strategy allowed low limit of detection (2.03 ng/mL) with broad dynamic range (2.03–440.67 ng/mL), as well as excellent accuracy with the average recovery rate of 96.39% and relative standard deviation (RSD) of 5.48% for ZEA. 36 samples could realize simultaneous analysis in one operation within less than 20 min only needing 50 μL of solution and 30 s ofHighlights: An highly-sensitive multi-channel magnetic bead micro-probes assay (MBPA) was developed for hazardous ZEA. The MBPA strategy allowed extremely-low LOD of 2.03 ng/mL for ZEA in Coix seed. Broad dynamic range of 2.03–440.67 ng/mL was achieved for real application. 30 s of sample preparation and 50 μL of sample solution were needed for one run. High-throughput and fast assay was confirmed in 36 samples within 20 min. Abstract: A multi-channel magnetic bead micro-probes assay (MBPA) based on indirect competitive principle was developed for high-throughput detection of zearalenone (ZEA) in edible and medicinal Coix seed. This strategy introduced magnetic beads as the carriers, the specific primary antibodies as the capture probes for targets and the secondary antibodies functionalized goat anti-mouse immunoglobulin G labeled fluorescein isothiocyanate as the fluorescence signal probes. Through the competitive reaction of ZEA in Coix seed samples and that covalently coupled on the surface of MBs with their specific antibodies, as well as fast magnetic separation and sensitive fluorescence detection, the developed MBPA strategy allowed low limit of detection (2.03 ng/mL) with broad dynamic range (2.03–440.67 ng/mL), as well as excellent accuracy with the average recovery rate of 96.39% and relative standard deviation (RSD) of 5.48% for ZEA. 36 samples could realize simultaneous analysis in one operation within less than 20 min only needing 50 μL of solution and 30 s of sampling, avoiding large consumption of time and organic solvents. Multiple centrifugation and cleanup steps were omitted because of magnetic separation, avoiding the loss of targets. Diverse capture and fluorescent probes can be randomly bound onto the surface of MBs, making the MBPA strategy a promising tool for on-site high-throughput monitoring of various trace hazard factors in food safety, and environmental monitoring. … (more)
- Is Part Of:
- Food chemistry. Volume 347(2021)
- Journal:
- Food chemistry
- Issue:
- Volume 347(2021)
- Issue Display:
- Volume 347, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 347
- Issue:
- 2021
- Issue Sort Value:
- 2021-0347-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06-15
- Subjects:
- Coix seed -- Zearalenone -- Magnetic bead micro-probes assay -- Multi-channel high-throughput analysis -- Highly-sensitive detection
Food -- Analysis -- Periodicals
Food -- Composition -- Periodicals
664 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03088146 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.foodchem.2020.128977 ↗
- Languages:
- English
- ISSNs:
- 0308-8146
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3977.284000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15596.xml