Generalisability and performance of an OCT-based deep learning classifier for community-based and hospital-based detection of gonioscopic angle closure. Issue 4 (20th October 2021)
- Record Type:
- Journal Article
- Title:
- Generalisability and performance of an OCT-based deep learning classifier for community-based and hospital-based detection of gonioscopic angle closure. Issue 4 (20th October 2021)
- Main Title:
- Generalisability and performance of an OCT-based deep learning classifier for community-based and hospital-based detection of gonioscopic angle closure
- Authors:
- Randhawa, Jasmeen
Chiang, Michael
Porporato, Natalia
Pardeshi, Anmol A
Dredge, Justin
Apolo Aroca, Galo
Tun, Tin A
Quah, Joanne HuiMin
Tan, Marcus
Higashita, Risa
Aung, Tin
Varma, Rohit
Xu, Benjamin Y - Abstract:
- Abstract : Purpose: To assess the generalisability and performance of a deep learning classifier for automated detection of gonioscopic angle closure in anterior segment optical coherence tomography (AS-OCT) images. Methods: A convolutional neural network (CNN) model developed using data from the Chinese American Eye Study (CHES) was used to detect gonioscopic angle closure in AS-OCT images with reference gonioscopy grades provided by trained ophthalmologists. Independent test data were derived from the population-based CHES, a community-based clinic in Singapore, and a hospital-based clinic at the University of Southern California (USC). Classifier performance was evaluated with receiver operating characteristic curve and area under the receiver operating characteristic curve (AUC) metrics. Interexaminer agreement between the classifier and two human examiners at USC was calculated using Cohen's kappa coefficients. Results: The classifier was tested using 640 images (311 open and 329 closed) from 127 Chinese Americans, 10 165 images (9595 open and 570 closed) from 1318 predominantly Chinese Singaporeans and 300 images (234 open and 66 closed) from 40 multiethnic USC patients. The classifier achieved similar performance in the CHES (AUC=0.917), Singapore (AUC=0.894) and USC (AUC=0.922) cohorts. Standardising the distribution of gonioscopy grades across cohorts produced similar AUC metrics (range 0.890–0.932). The agreement between the CNN classifier and two human examinersAbstract : Purpose: To assess the generalisability and performance of a deep learning classifier for automated detection of gonioscopic angle closure in anterior segment optical coherence tomography (AS-OCT) images. Methods: A convolutional neural network (CNN) model developed using data from the Chinese American Eye Study (CHES) was used to detect gonioscopic angle closure in AS-OCT images with reference gonioscopy grades provided by trained ophthalmologists. Independent test data were derived from the population-based CHES, a community-based clinic in Singapore, and a hospital-based clinic at the University of Southern California (USC). Classifier performance was evaluated with receiver operating characteristic curve and area under the receiver operating characteristic curve (AUC) metrics. Interexaminer agreement between the classifier and two human examiners at USC was calculated using Cohen's kappa coefficients. Results: The classifier was tested using 640 images (311 open and 329 closed) from 127 Chinese Americans, 10 165 images (9595 open and 570 closed) from 1318 predominantly Chinese Singaporeans and 300 images (234 open and 66 closed) from 40 multiethnic USC patients. The classifier achieved similar performance in the CHES (AUC=0.917), Singapore (AUC=0.894) and USC (AUC=0.922) cohorts. Standardising the distribution of gonioscopy grades across cohorts produced similar AUC metrics (range 0.890–0.932). The agreement between the CNN classifier and two human examiners (Ҡ=0.700 and 0.704) approximated interexaminer agreement (Ҡ=0.693) in the USC cohort. Conclusion: An OCT-based deep learning classifier demonstrated consistent performance detecting gonioscopic angle closure across three independent patient populations. This automated method could aid ophthalmologists in the assessment of angle status in diverse patient populations. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 107:Issue 4(2023)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 107:Issue 4(2023)
- Issue Display:
- Volume 107, Issue 4 (2023)
- Year:
- 2023
- Volume:
- 107
- Issue:
- 4
- Issue Sort Value:
- 2023-0107-0004-0000
- Page Start:
- 511
- Page End:
- 517
- Publication Date:
- 2021-10-20
- Subjects:
- glaucoma -- anterior chamber -- diagnostic tests/investigation -- imaging
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2021-319470 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27137.xml