Venovenous extracorporeal CO2 removal to support ultraprotective ventilation in moderate-severe acute respiratory distress syndrome: A systematic review and meta-analysis of the literature. (July 2023)
- Record Type:
- Journal Article
- Title:
- Venovenous extracorporeal CO2 removal to support ultraprotective ventilation in moderate-severe acute respiratory distress syndrome: A systematic review and meta-analysis of the literature. (July 2023)
- Main Title:
- Venovenous extracorporeal CO2 removal to support ultraprotective ventilation in moderate-severe acute respiratory distress syndrome: A systematic review and meta-analysis of the literature
- Authors:
- Worku, Elliott
Brodie, Daniel
Ling, Ryan Ruiyang
Ramanathan, Kollengode
Combes, Alain
Shekar, Kiran - Abstract:
- Background: A strategy that limits tidal volumes and inspiratory pressures, improves outcomes in patients with the acute respiratory distress syndrome (ARDS). Extracorporeal carbon dioxide removal (ECCO2 R) may facilitate ultra-protective ventilation. We conducted a systematic review and meta-analysis to evaluate the efficacy and safety of venovenous ECCO2 R in supporting ultra-protective ventilation in moderate-to-severe ARDS. Methods: MEDLINE and EMBASE were interrogated for studies (2000–2021) reporting venovenous ECCO2 R use in patients with moderate-to-severe ARDS. Studies reporting ≥10 adult patients in English language journals were included. Ventilatory parameters after 24 h of initiating ECCO2 R, device characteristics, and safety outcomes were collected. The primary outcome measure was the change in driving pressure at 24 h of ECCO2 R therapy in relation to baseline. Secondary outcomes included change in tidal volume, gas exchange, and safety data. Results: Ten studies reporting 421 patients (PaO2 :FiO2 141.03 mmHg) were included. Extracorporeal blood flow rates ranged from 0.35-1.5 L/min. Random effects modelling indicated a 3.56 cmH2 O reduction (95%-CI: 3.22–3.91) in driving pressure from baseline ( p < .001) and a 1.89 mL/kg (95%-CI: 1.75–2.02, p < .001) reduction in tidal volume. Oxygenation, respiratory rate and PEEP remained unchanged. No significant interactions between driving pressure reduction and baseline driving pressure, partial pressure of arterialBackground: A strategy that limits tidal volumes and inspiratory pressures, improves outcomes in patients with the acute respiratory distress syndrome (ARDS). Extracorporeal carbon dioxide removal (ECCO2 R) may facilitate ultra-protective ventilation. We conducted a systematic review and meta-analysis to evaluate the efficacy and safety of venovenous ECCO2 R in supporting ultra-protective ventilation in moderate-to-severe ARDS. Methods: MEDLINE and EMBASE were interrogated for studies (2000–2021) reporting venovenous ECCO2 R use in patients with moderate-to-severe ARDS. Studies reporting ≥10 adult patients in English language journals were included. Ventilatory parameters after 24 h of initiating ECCO2 R, device characteristics, and safety outcomes were collected. The primary outcome measure was the change in driving pressure at 24 h of ECCO2 R therapy in relation to baseline. Secondary outcomes included change in tidal volume, gas exchange, and safety data. Results: Ten studies reporting 421 patients (PaO2 :FiO2 141.03 mmHg) were included. Extracorporeal blood flow rates ranged from 0.35-1.5 L/min. Random effects modelling indicated a 3.56 cmH2 O reduction (95%-CI: 3.22–3.91) in driving pressure from baseline ( p < .001) and a 1.89 mL/kg (95%-CI: 1.75–2.02, p < .001) reduction in tidal volume. Oxygenation, respiratory rate and PEEP remained unchanged. No significant interactions between driving pressure reduction and baseline driving pressure, partial pressure of arterial carbon dioxide or PaO2 :FiO2 ratio were identified in metaregression analysis. Bleeding and haemolysis were the commonest complications of therapy. Conclusions: Venovenous ECCO2 R permitted significant reductions in ∆P in patients with moderate-to-severe ARDS. Heterogeneity amongst studies and devices, a paucity of randomised controlled trials, and variable safety reporting calls for standardisation of outcome reporting. Prospective evaluation of optimal device operation and anticoagulation in high quality studies is required before further recommendations can be made. … (more)
- Is Part Of:
- Perfusion. Volume 38:Number 5(2023)
- Journal:
- Perfusion
- Issue:
- Volume 38:Number 5(2023)
- Issue Display:
- Volume 38, Issue 5 (2023)
- Year:
- 2023
- Volume:
- 38
- Issue:
- 5
- Issue Sort Value:
- 2023-0038-0005-0000
- Page Start:
- 1062
- Page End:
- 1079
- Publication Date:
- 2023-07
- Subjects:
- Acute respiratory distress syndrome -- extracorporeal carbon dioxide removal -- extracorporeal membrane oxygenation -- ultra-protective lung ventilation -- ventilator-induced lung injury -- driving pressure
Perfusion (Physiology) -- Periodicals
Blood -- Circulation, Artificial -- Periodicals
Heart -- Surgery -- Periodicals
Extracorporeal Circulation -- Periodicals
Perfusion -- Periodicals
Circulation extracorporelle -- Périodiques
Perfusion -- Périodiques
617.41 - Journal URLs:
- http://prf.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/02676591221096225 ↗
- Languages:
- English
- ISSNs:
- 0267-6591
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27078.xml