Mechanical and electrical characterisation of Au wire interconnects in electronic packages under the combined vibration and thermal testing conditions. Issue 6 (May 2015)
- Record Type:
- Journal Article
- Title:
- Mechanical and electrical characterisation of Au wire interconnects in electronic packages under the combined vibration and thermal testing conditions. Issue 6 (May 2015)
- Main Title:
- Mechanical and electrical characterisation of Au wire interconnects in electronic packages under the combined vibration and thermal testing conditions
- Authors:
- Mirgkizoudi, M.
Liu, C.
Conway, P.P.
Riches, S. - Abstract:
- Highlights: The ball shear strength levels drop drastically after the combined testing. The wire pull strength levels remain high. The electrical resistance initially decreases then increases after further testing. Wires vertical to the direction of vibration undergo larger deformation. Abstract: This paper concerns the reliability of thermosonically bonded 25 μm Au wires in the combined high temperature with vibration conditions, under which the tests have been carried out on wire-bonded 48-pin Dual-in-Line (DIL) High Temperature Co-fired Ceramic (HTCC) electronic packages. Mechanical, optical and electrical analysis has been undertaken in order to identify the failure mechanisms of bonded wires due to the combined testing. The results indicated a decrease in the electrical resistance after a few hours of testing as a result of the annealing process of the Au wire during testing. In general, ball shear and wire pull strength levels remained high after testing, showing no significant deterioration due to the tests under the combined high temperature and vibration conditions. However, a trend of the variation in the strength values is identified with respect to the combined conditions for all wire-bonded packages, which may be summarised as: (i) increase of the testing temperature has led to a decrease of both the shear and pull strength of the wire bonds; (ii) the mechanical behaviour of the wires is affected due to crystallisation that leads to material softening andHighlights: The ball shear strength levels drop drastically after the combined testing. The wire pull strength levels remain high. The electrical resistance initially decreases then increases after further testing. Wires vertical to the direction of vibration undergo larger deformation. Abstract: This paper concerns the reliability of thermosonically bonded 25 μm Au wires in the combined high temperature with vibration conditions, under which the tests have been carried out on wire-bonded 48-pin Dual-in-Line (DIL) High Temperature Co-fired Ceramic (HTCC) electronic packages. Mechanical, optical and electrical analysis has been undertaken in order to identify the failure mechanisms of bonded wires due to the combined testing. The results indicated a decrease in the electrical resistance after a few hours of testing as a result of the annealing process of the Au wire during testing. In general, ball shear and wire pull strength levels remained high after testing, showing no significant deterioration due to the tests under the combined high temperature and vibration conditions. However, a trend of the variation in the strength values is identified with respect to the combined conditions for all wire-bonded packages, which may be summarised as: (i) increase of the testing temperature has led to a decrease of both the shear and pull strength of the wire bonds; (ii) the mechanical behaviour of the wires is affected due to crystallisation that leads to material softening and consequently the deformation of wire. … (more)
- Is Part Of:
- Microelectronics and reliability. Volume 55:Issue 6(2015)
- Journal:
- Microelectronics and reliability
- Issue:
- Volume 55:Issue 6(2015)
- Issue Display:
- Volume 55, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 55
- Issue:
- 6
- Issue Sort Value:
- 2015-0055-0006-0000
- Page Start:
- 952
- Page End:
- 960
- Publication Date:
- 2015-05
- Subjects:
- Wire bonding -- Reliability testing -- High temperature -- Vibration
Electronic apparatus and appliances -- Reliability -- Periodicals
Miniature electronic equipment -- Periodicals
Appareils électroniques -- Fiabilité -- Périodiques
Équipement électronique miniaturisé -- Périodiques
Electronic apparatus and appliances -- Reliability
Miniature electronic equipment
Periodicals
621.3815 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00262714 ↗
http://www.elsevier.com/journals ↗
http://www.elsevier.com/homepage/elecserv.htt ↗ - DOI:
- 10.1016/j.microrel.2015.02.023 ↗
- Languages:
- English
- ISSNs:
- 0026-2714
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5758.979000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6372.xml