Association between integrated backscatter and arrhythmia in patients with ischemic dilated cardiomyopathy. Issue 6 (21st May 2021)
- Record Type:
- Journal Article
- Title:
- Association between integrated backscatter and arrhythmia in patients with ischemic dilated cardiomyopathy. Issue 6 (21st May 2021)
- Main Title:
- Association between integrated backscatter and arrhythmia in patients with ischemic dilated cardiomyopathy
- Authors:
- Karaayvaz, Ekrem Bilal
Engin, Berat
Yalin, Kivanc
Ozer, Pelin Karaca
Baykiz, Derya
Bilge, Ahmet Kaya - Abstract:
- Abstract: Background: Ventricular scars due to myocardial infarction provide a substrate for ventricular arrhythmias, and cardiac magnetic resonance (CMR) is the golden standard for the quantification of scar tissue magnitude. CMR has still limitations with patients with ICD despite ICD's becoming MR‐compatible. We investigated the association between calibrated integrated backscatter (cIBS) and arrhythmia frequency in patients with ICD. Methods: Thirty‐two ischemic dilated cardiomyopathy (ICM) patients with VVI‐ICD (mean age 66.56 ± 9.05, 28 male, and four female) were divided into three groups according to their arrhythmia frequency (ventricular arrhythmia—[VA ‐], VA + [VA +], and arrhythmia storm [AS]). Then with transthoracic echocardiography (TTE), all patients' cIBS values were calculated and these values were compared with the patients' arrhythmia frequency. Results: cIBS values of patients with VA + and AS were significantly higher in the apical‐septal (0.66 ± 0.11 vs. 0.50 ± 0.16, p = .008) and apical‐lateral (0.62 ± 0.19 vs. 0.46 ± 0.18, p = .041) segments compared to those of patients with VA ‐. The cIBS values of apical‐septal (0.50 ± 0.16 vs. 0.65 ± 0.08 vs. 0.66 ± 0.13 respectively, p = .032) and apical‐anterior (0.53 ± 0.22 vs. 0.48 ± 0.17 vs. 0.79 ± 0.23 respectively, p = .03) segments were significantly different between the groups. Furthermore, in the post hoc analysis, the difference was significantly higher in VA + than VA ‐ in the apical‐septalAbstract: Background: Ventricular scars due to myocardial infarction provide a substrate for ventricular arrhythmias, and cardiac magnetic resonance (CMR) is the golden standard for the quantification of scar tissue magnitude. CMR has still limitations with patients with ICD despite ICD's becoming MR‐compatible. We investigated the association between calibrated integrated backscatter (cIBS) and arrhythmia frequency in patients with ICD. Methods: Thirty‐two ischemic dilated cardiomyopathy (ICM) patients with VVI‐ICD (mean age 66.56 ± 9.05, 28 male, and four female) were divided into three groups according to their arrhythmia frequency (ventricular arrhythmia—[VA ‐], VA + [VA +], and arrhythmia storm [AS]). Then with transthoracic echocardiography (TTE), all patients' cIBS values were calculated and these values were compared with the patients' arrhythmia frequency. Results: cIBS values of patients with VA + and AS were significantly higher in the apical‐septal (0.66 ± 0.11 vs. 0.50 ± 0.16, p = .008) and apical‐lateral (0.62 ± 0.19 vs. 0.46 ± 0.18, p = .041) segments compared to those of patients with VA ‐. The cIBS values of apical‐septal (0.50 ± 0.16 vs. 0.65 ± 0.08 vs. 0.66 ± 0.13 respectively, p = .032) and apical‐anterior (0.53 ± 0.22 vs. 0.48 ± 0.17 vs. 0.79 ± 0.23 respectively, p = .03) segments were significantly different between the groups. Furthermore, in the post hoc analysis, the difference was significantly higher in VA + than VA ‐ in the apical‐septal segment and higher in AS than VA + in apical‐anterior segments. Conclusion: Our findings suggest an association between the cIBS values and arrhythmia frequency in the study group. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 44:Issue 6(2021)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 44:Issue 6(2021)
- Issue Display:
- Volume 44, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 44
- Issue:
- 6
- Issue Sort Value:
- 2021-0044-0006-0000
- Page Start:
- 1010
- Page End:
- 1017
- Publication Date:
- 2021-05-21
- Subjects:
- arrhythmia frequency -- defibrillation—ICD -- integrated backscatter -- ischemic dilated cardiomyopathy
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.14257 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27147.xml