Wavefront-guided PRK treatment of myopia using a refractive aberrometer. Issue 3 (March 2023)
- Record Type:
- Journal Article
- Title:
- Wavefront-guided PRK treatment of myopia using a refractive aberrometer. Issue 3 (March 2023)
- Main Title:
- Wavefront-guided PRK treatment of myopia using a refractive aberrometer
- Authors:
- Hofmeister, Elizabeth M.
Cason, John B.
Murdoch, Donna M.
Yau, Irene W.
Wang, Ying
Parizadeh, Dari D.
Janakiraman, Devi Priya
Kasthurirangan, Sanjeev - Abstract:
- Abstract : A prospective multicentered wavefront-guided PRK clinical study using an aberrometer that incorporated a Hartmann-Shack wavefront sensor demonstrated good predictability and visual outcomes, and favorable patient-reported outcomes for the correction of myopia. Abstract : Purpose: To evaluate the safety, effectiveness, and patient-reported outcomes of wavefront-guided photorefractive keratectomy (PRK) for the correction of myopic refractive errors with and without astigmatism. Setting: U.S. multicenter study. Design: Prospective, nonrandomized clinical investigation. Methods: 334 eyes (167 patients) underwent wavefront-guided PRK with the STAR S4 IR Excimer Laser System. Patients had preoperative myopic refractive errors with sphere up to −8.00 diopters (D) and cylinder up to −4.00 D with a maximum spherical equivalent (SE) of −10.00 D. All eyes were targeted for emmetropia, and treatment plans were derived from the iDESIGN system wavefront measurements. Results: At 6 months, the point of refractive stability, 99.4% of eyes achieved 20/20 or better uncorrected distance visual acuity (UDVA), 92% of eyes achieved 20/16 or better UDVA, 85.5% of eyes achieved manifest refraction SE (MRSE) within 0.50 D of target, mean SE was −0.06, and less than 1% of eyes lost more than 2 lines of corrected distance visual acuity. Glare and halos occurred with similar or lower frequencies at 6 months vs preoperative. Results from the National Eye Institute Refractive Error Quality ofAbstract : A prospective multicentered wavefront-guided PRK clinical study using an aberrometer that incorporated a Hartmann-Shack wavefront sensor demonstrated good predictability and visual outcomes, and favorable patient-reported outcomes for the correction of myopia. Abstract : Purpose: To evaluate the safety, effectiveness, and patient-reported outcomes of wavefront-guided photorefractive keratectomy (PRK) for the correction of myopic refractive errors with and without astigmatism. Setting: U.S. multicenter study. Design: Prospective, nonrandomized clinical investigation. Methods: 334 eyes (167 patients) underwent wavefront-guided PRK with the STAR S4 IR Excimer Laser System. Patients had preoperative myopic refractive errors with sphere up to −8.00 diopters (D) and cylinder up to −4.00 D with a maximum spherical equivalent (SE) of −10.00 D. All eyes were targeted for emmetropia, and treatment plans were derived from the iDESIGN system wavefront measurements. Results: At 6 months, the point of refractive stability, 99.4% of eyes achieved 20/20 or better uncorrected distance visual acuity (UDVA), 92% of eyes achieved 20/16 or better UDVA, 85.5% of eyes achieved manifest refraction SE (MRSE) within 0.50 D of target, mean SE was −0.06, and less than 1% of eyes lost more than 2 lines of corrected distance visual acuity. Glare and halos occurred with similar or lower frequencies at 6 months vs preoperative. Results from the National Eye Institute Refractive Error Quality of life questionnaire showed statistically significant improvements at 6 months vs preoperative across most measures of vision-related functioning and well-being. Approximately 98% of patients reported high satisfaction with their overall vision at 6 months. Conclusions: Wavefront-guided PRK with the iDESIGN aberrometer was safe, effective, and predictable for the correction of low to moderate myopia with and without astigmatism and led to high patient satisfaction. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 49:Issue 3(2023)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 49:Issue 3(2023)
- Issue Display:
- Volume 49, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 49
- Issue:
- 3
- Issue Sort Value:
- 2023-0049-0003-0000
- Page Start:
- 292
- Page End:
- 298
- Publication Date:
- 2023-03
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000001083 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27107.xml