LO23: Do point of care ultrasound findings of left ventricular dysfunction predict cardiogenic shock in undifferentiated hypotensive patients?. (May 2020)
- Record Type:
- Journal Article
- Title:
- LO23: Do point of care ultrasound findings of left ventricular dysfunction predict cardiogenic shock in undifferentiated hypotensive patients?. (May 2020)
- Main Title:
- LO23: Do point of care ultrasound findings of left ventricular dysfunction predict cardiogenic shock in undifferentiated hypotensive patients?
- Authors:
- Atkinson, P.
Fraser, J.
Lewis, D.
Pham, C.
Lamprecht, H.
Stander, M.
French, J.
Sibley, A.
Henneberry, R. - Abstract:
- Abstract : Introduction: Patients presenting to the emergency department (ED) with hypotension have a high mortality rate and require careful yet rapid resuscitation. The use of cardiac point of care ultrasound (PoCUS) in the ED has progressed beyond the basic indications of detecting pericardial fluid and activity in cardiac arrest. We examine if finding left ventricular dysfunction (LVD) on emergency physician performed PoCUS reliably predicts the presence of cardiogenic shock in hypotensive ED patients. Methods: We prospectively collected PoCUS findings performed in 135 ED patients with undifferentiated hypotension as part of an international study. Patients with clearly identified etiologies for hypotension were excluded, along with other specific presumptive diagnoses. LVD was defined as identification of a generally hypodynamic LV in the setting of shock. PoCUS findings were collected using a standardized protocol and data collection form. All scans were performed by PoCUS-trained emergency physicians. Final shock type was defined as cardiogenic or non-cardiogenic by independent specialist blinded chart review. Results: All 135 patients had complete follow up. Median age was 56 years, 53% of patients were male. Disease prevalence for cardiogenic shock was 12% and the mortality rate was 24%. The presence of LVD on PoCUS had a sensitivity of 62.50% (95%CI 35.43% to 84.80%), specificity of 94.12% (88.26% to 97.60%), positive-LR 10.62 (4.71 to 23.95), negative-LR 0.40Abstract : Introduction: Patients presenting to the emergency department (ED) with hypotension have a high mortality rate and require careful yet rapid resuscitation. The use of cardiac point of care ultrasound (PoCUS) in the ED has progressed beyond the basic indications of detecting pericardial fluid and activity in cardiac arrest. We examine if finding left ventricular dysfunction (LVD) on emergency physician performed PoCUS reliably predicts the presence of cardiogenic shock in hypotensive ED patients. Methods: We prospectively collected PoCUS findings performed in 135 ED patients with undifferentiated hypotension as part of an international study. Patients with clearly identified etiologies for hypotension were excluded, along with other specific presumptive diagnoses. LVD was defined as identification of a generally hypodynamic LV in the setting of shock. PoCUS findings were collected using a standardized protocol and data collection form. All scans were performed by PoCUS-trained emergency physicians. Final shock type was defined as cardiogenic or non-cardiogenic by independent specialist blinded chart review. Results: All 135 patients had complete follow up. Median age was 56 years, 53% of patients were male. Disease prevalence for cardiogenic shock was 12% and the mortality rate was 24%. The presence of LVD on PoCUS had a sensitivity of 62.50% (95%CI 35.43% to 84.80%), specificity of 94.12% (88.26% to 97.60%), positive-LR 10.62 (4.71 to 23.95), negative-LR 0.40 (0.21 to 0.75) and accuracy of 90.37% (84.10% to 94.77%) for detecting cardiogenic shock. Conclusion: Detecting left ventricular dysfunction on PoCUS in the ED may be useful in confirming the underlying shock type as cardiogenic in otherwise undifferentiated hypotensive patients. … (more)
- Is Part Of:
- CJEM. Volume 22(2020)Supplement 1
- Journal:
- CJEM
- Issue:
- Volume 22(2020)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2020-0022-0001-0000
- Page Start:
- S15
- Page End:
- S15
- Publication Date:
- 2020-05
- Subjects:
- echocardiography, -- hypotension, -- point of care ultrasound
Emergency Treatment -- Periodicals
Emergency Medicine -- Periodicals
Emergency medical services -- Canada -- Periodicals
Medical emergencies -- Canada -- Periodicals
Emergency medical services
Medical emergencies
Canada
Periodicals
616.02505 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=CEM ↗
http://www.caep.ca/004.cjem-jcmu/004-00.cjem/004-01v.archives.htm#main ↗
http://link.springer.com/ ↗ - DOI:
- 10.1017/cem.2020.79 ↗
- Languages:
- English
- ISSNs:
- 1481-8035
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14680.xml