Routine quantification of 54 allergens in fragrances using comprehensive two‐dimensional gas chromatography‐quadrupole mass spectrometry with dual parallel secondary columns. Part I: Method development. (29th October 2017)
- Record Type:
- Journal Article
- Title:
- Routine quantification of 54 allergens in fragrances using comprehensive two‐dimensional gas chromatography‐quadrupole mass spectrometry with dual parallel secondary columns. Part I: Method development. (29th October 2017)
- Main Title:
- Routine quantification of 54 allergens in fragrances using comprehensive two‐dimensional gas chromatography‐quadrupole mass spectrometry with dual parallel secondary columns. Part I: Method development
- Authors:
- Belhassen, Emilie
Bressanello, Davide
Merle, Philippe
Raynaud, Elsa
Bicchi, Carlo
Chaintreau, Alain
Cordero, Chiara - Abstract:
- Abstract: The forthcoming extension of the regulated fragrance allergen number is raising a challenge: the previously developed quantification methods need to be drastically improved in terms of rapidity, without altering their reliability. This work describes a procedure based on comprehensive bidimensional gas chromatography, hyphenated with a low‐cost quadrupole mass spectrometer (GCxGC‐QMS). The second chromatographic dimension was operated in a dual configuration, consisting of two parallel secondary columns, one being connected to the QMS, the other to a flame ionization detector (FID). This not only allowed optimization of the chromatographic gas flows when compared to the usual single second dimension, but it also enabled the use of the FID signal to extend the quantification range from 2 to 10, 000 mg/kg. The QMS was used at a low level (2‐100 mg/kg), where coelutions are frequent, and the FID was used for the most abundant analytes (100‐10, 000 mg/kg) with a low risk of significant interferences. To assess the identity and purity of the analyte peak at low level, we propose a strategy and summarize it in a decisional tree. To our knowledge, this represents the first fully developed quantification method based on a GCx2GC‐QMS/FID system. In contrast to other methods, it enables the quantification of a wide variety of analytes in fragrances in a single run, without requiring a series of sample dilutions to match the calibration range. Abstract : We describe aAbstract: The forthcoming extension of the regulated fragrance allergen number is raising a challenge: the previously developed quantification methods need to be drastically improved in terms of rapidity, without altering their reliability. This work describes a procedure based on comprehensive bidimensional gas chromatography, hyphenated with a low‐cost quadrupole mass spectrometer (GCxGC‐QMS). The second chromatographic dimension was operated in a dual configuration, consisting of two parallel secondary columns, one being connected to the QMS, the other to a flame ionization detector (FID). This not only allowed optimization of the chromatographic gas flows when compared to the usual single second dimension, but it also enabled the use of the FID signal to extend the quantification range from 2 to 10, 000 mg/kg. The QMS was used at a low level (2‐100 mg/kg), where coelutions are frequent, and the FID was used for the most abundant analytes (100‐10, 000 mg/kg) with a low risk of significant interferences. To assess the identity and purity of the analyte peak at low level, we propose a strategy and summarize it in a decisional tree. To our knowledge, this represents the first fully developed quantification method based on a GCx2GC‐QMS/FID system. In contrast to other methods, it enables the quantification of a wide variety of analytes in fragrances in a single run, without requiring a series of sample dilutions to match the calibration range. Abstract : We describe a procedure to quantify regulated fragrance allergens based on comprehensive bidimensional gas chromatography, hyphenated with a low‐cost quadrupole mass spectrometer. The second chromatographic dimension is operated in a dual configuration, consisting of two columns in parallel, one being connectedto the MS, the other to a flame ionization detector. The former is used at low levels, the latter extends the quantification range up to 10, 000 mg/kg. The peak identity is checked using a decisional tree. … (more)
- Is Part Of:
- Flavour and fragrance journal. Volume 33:Number 1(2018:Jan.)
- Journal:
- Flavour and fragrance journal
- Issue:
- Volume 33:Number 1(2018:Jan.)
- Issue Display:
- Volume 33, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 33
- Issue:
- 1
- Issue Sort Value:
- 2018-0033-0001-0000
- Page Start:
- 63
- Page End:
- 74
- Publication Date:
- 2017-10-29
- Subjects:
- comprehensive bidimensional gas chromatography -- fragrance allergens -- mass spectrometry -- parallel dual secondary column -- quantification
Flavor -- Periodicals
Odors -- Periodicals
Smell -- Periodicals
668.54 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/ffj.3416 ↗
- Languages:
- English
- ISSNs:
- 0882-5734
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3950.047000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5465.xml