Use of the Medtronic Microvascular Plug 7Q for transcatheter closure of large patent ductus arteriosus in infants weighing less than 2.5 kg. Issue 5 (30th January 2022)
- Record Type:
- Journal Article
- Title:
- Use of the Medtronic Microvascular Plug 7Q for transcatheter closure of large patent ductus arteriosus in infants weighing less than 2.5 kg. Issue 5 (30th January 2022)
- Main Title:
- Use of the Medtronic Microvascular Plug 7Q for transcatheter closure of large patent ductus arteriosus in infants weighing less than 2.5 kg
- Authors:
- Nasef, Mohamed Al
O'Sullivan, Donnchadh
Ng, Li Yen
Walsh, Kevin P.
Oslizlok, Paul
McCrossan, Brian
Kenny, Damien
Sathanandam, Shyam - Abstract:
- Abstract: Background: The sole Food and Drug Administration‐approved device for transcatheter closure of the patent arterial duct in premature infants is indicated for patent ductus arteriosus (PDAs) ≤ 4 mm in diameter. We report a two‐center experience with transcatheter closure of large PDAs (>4 mm) in infants weighing <2.5 kg using the Microvascular Plug 7Q (MVP‐7Q) device. Methods: This is a retrospective review of departmental databases and medical charts to define patient cohort and report demographic, procedural, and follow‐up data. Results: Twenty‐two patients (12 male) with a median gestational age and birthweight of 25.5 weeks (interquartile range [IQR] = 24–28) and 800 g (572–1075), respectively, underwent attempted PDA occlusion with the MVP‐7Q using a transvenous approach. The median age and weight at the time of PDA occlusion was 32 days (IQR = 24–28) and 1100 g (IQR = 960–1700), respectively. The median PDA length was 12 mm (IQR = 11–12.65). The median PDA diameters at the aortic and pulmonary ends were 5.1 (IQR = 4.9–5.5) and 4.8 mm (IQR = 4.6–5.3), respectively. Successful device occlusion was achieved in 20 patients (91%). There were two failed attempts: One due to inappropriate sizing, and the other secondary to left pulmonary artery stenosis. There were no procedural complications and no residual shunting on follow‐up. Conclusions: The MVP‐7Q is safe and effective for transcatheter closure of large (>4 mm) PDAs in infants <2.5 kg. The lack of retentionAbstract: Background: The sole Food and Drug Administration‐approved device for transcatheter closure of the patent arterial duct in premature infants is indicated for patent ductus arteriosus (PDAs) ≤ 4 mm in diameter. We report a two‐center experience with transcatheter closure of large PDAs (>4 mm) in infants weighing <2.5 kg using the Microvascular Plug 7Q (MVP‐7Q) device. Methods: This is a retrospective review of departmental databases and medical charts to define patient cohort and report demographic, procedural, and follow‐up data. Results: Twenty‐two patients (12 male) with a median gestational age and birthweight of 25.5 weeks (interquartile range [IQR] = 24–28) and 800 g (572–1075), respectively, underwent attempted PDA occlusion with the MVP‐7Q using a transvenous approach. The median age and weight at the time of PDA occlusion was 32 days (IQR = 24–28) and 1100 g (IQR = 960–1700), respectively. The median PDA length was 12 mm (IQR = 11–12.65). The median PDA diameters at the aortic and pulmonary ends were 5.1 (IQR = 4.9–5.5) and 4.8 mm (IQR = 4.6–5.3), respectively. Successful device occlusion was achieved in 20 patients (91%). There were two failed attempts: One due to inappropriate sizing, and the other secondary to left pulmonary artery stenosis. There were no procedural complications and no residual shunting on follow‐up. Conclusions: The MVP‐7Q is safe and effective for transcatheter closure of large (>4 mm) PDAs in infants <2.5 kg. The lack of retention disks may help with avoiding impingement on surrounding vessels. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 99:Issue 5(2022)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 99:Issue 5(2022)
- Issue Display:
- Volume 99, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 99
- Issue:
- 5
- Issue Sort Value:
- 2022-0099-0005-0000
- Page Start:
- 1545
- Page End:
- 1550
- Publication Date:
- 2022-01-30
- Subjects:
- coil/device/transcatheter -- congenital heart disease -- embolization -- endovascular -- intervention -- pediatrics
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.30105 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 27128.xml