Effect of aortic cannulation depth on air emboli transport during cardiopulmonary bypass: A computational study. (July 2023)
- Record Type:
- Journal Article
- Title:
- Effect of aortic cannulation depth on air emboli transport during cardiopulmonary bypass: A computational study. (July 2023)
- Main Title:
- Effect of aortic cannulation depth on air emboli transport during cardiopulmonary bypass: A computational study
- Authors:
- Ho, Raymond
McDonald, Charles
Pauls, Jo P
Li, Zhiyong - Abstract:
- Introduction: Varying the insertion depth of the aortic cannula during cardiopulmonary bypass (CPB) has been investigated as a strategy to mitigate cerebral emboli, yet its effectiveness associated with CPB flow is not fully understood. We compared different arterial cannula insertion depths and pump flow influencing air microemboli entering the aortic arch branch arteries (AABA). Methods: A computational approach used a patient-specific aorta model to evaluate four cannula locations at (1) proximal arch, (2) mid arch, (3) distal arch, and (4) descending aorta. We injected 0.1 mm microemboli (N=720) at 2 and 5 L/min and assessed the embolic load and the particle averaged transit times ( entering the AABA. Results: Location 4 had the lowest embolic load (2 L/min: N= 63) and (5 L/min: N= 54) compared to locations 1 to 3 in the range of (N= 118 to 116 at 2 L/min:) and (N= 92 to 146 at 5 L/min). There was no significant difference between 2 L/min and 5 L/min (p = 0.31), despite 5 L/min attaining a lower mean (±standard deviation) than 2 L/min (38.0±23.4 vs 44.5±21.1), respectively. Progressing from location 1 to 4, increased 3.11s -7.40 s at 2 L/min and 1.81s -4.18s at 5 L/min. Conclusion: It was demonstrated that the elongated cannula insertion length resulted in lower embolic loads, particularly at a higher flow rate. The numerical results suggest that CPB management could combine active flow variation with improving cannula performance and provide a foundation for a futureIntroduction: Varying the insertion depth of the aortic cannula during cardiopulmonary bypass (CPB) has been investigated as a strategy to mitigate cerebral emboli, yet its effectiveness associated with CPB flow is not fully understood. We compared different arterial cannula insertion depths and pump flow influencing air microemboli entering the aortic arch branch arteries (AABA). Methods: A computational approach used a patient-specific aorta model to evaluate four cannula locations at (1) proximal arch, (2) mid arch, (3) distal arch, and (4) descending aorta. We injected 0.1 mm microemboli (N=720) at 2 and 5 L/min and assessed the embolic load and the particle averaged transit times ( entering the AABA. Results: Location 4 had the lowest embolic load (2 L/min: N= 63) and (5 L/min: N= 54) compared to locations 1 to 3 in the range of (N= 118 to 116 at 2 L/min:) and (N= 92 to 146 at 5 L/min). There was no significant difference between 2 L/min and 5 L/min (p = 0.31), despite 5 L/min attaining a lower mean (±standard deviation) than 2 L/min (38.0±23.4 vs 44.5±21.1), respectively. Progressing from location 1 to 4, increased 3.11s -7.40 s at 2 L/min and 1.81s -4.18s at 5 L/min. Conclusion: It was demonstrated that the elongated cannula insertion length resulted in lower embolic loads, particularly at a higher flow rate. The numerical results suggest that CPB management could combine active flow variation with improving cannula performance and provide a foundation for a future experimental and clinical investigation to reduce surgical cerebral air microemboli. … (more)
- Is Part Of:
- Perfusion. Volume 38:Number 5(2023)
- Journal:
- Perfusion
- Issue:
- Volume 38:Number 5(2023)
- Issue Display:
- Volume 38, Issue 5 (2023)
- Year:
- 2023
- Volume:
- 38
- Issue:
- 5
- Issue Sort Value:
- 2023-0038-0005-0000
- Page Start:
- 993
- Page End:
- 1001
- Publication Date:
- 2023-07
- Subjects:
- cannula -- cardiopulmonary bypass -- gaseous microemboli -- pump flow
Perfusion (Physiology) -- Periodicals
Blood -- Circulation, Artificial -- Periodicals
Heart -- Surgery -- Periodicals
Extracorporeal Circulation -- Periodicals
Perfusion -- Periodicals
Circulation extracorporelle -- Périodiques
Perfusion -- Périodiques
617.41 - Journal URLs:
- http://prf.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/02676591221092942 ↗
- Languages:
- English
- ISSNs:
- 0267-6591
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27077.xml