Perfusion MRI using endogenous deoxyhemoglobin as a contrast agent: Preliminary data. Issue 6 (22nd October 2021)
- Record Type:
- Journal Article
- Title:
- Perfusion MRI using endogenous deoxyhemoglobin as a contrast agent: Preliminary data. Issue 6 (22nd October 2021)
- Main Title:
- Perfusion MRI using endogenous deoxyhemoglobin as a contrast agent: Preliminary data
- Authors:
- Poublanc, Julien
Sobczyk, Olivia
Shafi, Reema
Sayin, Ece Su
Schulman, Jacob
Duffin, James
Uludag, Kamil
Wood, John C.
Vu, Chau
Dharmakumar, Rohan
Fisher, Joseph A.
Mikulis, David J. - Abstract:
- Abstract : Purpose: To demonstrate the feasibility of mapping cerebral perfusion metrics with BOLD MRI during modulation of pulmonary venous oxygen saturation. Methods: A gas blender with a sequential gas delivery breathing circuit was used to implement rapid isocapnic changes in the partial pressure of oxygen of the arterial blood. Partial pressure of oxygen was initially lowered to a baseline of 40 mmHg. It was then rapidly raised to 95 mmHg for 20 s before rapidly returning to baseline. The induced cerebral changes in deoxyhemoglobin concentration were tracked over time using BOLD MRI in 6 healthy subjects and 1 patient with cerebral steno‐occlusive disease. BOLD signal change, contrast‐to‐noise ratio, and time delay metrics were calculated. Perfusion metrics such as mean transit time, relative cerebral blood volume, and relative cerebral blood flow were calculated using a parametrized method with a mono‐exponential residue function. An arterial input function from within the middle cerebral artery was used to scale relative cerebral blood volume and calculate absolute cerebral blood volume and cerebral blood flow. Results: In normal subjects, average gray and white matter were: BOLD change = 6.3 ± 1.2% and 2.5 ± 0.6%, contrast‐to‐noise ratio = 4.3 ± 1.3 and 2.6 ± 0.7, time delay = 2.3 ± 0.6 s and 3.6 ± 0.7 s, mean transit time = 3.9 ± 0.6 s and 5.5 ± 0.6 s, relative cerebral blood volume = 3.7 ± 0.9 and 1.6 ± 0.4, relative cerebral blood flow = 70.1 ± 8.3 and 20.6 ± 4.0,Abstract : Purpose: To demonstrate the feasibility of mapping cerebral perfusion metrics with BOLD MRI during modulation of pulmonary venous oxygen saturation. Methods: A gas blender with a sequential gas delivery breathing circuit was used to implement rapid isocapnic changes in the partial pressure of oxygen of the arterial blood. Partial pressure of oxygen was initially lowered to a baseline of 40 mmHg. It was then rapidly raised to 95 mmHg for 20 s before rapidly returning to baseline. The induced cerebral changes in deoxyhemoglobin concentration were tracked over time using BOLD MRI in 6 healthy subjects and 1 patient with cerebral steno‐occlusive disease. BOLD signal change, contrast‐to‐noise ratio, and time delay metrics were calculated. Perfusion metrics such as mean transit time, relative cerebral blood volume, and relative cerebral blood flow were calculated using a parametrized method with a mono‐exponential residue function. An arterial input function from within the middle cerebral artery was used to scale relative cerebral blood volume and calculate absolute cerebral blood volume and cerebral blood flow. Results: In normal subjects, average gray and white matter were: BOLD change = 6.3 ± 1.2% and 2.5 ± 0.6%, contrast‐to‐noise ratio = 4.3 ± 1.3 and 2.6 ± 0.7, time delay = 2.3 ± 0.6 s and 3.6 ± 0.7 s, mean transit time = 3.9 ± 0.6 s and 5.5 ± 0.6 s, relative cerebral blood volume = 3.7 ± 0.9 and 1.6 ± 0.4, relative cerebral blood flow = 70.1 ± 8.3 and 20.6 ± 4.0, cerebral blood flow volume = 4.1 ± 0.9 mL/100 g and 1.8 ± 0.5 mL/100 g, and cerebral blood flow = 97.2 ± 18.7 mL/100 g/min and 28.7 ± 5.9 mL/100 g/min. Conclusion: This study demonstrates that induced abrupt changes in deoxyhemoglobin can function as a noninvasive vascular contrast agent that may be used for cerebral perfusion imaging. Abstract : Click here for author‐reader discussions … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 86:Issue 6(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 86:Issue 6(2021)
- Issue Display:
- Volume 86, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 86
- Issue:
- 6
- Issue Sort Value:
- 2021-0086-0006-0000
- Page Start:
- 3012
- Page End:
- 3021
- Publication Date:
- 2021-10-22
- Subjects:
- cerebral perfusion -- deoxyhemoglobin -- endogenous contrast -- hypoxia -- MRI contrast
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28974 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27129.xml