Novel application of indocyanine green fluorescence imaging for real‐time detection of thrombus in a membrane oxygenator. Issue 10 (12th June 2021)
- Record Type:
- Journal Article
- Title:
- Novel application of indocyanine green fluorescence imaging for real‐time detection of thrombus in a membrane oxygenator. Issue 10 (12th June 2021)
- Main Title:
- Novel application of indocyanine green fluorescence imaging for real‐time detection of thrombus in a membrane oxygenator
- Authors:
- Sakurai, Hironobu
Fujiwara, Tatsuki
Ohuchi, Katsuhiro
Hijikata, Wataru
Inoue, Yusuke
Seki, Haruna
Tahara, Tomoki
Yokota, Sachie
Ogata, Asato
Mizuno, Tomohiro
Arai, Hirokuni - Abstract:
- Abstract: Extracorporeal membrane oxygenation (ECMO) plays an important role in the coronavirus disease 2019 (COVID‐19) pandemic. Management of thrombi in ECMO is generally an important issue; especially in ECMO for COVID‐19 patients who are prone to thrombus formation, the thrombus formation in oxygenators is an unresolved issue, and it is very difficult to deal with. To prevent thromboembolic complications, it is necessary to develop a method for early thrombus detection. We developed a novel method for detailed real‐time observation of thrombi formed in oxygenators using indocyanine green (ICG) fluorescence imaging. The purpose of this study was to verify the efficacy of this novel method through animal experiments. The experiments were performed three times using three pigs equipped with veno‐arterial ECMO comprising a centrifugal pump (CAPIOX SL) and an oxygenator (QUADROX). To create thrombogenic conditions, the pump flow rate was set at 1 L/min without anticoagulation. The diluted ICG (0.025 mg/mL) was intravenously administered at a dose of 10 mL once an hour. A single dose of ICG was 0.25mg. The oxygenator was observed with both an optical detector (PDE‐neo) and the naked eye every hour after measurement initiation for a total of 8 hours. With this dose of ICG, we could observe it by fluorescence imaging for about 15 minutes. Under ICG imaging, the inside of the oxygenator was observed as a white area. A black dot suspected to be the thrombus appeared 6‐8 hoursAbstract: Extracorporeal membrane oxygenation (ECMO) plays an important role in the coronavirus disease 2019 (COVID‐19) pandemic. Management of thrombi in ECMO is generally an important issue; especially in ECMO for COVID‐19 patients who are prone to thrombus formation, the thrombus formation in oxygenators is an unresolved issue, and it is very difficult to deal with. To prevent thromboembolic complications, it is necessary to develop a method for early thrombus detection. We developed a novel method for detailed real‐time observation of thrombi formed in oxygenators using indocyanine green (ICG) fluorescence imaging. The purpose of this study was to verify the efficacy of this novel method through animal experiments. The experiments were performed three times using three pigs equipped with veno‐arterial ECMO comprising a centrifugal pump (CAPIOX SL) and an oxygenator (QUADROX). To create thrombogenic conditions, the pump flow rate was set at 1 L/min without anticoagulation. The diluted ICG (0.025 mg/mL) was intravenously administered at a dose of 10 mL once an hour. A single dose of ICG was 0.25mg. The oxygenator was observed with both an optical detector (PDE‐neo) and the naked eye every hour after measurement initiation for a total of 8 hours. With this dose of ICG, we could observe it by fluorescence imaging for about 15 minutes. Under ICG imaging, the inside of the oxygenator was observed as a white area. A black dot suspected to be the thrombus appeared 6‐8 hours after measurement initiation. The thrombus and the black dot on ICG imaging were finely matched in terms of morphology. Thus, we succeeded in real‐time thrombus detection in an oxygenator using ICG imaging. The combined use of ICG imaging and conventional routine screening tests could compensate for each other's weaknesses and significantly improve the safety of ECMO. Abstract : We successfully performed the real‐time detection of thrombus in an oxygenator during extracorporeal membrane oxygenation using indocyanine green (ICG) fluorescence imaging in an animal experiment with pigs. ICG was intravenously administered, and the oxygenator (QUADROX) was observed with an optical detector (PDE‐neo) every hour for 8 hours after measurement initiation. A black dot suspected to be a thrombus appeared. The thrombus and the black dot on ICG imaging were found to be consistent in terms of morphology. … (more)
- Is Part Of:
- Artificial organs. Volume 45:Issue 10(2021)
- Journal:
- Artificial organs
- Issue:
- Volume 45:Issue 10(2021)
- Issue Display:
- Volume 45, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 45
- Issue:
- 10
- Issue Sort Value:
- 2021-0045-0010-0000
- Page Start:
- 1173
- Page End:
- 1182
- Publication Date:
- 2021-06-12
- Subjects:
- acute animal experiment -- coronavirus disease 2019 -- extracorporeal membrane oxygenation -- indocyanine green fluorescence imaging -- indocyanine green -- oxygenator -- real‐time thrombus detection -- thrombus
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.13999 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 27101.xml