Effects of Two Different Self-Adapted Occlusal Splints on Electromyographic and Force Parameters During Elbow Flexors Isometric Contraction. Issue 1 (January 2018)
- Record Type:
- Journal Article
- Title:
- Effects of Two Different Self-Adapted Occlusal Splints on Electromyographic and Force Parameters During Elbow Flexors Isometric Contraction. Issue 1 (January 2018)
- Main Title:
- Effects of Two Different Self-Adapted Occlusal Splints on Electromyographic and Force Parameters During Elbow Flexors Isometric Contraction
- Authors:
- Limonta, Eloisa
Arienti, Chiara
Rampichini, Susanna
Venturelli, Massimo
Cè, Emiliano
Veicsteinas, Arsenio
Esposito, Fabio - Abstract:
- Abstract : Abstract: Limonta, E, Arienti, C, Rampichini, S, Venturelli, M, Cè, E, Veicsteinas, A, and Esposito, F. Effects of two different self-adapted occlusal splints on electromyographic and force parameters during elbow flexors isometric contraction. J Strength Cond Res 32(1): 230–236, 2018—The study was aimed at determining the acute effects of 2 types of occlusal splints on maximum isometric strength and fatigue of the elbow flexors muscles. The hypothesis was that splint-induced masticatory muscle repositioning might improve primary muscles recruitment by stretching masticatory muscles especially with the thicker splint. On 9 physically active volunteers with no temporomandibular joint and masticatory muscles disorders, we assessed maximum voluntary contraction (MVC) of the elbow flexors with diurnal (OSD, 1-mm thick) and sport (OSSP, 3-mm thick) splints, and without splint (control, Ctrl). On different days, participants performed 60 seconds of isometric contraction at 100% MVC (100%60s ) and 80% MVC contraction until exhaustion (80%exh ) under OSD, OSSP, and Ctrl in random order. Time of force output within target (t-target), force distance from target (Δ F ), and force coefficient of variation were calculated. Percentage of force decay (ΔFi-Fe ) was determined during 100%60s . From the electromyographic (EMG) signal, root mean square (EMG RMS) and mean frequency (EMG MF) were determined. Neuromuscular efficiency (NE) was calculated as the ratio between force andAbstract : Abstract: Limonta, E, Arienti, C, Rampichini, S, Venturelli, M, Cè, E, Veicsteinas, A, and Esposito, F. Effects of two different self-adapted occlusal splints on electromyographic and force parameters during elbow flexors isometric contraction. J Strength Cond Res 32(1): 230–236, 2018—The study was aimed at determining the acute effects of 2 types of occlusal splints on maximum isometric strength and fatigue of the elbow flexors muscles. The hypothesis was that splint-induced masticatory muscle repositioning might improve primary muscles recruitment by stretching masticatory muscles especially with the thicker splint. On 9 physically active volunteers with no temporomandibular joint and masticatory muscles disorders, we assessed maximum voluntary contraction (MVC) of the elbow flexors with diurnal (OSD, 1-mm thick) and sport (OSSP, 3-mm thick) splints, and without splint (control, Ctrl). On different days, participants performed 60 seconds of isometric contraction at 100% MVC (100%60s ) and 80% MVC contraction until exhaustion (80%exh ) under OSD, OSSP, and Ctrl in random order. Time of force output within target (t-target), force distance from target (Δ F ), and force coefficient of variation were calculated. Percentage of force decay (ΔFi-Fe ) was determined during 100%60s . From the electromyographic (EMG) signal, root mean square (EMG RMS) and mean frequency (EMG MF) were determined. Neuromuscular efficiency (NE) was calculated as the ratio between force and EMG RMS. MVC contraction and NE were significantly higher in OSSP and OSD than in Ctrl. During MVC, EMG MF was significantly lower in both splint conditions, and EMG RMS showed a nonstatistical tendency to lower values under both splint conditions. During 80%exh, t-target was longer in OSD and OSSP (+7.8% and +5.2%, respectively) than in Ctrl. ΔFi-Fe was lower in OSSP than in Ctrl and OSD . These results support the hypothesis of a NE improvement of the elbow flexors possibly induced by acute, splint-induced masticatory muscles repositioning. … (more)
- Is Part Of:
- Journal of strength and conditioning research. Volume 32:Issue 1(2018)
- Journal:
- Journal of strength and conditioning research
- Issue:
- Volume 32:Issue 1(2018)
- Issue Display:
- Volume 32, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 32
- Issue:
- 1
- Issue Sort Value:
- 2018-0032-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-01
- Subjects:
- strength -- endurance -- mouthguard -- fatigue -- EMG
Physical education and training -- Periodicals
Weight training -- Physiological aspects -- Periodicals
Physical fitness -- Periodicals
613.7 - Journal URLs:
- http://journals.lww.com/nsca-jscr/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1519/JSC.0000000000002178 ↗
- Languages:
- English
- ISSNs:
- 1064-8011
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5066.873700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8803.xml