Positive and Neutral Needleless Connectors: A Comparative Study of Central-line Associated Bloodstream Infection, Occlusion, and Bacterial Contamination of the Connector Lumen. Issue 3 (May 2023)
- Record Type:
- Journal Article
- Title:
- Positive and Neutral Needleless Connectors: A Comparative Study of Central-line Associated Bloodstream Infection, Occlusion, and Bacterial Contamination of the Connector Lumen. Issue 3 (May 2023)
- Main Title:
- Positive and Neutral Needleless Connectors: A Comparative Study of Central-line Associated Bloodstream Infection, Occlusion, and Bacterial Contamination of the Connector Lumen
- Authors:
- Schora, Donna
Patel, Parul
Barza, Ruby
Patel, Jignesh
Wilson, Kathleen
Espina-Gabriel, Paulette
Nunez, Vesna
Singh, Kamaljit - Abstract:
- Abstract : A pragmatic, multiphase prospective quality improvement initiative was performed to determine whether a positive displacement connector (PD) causes reduction of central line-associated bloodstream infection (CLABSI), occlusion, and catheter hub colonization when compared with a neutral displacement connector with alcohol disinfecting cap (AC). Patients with an active central vascular access device (CVAD) were enrolled March 2018 to February 2019 (P2) and compared to the prior year (P1). Two hospitals were randomized to use PD without AC (Hospital A) and with AC (Hospital B). Two hospitals utilized a neutral displacement connector with AC (Hospitals C and D). CVADs were monitored for CLABSI, occlusion, and bacterial contamination during P2. Of the 2454 lines in the study, 1049 were cultured. CLABSI decreased in all groups between P1 and P2: Hospital A, 13 (1.1%) to 2 (0.2%); Hospital B, 2 (0.3%) to 0; and Hospitals C and D, 5 (0.5%) to 1 (0.1%). CLABSI reduction was equivalent between P1 and P2 with and without AC, at around 86%. The rate of occlusion per lumen was 14.4%, 12.1%, and 8.5% for Hospitals A, B and C, D, respectively. Hospitals using PD had a higher rate of occlusion than those that did not ( P = .003). Lumen contamination with pathogens was 1.5% for Hospitals A and B and 2.1% for Hospitals C and D ( P = .38). The rate of CLABSI was reduced with both connectors, and PD reduced infections with and without the use of AC. Both connector types had low-levelAbstract : A pragmatic, multiphase prospective quality improvement initiative was performed to determine whether a positive displacement connector (PD) causes reduction of central line-associated bloodstream infection (CLABSI), occlusion, and catheter hub colonization when compared with a neutral displacement connector with alcohol disinfecting cap (AC). Patients with an active central vascular access device (CVAD) were enrolled March 2018 to February 2019 (P2) and compared to the prior year (P1). Two hospitals were randomized to use PD without AC (Hospital A) and with AC (Hospital B). Two hospitals utilized a neutral displacement connector with AC (Hospitals C and D). CVADs were monitored for CLABSI, occlusion, and bacterial contamination during P2. Of the 2454 lines in the study, 1049 were cultured. CLABSI decreased in all groups between P1 and P2: Hospital A, 13 (1.1%) to 2 (0.2%); Hospital B, 2 (0.3%) to 0; and Hospitals C and D, 5 (0.5%) to 1 (0.1%). CLABSI reduction was equivalent between P1 and P2 with and without AC, at around 86%. The rate of occlusion per lumen was 14.4%, 12.1%, and 8.5% for Hospitals A, B and C, D, respectively. Hospitals using PD had a higher rate of occlusion than those that did not ( P = .003). Lumen contamination with pathogens was 1.5% for Hospitals A and B and 2.1% for Hospitals C and D ( P = .38). The rate of CLABSI was reduced with both connectors, and PD reduced infections with and without the use of AC. Both connector types had low-level catheter hub colonization with significant bacteria. The lowest rates of occlusion were found in the group using neutral displacement connectors. … (more)
- Is Part Of:
- Journal of infusion nursing. Volume 46:Issue 3(2023)
- Journal:
- Journal of infusion nursing
- Issue:
- Volume 46:Issue 3(2023)
- Issue Display:
- Volume 46, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 46
- Issue:
- 3
- Issue Sort Value:
- 2023-0046-0003-0000
- Page Start:
- 157
- Page End:
- 161
- Publication Date:
- 2023-05
- Subjects:
- CLABSI -- lumen contamination -- needle-free connector -- occlusion
Infusion therapy -- Periodicals
Parenteral therapy -- Periodicals
Intubation -- Periodicals
Intravenous therapy -- Periodicals
Nursing -- Periodicals
615.6 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=N&PAGE=toc&D=ovft&AN=00129804-000000000-00000 ↗
http://journals.lww.com/journalofinfusionnursing/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/NAN.0000000000000506 ↗
- Languages:
- English
- ISSNs:
- 1533-1458
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5006.865000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27069.xml