Technetium‐99m‐MAG3 and technetium‐99m‐DTPA: Renal clearance measured by the constant infusion technique – Old news?. (29th August 2021)
- Record Type:
- Journal Article
- Title:
- Technetium‐99m‐MAG3 and technetium‐99m‐DTPA: Renal clearance measured by the constant infusion technique – Old news?. (29th August 2021)
- Main Title:
- Technetium‐99m‐MAG3 and technetium‐99m‐DTPA: Renal clearance measured by the constant infusion technique – Old news?
- Authors:
- Østergaard, Ann Mai
Langaa, Stine S.
Vrist, Marie H.
Mose, Frank H.
Bech, Jesper N.
Fynbo, Claire A.
Theil, Jørn
Ejlersen, June A. - Abstract:
- Abstract: Background: Accurate, precise and straightforward methods for measuring glomerular filtration rate (GFR) and/or renal plasma flow (RPF) are still in demand today. The time‐consuming constant infusion technique (CIT) is the gold standard and preferred for research, whereas the simple, but less precise, single injection technique (SIT) is used in clinical settings. This study investigated the use of 99m Tc‐DTPA and 99m Tc‐MAG3 by CIT as a measure of renal function. We developed and evaluated a model to balance the primer dose and infusion rate in an attempt to obtain plasma steady state as quickly as possible. Methods: 14 healthy subjects received 99m Tc‐DTPA and 6 hypertensive patients received 99m Tc‐MAG3 in a standardized protocol. All participants had an eGFR above 60 ml/min and none had fluid retention. An intravenous primer injection of the relevant tracer was followed by a sustained infusion over 4.5 h with the same radiopharmaceutical. Blood and urine samples were collected at fixed intervals. Results: 99m Tc‐DTPA clearance reached steady state after 210 min (plasma clearance 78 ± 18 ml/min, urine clearance 110 ± 28 ml/min), whereas 99m Tc‐MAG3 clearance achieved steady state after 150 min (plasma clearance 212 ± 56 ml/min, urine clearance 233 ± 59 ml/min). Conclusion: Constant infusion technique with fixed primer and infusion rate using 99m Tc‐MAG3 is feasible for research purposes. The longer time for reaching plasma steady state using 99m Tc‐DTPA makesAbstract: Background: Accurate, precise and straightforward methods for measuring glomerular filtration rate (GFR) and/or renal plasma flow (RPF) are still in demand today. The time‐consuming constant infusion technique (CIT) is the gold standard and preferred for research, whereas the simple, but less precise, single injection technique (SIT) is used in clinical settings. This study investigated the use of 99m Tc‐DTPA and 99m Tc‐MAG3 by CIT as a measure of renal function. We developed and evaluated a model to balance the primer dose and infusion rate in an attempt to obtain plasma steady state as quickly as possible. Methods: 14 healthy subjects received 99m Tc‐DTPA and 6 hypertensive patients received 99m Tc‐MAG3 in a standardized protocol. All participants had an eGFR above 60 ml/min and none had fluid retention. An intravenous primer injection of the relevant tracer was followed by a sustained infusion over 4.5 h with the same radiopharmaceutical. Blood and urine samples were collected at fixed intervals. Results: 99m Tc‐DTPA clearance reached steady state after 210 min (plasma clearance 78 ± 18 ml/min, urine clearance 110 ± 28 ml/min), whereas 99m Tc‐MAG3 clearance achieved steady state after 150 min (plasma clearance 212 ± 56 ml/min, urine clearance 233 ± 59 ml/min). Conclusion: Constant infusion technique with fixed primer and infusion rate using 99m Tc‐MAG3 is feasible for research purposes. The longer time for reaching plasma steady state using 99m Tc‐DTPA makes CIT with this tracer less optimal. If the primer/sustained balance can be optimized, for example using a priori SIT information, 99m Tc‐DTPA as tracer for CIT may also be feasible. … (more)
- Is Part Of:
- Clinical physiology and functional imaging. Volume 41:Number 6(2021)
- Journal:
- Clinical physiology and functional imaging
- Issue:
- Volume 41:Number 6(2021)
- Issue Display:
- Volume 41, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 41
- Issue:
- 6
- Issue Sort Value:
- 2021-0041-0006-0000
- Page Start:
- 488
- Page End:
- 496
- Publication Date:
- 2021-08-29
- Subjects:
- GFR -- interventional studies -- renal clearance -- renal plasma flow -- tracer kinetics
Physiology, Pathological -- Periodicals
Diagnostic imaging -- Periodicals
612 - Journal URLs:
- http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=cpf ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/cpf.12724 ↗
- Languages:
- English
- ISSNs:
- 1475-0961
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.333520
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27122.xml