Imprecision nutrition? Different simultaneous continuous glucose monitors provide discordant meal rankings for incremental postprandial glucose in subjects without diabetes. Issue 4 (7th August 2020)
- Record Type:
- Journal Article
- Title:
- Imprecision nutrition? Different simultaneous continuous glucose monitors provide discordant meal rankings for incremental postprandial glucose in subjects without diabetes. Issue 4 (7th August 2020)
- Main Title:
- Imprecision nutrition? Different simultaneous continuous glucose monitors provide discordant meal rankings for incremental postprandial glucose in subjects without diabetes
- Authors:
- Howard, Rebecca
Guo, Juen
Hall, Kevin D - Abstract:
- ABSTRACT: Background: High postprandial glucose excursions may increase risk for disease. Individuals have widely varying glucose responses to different meals, and precision nutrition approaches often seek to personalize diets to minimize postprandial glycemic responses as measured by continuous glucose monitors (CGMs). However, it is unknown whether different CGM devices result in concordant meal rankings according to postprandial glycemic excursions. Objective: We explored whether meal rankings according to postprandial glycemic excursions differ between 2 simultaneously worn CGMs. Methods: We collected 27, 489 simultaneous measurements from Dexcom G4 Platinum and Abbott Freestyle Libre Pro CGMs during 28 inpatient days in 16 adults without diabetes. Simultaneous glucose measurements obtained for 2 h following 760 ad libitum meals were used to compare within-subject meal rankings between the CGM devices according to their incremental glucose response. Results: Postprandial responses to ad libitum meals were highly variable, with the Abbott and Dexcom systems resulting in within-subject incremental mean ± SD glucose CVs of 91.7 ± 1.9% and 94.2 ± 2.7%, respectively. Within-subject meal rankings for incremental glycemic responses were relatively discordant between CGMs, with a mean Kendall rank correlation coefficient of 0.43 ± 0.05. Meals in the bottom compared with those in the top half of incremental glycemic responses ranked by Abbott resulted in 50 ± 10% ( P = 0.0002)ABSTRACT: Background: High postprandial glucose excursions may increase risk for disease. Individuals have widely varying glucose responses to different meals, and precision nutrition approaches often seek to personalize diets to minimize postprandial glycemic responses as measured by continuous glucose monitors (CGMs). However, it is unknown whether different CGM devices result in concordant meal rankings according to postprandial glycemic excursions. Objective: We explored whether meal rankings according to postprandial glycemic excursions differ between 2 simultaneously worn CGMs. Methods: We collected 27, 489 simultaneous measurements from Dexcom G4 Platinum and Abbott Freestyle Libre Pro CGMs during 28 inpatient days in 16 adults without diabetes. Simultaneous glucose measurements obtained for 2 h following 760 ad libitum meals were used to compare within-subject meal rankings between the CGM devices according to their incremental glucose response. Results: Postprandial responses to ad libitum meals were highly variable, with the Abbott and Dexcom systems resulting in within-subject incremental mean ± SD glucose CVs of 91.7 ± 1.9% and 94.2 ± 2.7%, respectively. Within-subject meal rankings for incremental glycemic responses were relatively discordant between CGMs, with a mean Kendall rank correlation coefficient of 0.43 ± 0.05. Meals in the bottom compared with those in the top half of incremental glycemic responses ranked by Abbott resulted in 50 ± 10% ( P = 0.0002) less glycemic reduction as measured by Dexcom, and vice versa. The missing glycemic reduction by eating meals ranked according to the discordant CGM was inversely correlated with each subject's Kendall rank correlation coefficient ( r = −0.95; P < 0.0001). Conclusions: Precision nutrition approaches that use CGMs to personalize meal recommendations for minimizing glycemic excursions may be premature given the discordance of within-subject meal rankings between simultaneous CGM devices. More research is needed to clarify the source of this imprecision. This trial was registered at clinicaltrials.gov as NCT03407053. … (more)
- Is Part Of:
- American journal of clinical nutrition. Volume 112:Issue 4(2020)
- Journal:
- American journal of clinical nutrition
- Issue:
- Volume 112:Issue 4(2020)
- Issue Display:
- Volume 112, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 112
- Issue:
- 4
- Issue Sort Value:
- 2020-0112-0004-0000
- Page Start:
- 1114
- Page End:
- 1119
- Publication Date:
- 2020-08-07
- Subjects:
- continuous glucose monitor -- glycemia -- glucose variability -- personalized nutrition -- precision nutrition
Diet therapy -- Periodicals
Nutrition -- Periodicals
Dietetics -- Periodicals
613.205 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/ajcn/ ↗
https://www.sciencedirect.com/journal/the-american-journal-of-clinical-nutrition ↗
https://ajcn.nutrition.org/ ↗ - DOI:
- 10.1093/ajcn/nqaa198 ↗
- Languages:
- English
- ISSNs:
- 0002-9165
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0823.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14861.xml