Accuracy and concordance of two-dimensional shear-wave elastography using transient elastography as the reference in chronic viral hepatitis and HIV infection in Rio de Janeiro, Brazil. Issue 5 (18th May 2023)
- Record Type:
- Journal Article
- Title:
- Accuracy and concordance of two-dimensional shear-wave elastography using transient elastography as the reference in chronic viral hepatitis and HIV infection in Rio de Janeiro, Brazil. Issue 5 (18th May 2023)
- Main Title:
- Accuracy and concordance of two-dimensional shear-wave elastography using transient elastography as the reference in chronic viral hepatitis and HIV infection in Rio de Janeiro, Brazil
- Authors:
- Coelho, Mariana
Fernandes, Flavia
Cardoso, Sandra W.
Piedade, Juliana
Torres da Silva, Marcos Vinícius
Santos, Ricardo
Veloso, Valdilea G.
Grinsztejn, Beatriz
Pereira, Gustavo Henrique
Perazzo, Hugo - Abstract:
- Abstract : Objectives: Evaluate the accuracy and agreement of two-dimensional shear-wave elastography (2D-SWE) LOGIQ-S8 with transient elastography in patients from Rio de Janeiro, Brazil. Method: This retrospective study compared liver stiffness measurements (LSMs) using transient elastography (M and XL probes) and 2D-SWE GE-LOGIQ-S8 performed by a single experienced operator on the same day in 348 consecutive individuals with viral hepatitis or HIV infection. Suggestive and highly suggestive compensated-advanced chronic liver disease (c-ACLD) were defined by transient elastography-LSM ≥10 kPa and ≥15 kPa, respectively. Agreement between techniques and accuracy of 2D-SWE using transient elastography-M probe as the reference was assessed. Optimal cut-offs for 2D-SWE were identified using the maximal Youden index. Results: Three hundred five patients [61.3% male, median age = 51 [interquartile range (IQR), 42–62] years, 24% with hepatitis C virus (HCV) ± HIV; 17% with hepatitis B virus (HBV) ± HIV; 31% were HIV mono-infected and 28% had HCV ± HIV post-sustained virological response] were included. The overall correlation (Spearman's ρ ) was moderate between 2D-SWE and transient elastography-M ( ρ = 0.639) and weak between 2D-SWE and transient elastography-XL ( ρ = 0.566). Agreements were strong ( ρ > 0.800) in people with HCV or HBV mono-infection, and poor in HIV mono-infected ( ρ > 0.400). Accuracy of 2D-SWE for transient elastography-M ≥ 10 kPa [area under the receiverAbstract : Objectives: Evaluate the accuracy and agreement of two-dimensional shear-wave elastography (2D-SWE) LOGIQ-S8 with transient elastography in patients from Rio de Janeiro, Brazil. Method: This retrospective study compared liver stiffness measurements (LSMs) using transient elastography (M and XL probes) and 2D-SWE GE-LOGIQ-S8 performed by a single experienced operator on the same day in 348 consecutive individuals with viral hepatitis or HIV infection. Suggestive and highly suggestive compensated-advanced chronic liver disease (c-ACLD) were defined by transient elastography-LSM ≥10 kPa and ≥15 kPa, respectively. Agreement between techniques and accuracy of 2D-SWE using transient elastography-M probe as the reference was assessed. Optimal cut-offs for 2D-SWE were identified using the maximal Youden index. Results: Three hundred five patients [61.3% male, median age = 51 [interquartile range (IQR), 42–62] years, 24% with hepatitis C virus (HCV) ± HIV; 17% with hepatitis B virus (HBV) ± HIV; 31% were HIV mono-infected and 28% had HCV ± HIV post-sustained virological response] were included. The overall correlation (Spearman's ρ ) was moderate between 2D-SWE and transient elastography-M ( ρ = 0.639) and weak between 2D-SWE and transient elastography-XL ( ρ = 0.566). Agreements were strong ( ρ > 0.800) in people with HCV or HBV mono-infection, and poor in HIV mono-infected ( ρ > 0.400). Accuracy of 2D-SWE for transient elastography-M ≥ 10 kPa [area under the receiver operating characteristic (AUROC) = 0.91 (95% confidence interval [CI], 0.86–0.96); optimal cut-off = 6.4 kPa, sensitivity = 84% (95% CI, 72–92), specificity = 89% (95% CI, 84–92)] and for transient elastography-M ≥ 15 kPa [AUROC = 0.93 (95% CI, 0.88–0.98); optimal cut-off = 7.1 kPa; sensitivity = 91% (95% CI, 75–98), specificity = 89% (95% CI, 85–93)] were excellent. Conclusion: 2D-SWE LOGIQ-S8 system had a good agreement with transient elastography and an excellent accuracy to identify individuals at high risk for c-ACLD. … (more)
- Is Part Of:
- European journal of gastroenterology & hepatology. Volume 35:Issue 5(2023)
- Journal:
- European journal of gastroenterology & hepatology
- Issue:
- Volume 35:Issue 5(2023)
- Issue Display:
- Volume 35, Issue 5 (2023)
- Year:
- 2023
- Volume:
- 35
- Issue:
- 5
- Issue Sort Value:
- 2023-0035-0005-0000
- Page Start:
- 583
- Page End:
- 590
- Publication Date:
- 2023-05-18
- Subjects:
- chronic viral hepatitis -- HIV infection -- liver elastography -- shear-wave
Digestive organs -- Diseases -- Periodicals
Liver -- Diseases -- Periodicals
Digestive organs -- Diseases
Liver -- Diseases
Periodicals
616.33 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00042737-000000000-00000 ↗
http://www.eurojgh.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/MEG.0000000000002537 ↗
- Languages:
- English
- ISSNs:
- 0954-691X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.729400
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 27082.xml