Standard vs total keratometry for intraocular lens power calculation in cataract surgery combined with DMEK. Issue 3 (March 2023)
- Record Type:
- Journal Article
- Title:
- Standard vs total keratometry for intraocular lens power calculation in cataract surgery combined with DMEK. Issue 3 (March 2023)
- Main Title:
- Standard vs total keratometry for intraocular lens power calculation in cataract surgery combined with DMEK
- Authors:
- Khan, Asher
Rangu, Neal
Murphy, David A.
Cooke, David L.
Siatkowski, Rhea L.
Mittal, Aman
Wendelstein, Jascha A.
Riaz, Kamran M. - Abstract:
- Abstract : The prediction accuracy of standard keratometry for IOL calculation was higher than that of total keratometry in eyes that underwent cataract surgery combined with DMEK. Abstract : Purpose: To compare the prediction accuracy of standard keratometry (K) and total keratometry (TK) for intraocular lens (IOL) power calculation in eyes undergoing combined cataract surgery and Descemet membrane endothelial keratoplasty (triple DMEK). Setting: Tertiary care academic referral center. Design: Retrospective case series. Methods: Review of 83 eyes (63 patients) that underwent triple DMEK between 2019 and 2021. Biometry measurements were obtained using a swept-source optical biometer (IOLMaster 700). 63 eyes were used for statistical analysis. Mean error, mean absolute error (MAE), SD, median absolute error, maximum absolute error, root mean squared prediction error, and the percentage of eyes within prediction errors of ±0.50 diopters (D) and ±1.00 D were calculated for 9 multivariate and third-generation formulas using K and TK values (Barrett Universal II, Yeo EVO 2.0, Cooke K6, Kane, Pearl-DGS, Haigis, Holladay 1, Hoffer Q, and SRK/T). Formulas were additionally tested by using the prediction for an IOL power 1 D below the IOL used (IOLup1D). Results: For all formulas, MAE was lower for K than for TK by an average of 0.21 D. The lowest MAE value observed was 0.67 D for "adjusted" SRK/T using K, and the highest MAE values observed were 1.24 D and 1.24 D for nonadjustedAbstract : The prediction accuracy of standard keratometry for IOL calculation was higher than that of total keratometry in eyes that underwent cataract surgery combined with DMEK. Abstract : Purpose: To compare the prediction accuracy of standard keratometry (K) and total keratometry (TK) for intraocular lens (IOL) power calculation in eyes undergoing combined cataract surgery and Descemet membrane endothelial keratoplasty (triple DMEK). Setting: Tertiary care academic referral center. Design: Retrospective case series. Methods: Review of 83 eyes (63 patients) that underwent triple DMEK between 2019 and 2021. Biometry measurements were obtained using a swept-source optical biometer (IOLMaster 700). 63 eyes were used for statistical analysis. Mean error, mean absolute error (MAE), SD, median absolute error, maximum absolute error, root mean squared prediction error, and the percentage of eyes within prediction errors of ±0.50 diopters (D) and ±1.00 D were calculated for 9 multivariate and third-generation formulas using K and TK values (Barrett Universal II, Yeo EVO 2.0, Cooke K6, Kane, Pearl-DGS, Haigis, Holladay 1, Hoffer Q, and SRK/T). Formulas were additionally tested by using the prediction for an IOL power 1 D below the IOL used (IOLup1D). Results: For all formulas, MAE was lower for K than for TK by an average of 0.21 D. The lowest MAE value observed was 0.67 D for "adjusted" SRK/T using K, and the highest MAE values observed were 1.24 D and 1.24 D for nonadjusted Hoffer Q and Haigis using TK, respectively. Overall, lower MAE values were observed for multivariate formulas and SRK/T. Conclusions: In triple DMEK eyes, the prediction accuracy of K was higher than that of TK. The most accurate formulas were SRK/T and multivariate formulas using K with the IOLup1D adjustment. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 49:Issue 3(2023)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 49:Issue 3(2023)
- Issue Display:
- Volume 49, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 49
- Issue:
- 3
- Issue Sort Value:
- 2023-0049-0003-0000
- Page Start:
- 239
- Page End:
- 245
- Publication Date:
- 2023-03
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000001106 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27107.xml