Experimental investigation of structural failure during the cooling phase of a fire: Timber columns. (22nd October 2022)
- Record Type:
- Journal Article
- Title:
- Experimental investigation of structural failure during the cooling phase of a fire: Timber columns. (22nd October 2022)
- Main Title:
- Experimental investigation of structural failure during the cooling phase of a fire: Timber columns
- Authors:
- Gernay, Thomas
Zehfuß, Jochen
Brunkhorst, Sven
Robert, Fabienne
Bamonte, Patrick
McNamee, Robert
Mohaine, Siyimane
Franssen, Jean‐Marc - Other Names:
- Gales John Adam guestEditor.
McNamee Robert guestEditor. - Abstract:
- Abstract: This paper describes fire tests on loaded glued laminated timber columns in which the structural response was measured during the heating and cooling phases. Identical columns with 280 × 280 mm 2 cross‐section and 3.7 m length were tested under various heating durations in a standard furnace to investigate integrity to full burnout. Two of the columns were subjected to ISO 834 heating until failure and their measured fire resistance was 55 and 58 min, respectively. Two columns were subjected to 15 min of ISO 834 heating followed by controlled cooling; these columns failed during the cooling phase, respectively after 98 and 153 min. Flame self‐extinction occurred after approximately 40 min while smoldering continued locally. Two columns tested under 10 min of ISO 834 heating both survived the defined heating–cooling exposure. Thermocouples inside the columns show sustained temperature increases for hours after the end of the heating phase. These full‐scale furnace experiments show that timber columns may fail during the cooling phase after exposure to standard heating for about 25% of the standard fire resistance duration. These results, in line with previous numerical predictions, highlight the need for further investigation into fire safety until full burnout for timber structures.
- Is Part Of:
- Fire and materials. Volume 47:Number 4(2023)
- Journal:
- Fire and materials
- Issue:
- Volume 47:Number 4(2023)
- Issue Display:
- Volume 47, Issue 4 (2023)
- Year:
- 2023
- Volume:
- 47
- Issue:
- 4
- Issue Sort Value:
- 2023-0047-0004-0000
- Page Start:
- 445
- Page End:
- 460
- Publication Date:
- 2022-10-22
- Subjects:
- burnout resistance -- cooling phase -- fire resistance -- glued laminated -- structural failure -- timber columns
Fire-testing -- Periodicals
Fire -- Periodicals
Materials -- Periodicals
620.11217 - Journal URLs:
- http://www3.interscience.wiley.com/cgi-bin/jhome/109607601 ↗
http://www3.interscience.wiley.com/cgi-bin/jhome/3189 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/fam.3110 ↗
- Languages:
- English
- ISSNs:
- 0308-0501
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3930.250000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 27110.xml