LO01: Development and validation of an adjustment score for ruling out MI using a single high-sensitivity cardiac troponin T assay in patients with chest pain and kidney dysfunction. (May 2019)
- Record Type:
- Journal Article
- Title:
- LO01: Development and validation of an adjustment score for ruling out MI using a single high-sensitivity cardiac troponin T assay in patients with chest pain and kidney dysfunction. (May 2019)
- Main Title:
- LO01: Development and validation of an adjustment score for ruling out MI using a single high-sensitivity cardiac troponin T assay in patients with chest pain and kidney dysfunction
- Authors:
- McRae, A.
Vatanpour, S.
Ma, J.
Lang, E.
Andruchow, J.
Innes, G.
James, M.
Worster, A.
Kavsak, P. - Abstract:
- Abstract : Introduction : Very low concentrations of high-sensitivity cardiac troponin can rule-out myocardial infarction (MI) at ED arrival in patients with chest pain. However, this single troponin rule-out strategy works poorly in patients with renal impairment and elevated baseline troponin levels. The objective of this study was to develop and validate a troponin adjustment strategy to accurately rule-out MI with a single hs-cTnTmeasurement in patients with kidney dysfunction.Methods : We used data from three cohorts of ED chest pain patients to develop an adjustment score for a high-sensitivity troponin T (hs-cTnT) assay in patients with kidney dysfunction. The derivation cohort (n = 8846) used administrative and registry data. Two validation cohorts (n = 1187 and 1092) were prospectively-collected. The score assigned points for increasing hs-cTnT levels and subtracted points for lower estimated glomerular filtration rate (eGFR). In the derivation cohort, hs-cTnT concentrations achieving 98.5% sensitivity in of patients with eGFR ≥60, 45-59, 30-44, 15-29 and <15 were assigned ascending positive integer values. Negative integer values were assigned to eGFR values 45-59, 30-44, 15-29 and <15. The scpres for troponin and eGFR were summed for each patient, with scores ranging from −4 to +5. The proportion of patients with 7-day MI ruled out by a score ≤0, sensitivity, NPV, negative likelihood ratio (LR-) and area under the curve (AUC) were quantified in each studyAbstract : Introduction : Very low concentrations of high-sensitivity cardiac troponin can rule-out myocardial infarction (MI) at ED arrival in patients with chest pain. However, this single troponin rule-out strategy works poorly in patients with renal impairment and elevated baseline troponin levels. The objective of this study was to develop and validate a troponin adjustment strategy to accurately rule-out MI with a single hs-cTnTmeasurement in patients with kidney dysfunction.Methods : We used data from three cohorts of ED chest pain patients to develop an adjustment score for a high-sensitivity troponin T (hs-cTnT) assay in patients with kidney dysfunction. The derivation cohort (n = 8846) used administrative and registry data. Two validation cohorts (n = 1187 and 1092) were prospectively-collected. The score assigned points for increasing hs-cTnT levels and subtracted points for lower estimated glomerular filtration rate (eGFR). In the derivation cohort, hs-cTnT concentrations achieving 98.5% sensitivity in of patients with eGFR ≥60, 45-59, 30-44, 15-29 and <15 were assigned ascending positive integer values. Negative integer values were assigned to eGFR values 45-59, 30-44, 15-29 and <15. The scpres for troponin and eGFR were summed for each patient, with scores ranging from −4 to +5. The proportion of patients with 7-day MI ruled out by a score ≤0, sensitivity, NPV, negative likelihood ratio (LR-) and area under the curve (AUC) were quantified in each study cohort.Results : The derivation and validation cohorts had 7-day MI rates of 5.7, 8.6 and 9.1%. In the derivation cohort, a score ≤0 ruled out MI in 35% of patients, with a sensitivity for 7-day MI of 99.5% (95% CI 98-100), NPV of 99.9% (95% CI 98.4-99.9), LR- of 0.02 (95% CI 0.01-0.05) and AUC of 0.88. In the first validation cohort, a score ≤0 ruled out MI in 45% of patients, with a sensitivity for 7-day MI of 97% (95% CI 90-100%), NPV of 99% (95% CI 98-100%), LR- 0.06 (0.02-0.18) and AUC of 0.89. In the second validation cohort, a score ≤0 ruled out MI in 20% of patients, with a sensitivity for 7-day MI of 96% (95% CI 93-99%), NPV of 98% (95% CI 96-100%), LR- of 0.16 (95% CI 0.07-0.39) and AUC of 0.78.Conclusion : We developed and validated a simple scoring system to adjust hs-cTnT concentrations for a patient's kidney function that enables MI to be ruled out in a large proportion of chest pain patients using a single measurement on ED presentation. … (more)
- Is Part Of:
- CJEM. Volume 21(2019)Supplement 1
- Journal:
- CJEM
- Issue:
- Volume 21(2019)Supplement 1
- Issue Display:
- Volume 21, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 21
- Issue:
- 1
- Issue Sort Value:
- 2019-0021-0001-0000
- Page Start:
- S6
- Page End:
- S7
- Publication Date:
- 2019-05
- Subjects:
- kidney disease, -- myocardial infarction, -- troponin
Emergency Treatment -- Periodicals
Emergency Medicine -- Periodicals
Emergency medical services -- Canada -- Periodicals
Medical emergencies -- Canada -- Periodicals
Emergency medical services
Medical emergencies
Canada
Periodicals
616.02505 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=CEM ↗
http://www.caep.ca/004.cjem-jcmu/004-00.cjem/004-01v.archives.htm#main ↗
http://link.springer.com/ ↗ - DOI:
- 10.1017/cem.2019.44 ↗
- Languages:
- English
- ISSNs:
- 1481-8035
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11057.xml