LO10: Low high-sensitivity troponin concentrations identify low-risk chest pain patients unlikely to benefit from further risk stratification. (May 2020)
- Record Type:
- Journal Article
- Title:
- LO10: Low high-sensitivity troponin concentrations identify low-risk chest pain patients unlikely to benefit from further risk stratification. (May 2020)
- Main Title:
- LO10: Low high-sensitivity troponin concentrations identify low-risk chest pain patients unlikely to benefit from further risk stratification
- Authors:
- Andruchow, J.
Boyne, T.
Innes, G.
Vatanpour, S.
Seiden-Long, I.
Wang, D.
Lang, E.
McRae, A. - Abstract:
- Abstract : Introduction: Very low high-sensitivity troponin-T (hs-cTnT) concentrations on presentation can rule out acute myocardial infarction (AMI), but the ability to identify patients at low risk of 30-day major adverse cardiac events (MACE) is less clear. This study examines the sensitivity of low concentrations of hs-cTnT on presentation to rule out 30-day MACE. Methods: This prospective cohort study enrolled emergency department chest pain patients with non-ischemic ECGs who underwent AMI rule-out with an hs-cTnT assay. The primary outcome was 30-day MACE; secondary outcomes were individual MACE components. Because guidelines recommend using a single hs-cTnT strategy only for patients with more than 3-hours since symptom onset, a subgroup analysis was performed for this population. Outcomes were adjudicated based on review of medical records and telephone follow-up. Results: Of 1, 167 patients enrolled, 125 (10.7%) experienced 30-day MACE and 97 (8.3%) suffered AMI on the index visit. More than one-third (35.6%) had presenting hs-cTnT concentrations below the limit of detection (5ng/L), which was 94.4% (95%CI 88.8-97.7%) sensitive for 30-day MACE and 99.0% (95%CI 94.5-100%) sensitive for index AMI. Of 292 (25.0%) patients with hs-cTnT < 5ng/L and at least 3-hours since symptom onset, only 3 experienced 30-day MACE (sensitivity 97.6%, 95%CI 93.2-100%) and none suffered AMI within 30-days (sensitivity 100%, 95%CI 96.3-100%). Conclusion: Among patients with non-ischemicAbstract : Introduction: Very low high-sensitivity troponin-T (hs-cTnT) concentrations on presentation can rule out acute myocardial infarction (AMI), but the ability to identify patients at low risk of 30-day major adverse cardiac events (MACE) is less clear. This study examines the sensitivity of low concentrations of hs-cTnT on presentation to rule out 30-day MACE. Methods: This prospective cohort study enrolled emergency department chest pain patients with non-ischemic ECGs who underwent AMI rule-out with an hs-cTnT assay. The primary outcome was 30-day MACE; secondary outcomes were individual MACE components. Because guidelines recommend using a single hs-cTnT strategy only for patients with more than 3-hours since symptom onset, a subgroup analysis was performed for this population. Outcomes were adjudicated based on review of medical records and telephone follow-up. Results: Of 1, 167 patients enrolled, 125 (10.7%) experienced 30-day MACE and 97 (8.3%) suffered AMI on the index visit. More than one-third (35.6%) had presenting hs-cTnT concentrations below the limit of detection (5ng/L), which was 94.4% (95%CI 88.8-97.7%) sensitive for 30-day MACE and 99.0% (95%CI 94.5-100%) sensitive for index AMI. Of 292 (25.0%) patients with hs-cTnT < 5ng/L and at least 3-hours since symptom onset, only 3 experienced 30-day MACE (sensitivity 97.6%, 95%CI 93.2-100%) and none suffered AMI within 30-days (sensitivity 100%, 95%CI 96.3-100%). Conclusion: Among patients with non-ischemic ECGs and >3-hours since symptom onset, low hs-cTnT concentrations on presentation confer a very low risk of 30-day MACE. In the absence of a high risk clinical presentation, further risk stratification is likely to be low yield. … (more)
- Is Part Of:
- CJEM. Volume 22(2020)Supplement 1
- Journal:
- CJEM
- Issue:
- Volume 22(2020)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2020-0022-0001-0000
- Page Start:
- S10
- Page End:
- S10
- Publication Date:
- 2020-05
- Subjects:
- high-sensitivity troponin, -- myocardial infarction, -- risk stratification
Emergency Treatment -- Periodicals
Emergency Medicine -- Periodicals
Emergency medical services -- Canada -- Periodicals
Medical emergencies -- Canada -- Periodicals
Emergency medical services
Medical emergencies
Canada
Periodicals
616.02505 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=CEM ↗
http://www.caep.ca/004.cjem-jcmu/004-00.cjem/004-01v.archives.htm#main ↗
http://link.springer.com/ ↗ - DOI:
- 10.1017/cem.2020.66 ↗
- Languages:
- English
- ISSNs:
- 1481-8035
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14681.xml