X-ray micro-computed tomography (μCT) for non-destructive characterisation of food microstructure. (January 2016)
- Record Type:
- Journal Article
- Title:
- X-ray micro-computed tomography (μCT) for non-destructive characterisation of food microstructure. (January 2016)
- Main Title:
- X-ray micro-computed tomography (μCT) for non-destructive characterisation of food microstructure
- Authors:
- Schoeman, Letitia
Williams, Paul
du Plessis, Anton
Manley, Marena - Abstract:
- Abstract: Background: Food microstructure can be visualised by a wide range of microscopic techniques, however these methods are usually destructive and require sample preparation. X-ray micro-computed tomography (μCT) provides an alternative as it is non-invasive, non-destructive and requires no sample preparation. It characterises structures three-dimensionally, allowing evaluation of microstructural changes at resolutions as high as a few hundred nanometres. After the discovery of X-rays in 1895, X-ray computed tomography (CT) was developed and introduced into clinical practices in the 1970s. The first X-ray μCT food application, to detect the maturity of green tomatoes, followed in 1991. Scope and approach: This review aims to provide an overview of the basic principles of X-ray μCT, the different systems, image processing and analysis as well as image texture analysis. Food applications are highlighted and the review concludes with future trends of X-ray μCT. Key findings and conclusions: The controlled production and stability of microstructure is of great interest to the food industry. Both laboratory μCT and synchrotron systems are becoming more common and thus will lead to imaging in three dimensions at a micron scale playing a much bigger role in future food studies. Limitations include operator dependency, time and cost constraints and imaging artefacts. Technological and computational progress, however, encourages the growth of this technique in food science.Abstract: Background: Food microstructure can be visualised by a wide range of microscopic techniques, however these methods are usually destructive and require sample preparation. X-ray micro-computed tomography (μCT) provides an alternative as it is non-invasive, non-destructive and requires no sample preparation. It characterises structures three-dimensionally, allowing evaluation of microstructural changes at resolutions as high as a few hundred nanometres. After the discovery of X-rays in 1895, X-ray computed tomography (CT) was developed and introduced into clinical practices in the 1970s. The first X-ray μCT food application, to detect the maturity of green tomatoes, followed in 1991. Scope and approach: This review aims to provide an overview of the basic principles of X-ray μCT, the different systems, image processing and analysis as well as image texture analysis. Food applications are highlighted and the review concludes with future trends of X-ray μCT. Key findings and conclusions: The controlled production and stability of microstructure is of great interest to the food industry. Both laboratory μCT and synchrotron systems are becoming more common and thus will lead to imaging in three dimensions at a micron scale playing a much bigger role in future food studies. Limitations include operator dependency, time and cost constraints and imaging artefacts. Technological and computational progress, however, encourages the growth of this technique in food science. Highlights: Food microstructure can be visualised using X-ray micro-computed tomography (μCT). X-ray μCT is a non-invasive and non-destructive 3D imaging technique. Computational progress encourages the growth of this technique in food science. X-ray μCT allows evaluation at resolutions as high as a few hundred nanometres. … (more)
- Is Part Of:
- Trends in food science & technology. Volume 47(2016)
- Journal:
- Trends in food science & technology
- Issue:
- Volume 47(2016)
- Issue Display:
- Volume 47, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 47
- Issue:
- 2016
- Issue Sort Value:
- 2016-0047-2016-0000
- Page Start:
- 10
- Page End:
- 24
- Publication Date:
- 2016-01
- Subjects:
- Food microstructure -- X-ray micro-computed tomography (μCT) -- Non-destructive -- Three-dimensional -- Food applications
Food industry and trade -- Periodicals
Food -- Biotechnology -- Periodicals
664.005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09242244 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.tifs.2015.10.016 ↗
- Languages:
- English
- ISSNs:
- 0924-2244
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9049.593000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2764.xml