A membrane-based fluorescence-quenching immunochromatographic sensor for the rapid detection of tetrodotoxin. (November 2017)
- Record Type:
- Journal Article
- Title:
- A membrane-based fluorescence-quenching immunochromatographic sensor for the rapid detection of tetrodotoxin. (November 2017)
- Main Title:
- A membrane-based fluorescence-quenching immunochromatographic sensor for the rapid detection of tetrodotoxin
- Authors:
- Shen, Haicong
Zhang, Shiwei
Fu, Qiangqiang
Xiao, Wei
Wang, Shifeng
Yu, Shiting
Xiao, Meng
Bian, Hongfen
Tang, Yong - Abstract:
- Abstract: A membrane-based fluorescence-quenching immunochromatographic sensor (FQ-ICS) was developed to detect tetrodotoxin (TTX) in as little as 12 min by utilizing fluorescence resonance energy transfer (FRET). Compared with traditional ICS for detecting TTX, this FQ-ICS provided a positive readout of the signal intensity as well as higher sensitivity. The signal detected during tests increased along with increasing TTX concentrations within a determinate concentration range. The limit of detection (LOD) of the method was 0.78 ng/mL, a value more than 20 times lower than the latest reported value using colloidal gold strips for TTX detection. Furthermore, the detection linear range (DLR) was 3.13–50 ng/mL. Recovery rates for the FQ-ICS used to detect TTX in spiked samples ranged from 61.3% to 70.4%. These results indicate that the FQ-ICS is highly sensitive and suitable for the rapid detection of TTX. Highlights: A fluorescence-quenching strip was applied to rapid, positive readout, and high sensitive tetrodotoxin detection. This strip provided a turn-on readout mode of fluorescence signal, which was more consumer-friendly. The visual detection limit of the strip was 20 times lower than colloidal gold strip for tetrodotoxin detection.
- Is Part Of:
- Food control. Volume 81(2017:Nov.)
- Journal:
- Food control
- Issue:
- Volume 81(2017:Nov.)
- Issue Display:
- Volume 81 (2017)
- Year:
- 2017
- Volume:
- 81
- Issue Sort Value:
- 2017-0081-0000-0000
- Page Start:
- 101
- Page End:
- 106
- Publication Date:
- 2017-11
- Subjects:
- Tetrodotoxin -- Immunochromatographic sensor -- Fluorescence quenching -- Positive readout
FQ-ICS fluorescence-quenching immunochromatographic sensor -- TTX tetrodotoxin -- FRET fluorescence resonance energy transfer -- LOD detection limit -- DLR detection linear range -- LD50 median lethal dose -- MBA mouse bioassays -- LC-MS liquid chromatography-mass spectrometry -- SPR surface plasmon resonance -- ECL electrochemiluminescence sensor -- ELISA enzyme-linked immunosorbent assay -- LFICS lateral flow immunochromatographic sensors -- FQ-ICS fluorescence quenching immunochromatographic sensor -- FM Fluorescent microsphere -- AuNPs gold nanoparticles -- mAb monoclonal antibody -- AuNPs-mAb gold nanoparticles labeled mAb -- FM-BSA-TTX Fluorescent microsphere labeled BSA-TTX -- FM-BSA Fluorescent microsphere labeled BSA
Food -- Quality -- Periodicals
Food -- Analysis -- Periodicals
Food handling -- Periodicals
Food industry and trade -- Quality control -- Periodicals
Aliments -- Industrie et commerce -- Qualité -- Contrôle -- Périodiques
Aliments -- Qualité -- Périodiques
Aliments -- Analyse -- Périodiques
Hygiène alimentaire -- Périodiques
Food -- Analysis
Food handling
Food -- Quality
Periodicals
Electronic journals
664.07 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09567135 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.foodcont.2017.06.001 ↗
- Languages:
- English
- ISSNs:
- 0956-7135
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3977.291500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2869.xml