Optic Nerve Sheath Diameter Ultrasound for Raised Intracranial Pressure: A Literature Review and Meta‐analysis of its Diagnostic Accuracy. (24th April 2021)
- Record Type:
- Journal Article
- Title:
- Optic Nerve Sheath Diameter Ultrasound for Raised Intracranial Pressure: A Literature Review and Meta‐analysis of its Diagnostic Accuracy. (24th April 2021)
- Main Title:
- Optic Nerve Sheath Diameter Ultrasound for Raised Intracranial Pressure
- Authors:
- Aletreby, Waleed
Alharthy, Abdulrahman
Brindley, Peter G
Kutsogiannis, Demetrios J.
Faqihi, Fahad
Alzayer, Waseem
Balhahmar, Abdullah
Soliman, Ibrahim
Hamido, Hend
Alqahtani, Saleh A
Karakitsos, Dimitrios
Blaivas, Michael - Abstract:
- Abstract : Optic nerve sheath diameter (ONSD) ultrasound is becoming increasingly more popular for estimating raised intracranial pressure (ICP). We performed a systematic review and analysis of the diagnostic accuracy of ONSD when compared to the standard invasive ICP measurement. Method: We performed a systematic search of PUBMED and EMBASE for studies including adult patients with suspected elevated ICP and comparing sonographic ONSD measurement to a standard invasive method. Quality of studies was assessed using the QUADAS‐2 tool by two independent authors. We used a bivariate model of random effects to summarize pooled sensitivity, specificity, and diagnostic odds ratio (DOR). Heterogeneity was investigated by meta‐regression and sub‐group analyses. Results: We included 18 prospective studies (16 studies including 619 patients for primary outcome). Only one study was of low quality, and there was no apparent publication bias. Pooled sensitivity was 0.9 [95% confidence intervals (CI): 0.85–0.94], specificity was 0.85 (95% CI: 0.8–0.89), and DOR was 46.7 (95% CI: 26.2–83.2) with partial evidence of heterogeneity. The Area‐Under‐the‐Curve of the summary Receiver‐Operator‐Curve was 0.93 (95% CI: 0.91–0.95, P < .05). No covariates were significant in the meta‐regression. Subgroup analysis of severe traumatic brain injury and parenchymal ICP found no heterogeneity. ICP and ONSD had a correlation coefficient of 0.7 (95% CI: 0.63–0.76, P < .05). Conclusion: ONSD is a usefulAbstract : Optic nerve sheath diameter (ONSD) ultrasound is becoming increasingly more popular for estimating raised intracranial pressure (ICP). We performed a systematic review and analysis of the diagnostic accuracy of ONSD when compared to the standard invasive ICP measurement. Method: We performed a systematic search of PUBMED and EMBASE for studies including adult patients with suspected elevated ICP and comparing sonographic ONSD measurement to a standard invasive method. Quality of studies was assessed using the QUADAS‐2 tool by two independent authors. We used a bivariate model of random effects to summarize pooled sensitivity, specificity, and diagnostic odds ratio (DOR). Heterogeneity was investigated by meta‐regression and sub‐group analyses. Results: We included 18 prospective studies (16 studies including 619 patients for primary outcome). Only one study was of low quality, and there was no apparent publication bias. Pooled sensitivity was 0.9 [95% confidence intervals (CI): 0.85–0.94], specificity was 0.85 (95% CI: 0.8–0.89), and DOR was 46.7 (95% CI: 26.2–83.2) with partial evidence of heterogeneity. The Area‐Under‐the‐Curve of the summary Receiver‐Operator‐Curve was 0.93 (95% CI: 0.91–0.95, P < .05). No covariates were significant in the meta‐regression. Subgroup analysis of severe traumatic brain injury and parenchymal ICP found no heterogeneity. ICP and ONSD had a correlation coefficient of 0.7 (95% CI: 0.63–0.76, P < .05). Conclusion: ONSD is a useful adjunct in ICP evaluation but is currently not a replacement for invasive methods where they are feasible. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 41:Number 3(2022)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 41:Number 3(2022)
- Issue Display:
- Volume 41, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 41
- Issue:
- 3
- Issue Sort Value:
- 2022-0041-0003-0000
- Page Start:
- 585
- Page End:
- 595
- Publication Date:
- 2021-04-24
- Subjects:
- optic nerve sheath diameter -- ultrasound -- intracranial pressure -- meta‐analysis
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jum.15732 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27145.xml