Placental magnetic resonance imaging T2* measurements in normal pregnancies and in those complicated by fetal growth restriction. (June 2016)
- Record Type:
- Journal Article
- Title:
- Placental magnetic resonance imaging T2* measurements in normal pregnancies and in those complicated by fetal growth restriction. (June 2016)
- Main Title:
- Placental magnetic resonance imaging T2* measurements in normal pregnancies and in those complicated by fetal growth restriction
- Authors:
- Sinding, M.
Peters, D. A.
Frøkjær, J. B.
Christiansen, O. B.
Petersen, A.
Uldbjerg, N.
Sørensen, A. - Abstract:
- Abstract : Linked Comment: Ultrasound Obstet Gynecol 2016; 47: 673–673 ABSTRACT: Objectives: The magnetic resonance imaging (MRI) variable transverse relaxation time (T2*) depends on multiple factors, one important one being the presence of deoxyhemoglobin. We aimed to describe placental T2* measurements in normal pregnancies and in those with fetal growth restriction (FGR). Methods: We included 24 normal pregnancies at 24–40 weeks' gestation and four FGR cases with an estimated fetal weight below the 1 st centile. Prior to MRI, an ultrasound examination, including Doppler flow measurements, was performed. The T2* value was calculated using a gradient echo MRI sequence with readout at 16 different echo times. In normal pregnancies, repeat T2* measurements were performed and interobserver reproducibility was assessed in order to estimate the reproducibility of the method. Placental histological examination was performed in the FGR cases. Results: The method was robust regarding the technical and interobserver reproducibility. However, some slice‐to‐slice variation existed owing to the heterogeneous nature of the normal placenta. We therefore based T2* estimations on the average of two slices from each placenta. In normal pregnancies, the placental T2* value decreased significantly with increasing gestational age, with mean ± SD values of 120 ± 17 ms at 24 weeks' gestation, 84 ± 16 ms at 32 weeks and 47 ± 17 ms at 40 weeks. Three FGR cases had abnormal Doppler flow,Abstract : Linked Comment: Ultrasound Obstet Gynecol 2016; 47: 673–673 ABSTRACT: Objectives: The magnetic resonance imaging (MRI) variable transverse relaxation time (T2*) depends on multiple factors, one important one being the presence of deoxyhemoglobin. We aimed to describe placental T2* measurements in normal pregnancies and in those with fetal growth restriction (FGR). Methods: We included 24 normal pregnancies at 24–40 weeks' gestation and four FGR cases with an estimated fetal weight below the 1 st centile. Prior to MRI, an ultrasound examination, including Doppler flow measurements, was performed. The T2* value was calculated using a gradient echo MRI sequence with readout at 16 different echo times. In normal pregnancies, repeat T2* measurements were performed and interobserver reproducibility was assessed in order to estimate the reproducibility of the method. Placental histological examination was performed in the FGR cases. Results: The method was robust regarding the technical and interobserver reproducibility. However, some slice‐to‐slice variation existed owing to the heterogeneous nature of the normal placenta. We therefore based T2* estimations on the average of two slices from each placenta. In normal pregnancies, the placental T2* value decreased significantly with increasing gestational age, with mean ± SD values of 120 ± 17 ms at 24 weeks' gestation, 84 ± 16 ms at 32 weeks and 47 ± 17 ms at 40 weeks. Three FGR cases had abnormal Doppler flow, histological signs of maternal hypoperfusion and a reduced T2* value ( Z ‐score < –3.5). In the fourth FGR case, Doppler flow, placental histology and T2* value ( Z ‐score, −0.34) were normal. Conclusions: The established reference values for placental T2* may be clinically useful, as T2* values were significantly lower in FGR cases with histological signs of maternal hypoperfusion. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. … (more)
- Is Part Of:
- Ultrasound in obstetrics & gynecology. Volume 47:Number 6(2016)
- Journal:
- Ultrasound in obstetrics & gynecology
- Issue:
- Volume 47:Number 6(2016)
- Issue Display:
- Volume 47, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 47
- Issue:
- 6
- Issue Sort Value:
- 2016-0047-0006-0000
- Page Start:
- 748
- Page End:
- 754
- Publication Date:
- 2016-06
- Subjects:
- fetal growth restriction -- MRI -- placenta -- reproducibility -- T2* -- transverse relaxation time
Ultrasonics in obstetrics -- Periodicals
Generative organs, Female -- Diseases -- Diagnosis -- Periodicals
Diagnosis, Ultrasonic -- Periodicals
Genital Diseases, Female -- ultrasonography -- Periodicals
Ultrasonography, Prenatal -- Periodicals
618.047543 - Journal URLs:
- http://obgyn.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1469-0705/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/uog.14917 ↗
- Languages:
- English
- ISSNs:
- 0960-7692
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9082.815300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1485.xml