Initial experiences of transapical beating‐heart mitral valve repair with a novel artificial chordal implantation device. Issue 5 (26th February 2022)
- Record Type:
- Journal Article
- Title:
- Initial experiences of transapical beating‐heart mitral valve repair with a novel artificial chordal implantation device. Issue 5 (26th February 2022)
- Main Title:
- Initial experiences of transapical beating‐heart mitral valve repair with a novel artificial chordal implantation device
- Authors:
- Wang, Shouzheng
Meng, Xu
Hu, Shengshou
Sievert, Horst
Xie, Yongquan
Hu, Xiaopeng
Sun, Yi
Luo, Zhiling
Zhou, Hongyan
Zhang, Guimin
Pan, Xiangbin - Abstract:
- Abstract: Background: Severe mitral regurgitation (MR) is associated with progressive heart failure and impairment of survival. Degenerative MR accounts for most MV repair surgeries. Conventional mitral valve repair surgery requires cardiopulmonary bypass and is associated with significant morbidity and risks. Transapical beating‐heart mitral valve repair by artificial chordae implantation with transesophageal echocardiography (TEE) guidance has the potential to significantly reduce surgical morbidity. We report the first‐in‐human experience of degenerative MR repair using a novel artificial chordae implantation device (Mitralstitch TM system). Methods: Ten patients with severe MR underwent transapical artificial chordae implantation using MitralstitchTM system. The procedure was performed through a small left thoracotomy under general anesthesia and TEE guidance. Patients underwent transthoracic echocardiography and other assessments during the follow‐up. Results: All 10 patients with an average age of 63.7 ± 9.6 years successfully received transapical artificial chordae implantation. Their MR reduced from severe to none or trace in five patients, mild in five patients before discharge. Five patients received one artificial chordal implantation, four patients received two, and one patient received three and edge‐to‐edge repair by locking two of them. The safety and efficacy endpoint were achieved in all patients at 1‐month follow‐up. At 1‐year follow‐up, six patients hadAbstract: Background: Severe mitral regurgitation (MR) is associated with progressive heart failure and impairment of survival. Degenerative MR accounts for most MV repair surgeries. Conventional mitral valve repair surgery requires cardiopulmonary bypass and is associated with significant morbidity and risks. Transapical beating‐heart mitral valve repair by artificial chordae implantation with transesophageal echocardiography (TEE) guidance has the potential to significantly reduce surgical morbidity. We report the first‐in‐human experience of degenerative MR repair using a novel artificial chordae implantation device (Mitralstitch TM system). Methods: Ten patients with severe MR underwent transapical artificial chordae implantation using MitralstitchTM system. The procedure was performed through a small left thoracotomy under general anesthesia and TEE guidance. Patients underwent transthoracic echocardiography and other assessments during the follow‐up. Results: All 10 patients with an average age of 63.7 ± 9.6 years successfully received transapical artificial chordae implantation. Their MR reduced from severe to none or trace in five patients, mild in five patients before discharge. Five patients received one artificial chordal implantation, four patients received two, and one patient received three and edge‐to‐edge repair by locking two of them. The safety and efficacy endpoint were achieved in all patients at 1‐month follow‐up. At 1‐year follow‐up, six patients had mild MR, three patients had moderate MR, one patient had recurrence of severe MR and underwent surgical repair. Conclusions: The results of this first‐in‐human study show safety and feasibility of transapical mitral valve repair using MitralStitch system. Patient selection and technical refinement are crucial to improve the outcomes. … (more)
- Is Part Of:
- Journal of cardiac surgery. Volume 37:Issue 5(2022)
- Journal:
- Journal of cardiac surgery
- Issue:
- Volume 37:Issue 5(2022)
- Issue Display:
- Volume 37, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 37
- Issue:
- 5
- Issue Sort Value:
- 2022-0037-0005-0000
- Page Start:
- 1242
- Page End:
- 1249
- Publication Date:
- 2022-02-26
- Subjects:
- artifial chordae -- mitrial regurgitation -- transapical
Heart -- Surgery -- Periodicals
617.412005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8191 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=jcs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/jocs.16342 ↗
- Languages:
- English
- ISSNs:
- 0886-0440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.863500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27087.xml