Low-power MicroVrms noise neural spike detector for implantable interface microsystem device. Issue 5 (April 2015)
- Record Type:
- Journal Article
- Title:
- Low-power MicroVrms noise neural spike detector for implantable interface microsystem device. Issue 5 (April 2015)
- Main Title:
- Low-power MicroVrms noise neural spike detector for implantable interface microsystem device
- Authors:
- Li, Hongge
Bai, Huixin
Xu, Qicheng
Xia, Tongsheng - Abstract:
- Highlights: An ultra-low-power and low-noise detector based on NEO is implemented using standard CMOS process. The NEO detector circuit CMOS-based is realised using sub-threshold technique. We study the noise of NEO circuit and obtain the MicroVrms noise result. We test the chip of NEO detector about the current consumption, noise, and detecting function. Abstract: In this paper, an ultra-low-power and low-noise spike detector is proposed for massive integration in the implantable multichannel brain neural recording device. The detector circuit with nonlinear energy operator (NEO) algorithms achieves the spike detecting from action potential including complex noise. The spike detector circuit consists of a differentiator with a fully-differential structure and a multiplier based on CMOS translinear using sub-threshold technique. The differentiator has the steepness of a transmission function with frequency +20 dB/dec, frequency response from 10 Hz to 10.5 kHz. The linear range of multiplier is from −0.9 V to 0.9 V at V DD = ±1.65 V. The spike detector is implemented in 0.35 μm technology with fully-CMOS process. One detector die size is 0.0187 mm 2 and its total current consumption of 825 nA. As is demonstrated by measured results, the proposed circuit has detected the instantaneous energy of the input real spike signals well, which the noise of small than 218 μVrms over a nominal bandwidth of 500–10.5 kHz.
- Is Part Of:
- Microelectronics and reliability. Volume 55:Issue 5(2015)
- Journal:
- Microelectronics and reliability
- Issue:
- Volume 55:Issue 5(2015)
- Issue Display:
- Volume 55, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 55
- Issue:
- 5
- Issue Sort Value:
- 2015-0055-0005-0000
- Page Start:
- 807
- Page End:
- 814
- Publication Date:
- 2015-04
- Subjects:
- Biopotential detector -- NEO algorithms -- Ultra-low-power -- Sub-threshold -- Low noise
Electronic apparatus and appliances -- Reliability -- Periodicals
Miniature electronic equipment -- Periodicals
Appareils électroniques -- Fiabilité -- Périodiques
Équipement électronique miniaturisé -- Périodiques
Electronic apparatus and appliances -- Reliability
Miniature electronic equipment
Periodicals
621.3815 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00262714 ↗
http://www.elsevier.com/journals ↗
http://www.elsevier.com/homepage/elecserv.htt ↗ - DOI:
- 10.1016/j.microrel.2015.02.001 ↗
- Languages:
- English
- ISSNs:
- 0026-2714
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5758.979000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6394.xml