Development and validation of an LC–MS/MS/MS method for the quantification of fluoroquinolones in several matrices from treated turkeys. (February 2015)
- Record Type:
- Journal Article
- Title:
- Development and validation of an LC–MS/MS/MS method for the quantification of fluoroquinolones in several matrices from treated turkeys. (February 2015)
- Main Title:
- Development and validation of an LC–MS/MS/MS method for the quantification of fluoroquinolones in several matrices from treated turkeys
- Authors:
- Lucatello, Lorena
Cagnardi, Petra
Capolongo, Francesca
Ferraresi, Caterina
Bernardi, Filippo
Montesissa, Clara - Abstract:
- Abstract: The study presents a sensitive and reliable confirmatory method for the extraction, identification, quantification of five fluoroquinolones (FQ) namely enrofloxacin, ciprofloxacin, difloxacin, sarafloxacin and flumequine, in plasma, liver, kidney, muscle, skin + fat, lung and intestinal content from turkeys. For the extraction and matrix clean-up of FQ residues from all biological matrices, the Quick Easy Cheap Effective Rugged Safe (QuEChERS) methodology was adopted; only for plasma samples acetonitrile was used. The analyses were performed by liquid chromatography with mass spectrometry detection (LC–MS). LC separation was performed on a C18 Kinetex column (100 × 2.1 mm, 2.6 μm, Phenomenex, CA, USA) with gradient elution using ammonium acetate solution (10 mM, pH 2.5) and methanol containing 0.1% formic acid. Mass spectrometric identification was done using an LTQ XL ion trap (Thermo Fisher Scientific, CA, USA), with a heated electrospray ionization probe, in positive ion mode. The method was validated according to the European Legislation (decision 2002/657/EC) and EMA guideline (EMA/CVMP/VICH/463202/2009); selectivity, linearity response, trueness (in terms of recovery), precision (within-day repeatability and within-laboratory reproducibility), limit of detection, limit of quantification, decision limits, detection capability, absolute recovery and robustness were evaluated using turkey blank matrices. All data were within the required limits established forAbstract: The study presents a sensitive and reliable confirmatory method for the extraction, identification, quantification of five fluoroquinolones (FQ) namely enrofloxacin, ciprofloxacin, difloxacin, sarafloxacin and flumequine, in plasma, liver, kidney, muscle, skin + fat, lung and intestinal content from turkeys. For the extraction and matrix clean-up of FQ residues from all biological matrices, the Quick Easy Cheap Effective Rugged Safe (QuEChERS) methodology was adopted; only for plasma samples acetonitrile was used. The analyses were performed by liquid chromatography with mass spectrometry detection (LC–MS). LC separation was performed on a C18 Kinetex column (100 × 2.1 mm, 2.6 μm, Phenomenex, CA, USA) with gradient elution using ammonium acetate solution (10 mM, pH 2.5) and methanol containing 0.1% formic acid. Mass spectrometric identification was done using an LTQ XL ion trap (Thermo Fisher Scientific, CA, USA), with a heated electrospray ionization probe, in positive ion mode. The method was validated according to the European Legislation (decision 2002/657/EC) and EMA guideline (EMA/CVMP/VICH/463202/2009); selectivity, linearity response, trueness (in terms of recovery), precision (within-day repeatability and within-laboratory reproducibility), limit of detection, limit of quantification, decision limits, detection capability, absolute recovery and robustness were evaluated using turkey blank matrices. All data were within the required limits established for confirmatory methods except for flumequine which presented a recovery value slightly higher than 110% in muscle and intestinal content. For all FQs, all the extraction rates were greater than 70% and limits of quantification ranged from 1.2 μg kg −1 to 118.8 μg kg −1 . This fast and robust method was suitable for the identification and quantification of FQ residues in tissues, plasma and intestinal content as confirmed by data obtained from incurred samples of turkeys treated at farm for therapeutic purposes. Highlights: An LC–MS method was developed for five fluoroquinolones quantification. The method was validated in seven matrices (tissues and fluids) from turkeys. The fluoroquinolones were detectable in a wide range of concentrations. The method was successfully applied to plasma samples for pharmacokinetic study. Residue distribution and depletion were evaluated for two fluoroquinolones. … (more)
- Is Part Of:
- Food control. Volume 48(2015:Feb.)
- Journal:
- Food control
- Issue:
- Volume 48(2015:Feb.)
- Issue Display:
- Volume 48 (2015)
- Year:
- 2015
- Volume:
- 48
- Issue Sort Value:
- 2015-0048-0000-0000
- Page Start:
- 2
- Page End:
- 11
- Publication Date:
- 2015-02
- Subjects:
- Fluoroquinolone -- Residue depletion -- Pharmacokinetics -- Turkey -- QuEChERS -- LC–MS
FQ fluoroquinolone -- ENRO enrofloxacin -- CIPRO ciprofloxacin -- DIFLO difloxacin -- SARA sarafloxacin -- FLUME flumequine -- NOR norfloxacin -- IS internal standard -- MRL maximum residual limit
Food -- Quality -- Periodicals
Food -- Analysis -- Periodicals
Food handling -- Periodicals
Food industry and trade -- Quality control -- Periodicals
Aliments -- Industrie et commerce -- Qualité -- Contrôle -- Périodiques
Aliments -- Qualité -- Périodiques
Aliments -- Analyse -- Périodiques
Hygiène alimentaire -- Périodiques
Food -- Analysis
Food handling
Food -- Quality
Periodicals
Electronic journals
664.07 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09567135 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.foodcont.2014.04.011 ↗
- Languages:
- English
- ISSNs:
- 0956-7135
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3977.291500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5556.xml