Stability and performance of the EnSite Precision cardiac mapping system for electrophysiology mapping and ablation procedures: results from the EnSite Precision observational study. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Stability and performance of the EnSite Precision cardiac mapping system for electrophysiology mapping and ablation procedures: results from the EnSite Precision observational study. (25th November 2020)
- Main Title:
- Stability and performance of the EnSite Precision cardiac mapping system for electrophysiology mapping and ablation procedures: results from the EnSite Precision observational study
- Authors:
- Lin, D
Glover, B
Colley, J
Thibault, B
Steinberg, C.M
Jewell, C
Bernard, M
Siddiqui, U
Li, J
Sarver, A
Hsu, J
Cooper, D - Abstract:
- Abstract: Background: The EnSite Precision™ Cardiac Mapping System is a catheter navigation and mapping system capable of displaying the three-dimensional (3D) position of conventional and sensor enabled electrophysiology catheters, as well as displaying cardiac electrical activity as waveform traces and dynamic 3-D maps of cardiac chambers. Objective: The EnSite Precision™ Observational Study was designed to quantify and characterize the use of the EnSite Precision™ Cardiac Mapping System for mapping and ablation of cardiac arrhythmias in a real-world environment and to evaluate procedural and subsequent clinical outcomes. Methods: 1065 patients were enrolled at 38 centers in the U.S. and Canada between 2017–2018. Eligible subjects were adults undergoing a cardiac electrophysiology mapping and radiofrequency ablation procedures using the EnSite Precision™ System. Results: Of 989 patients who completed the protocol, a geometry was created in 936 (94.7%). Most initial maps were created using Automap (n=545, 67.0%) or a combination of Automap and manually mapping (n=151, 18.6%). Median time to create an initial map was 9.0 min (IQR 5.0–15.0), with a median number of used mapping points per minute of 92.7 (IQR 30.0–192.0). During ablation, AutoMark was used in 817 (82.6%) of procedures. The most frequent metrics for lesion color were Impedance Drop or Impedance Drop Percent (45.5% combined), time (23.9%) and average force (14.2%). At Canadian sites where LSI was an option, itAbstract: Background: The EnSite Precision™ Cardiac Mapping System is a catheter navigation and mapping system capable of displaying the three-dimensional (3D) position of conventional and sensor enabled electrophysiology catheters, as well as displaying cardiac electrical activity as waveform traces and dynamic 3-D maps of cardiac chambers. Objective: The EnSite Precision™ Observational Study was designed to quantify and characterize the use of the EnSite Precision™ Cardiac Mapping System for mapping and ablation of cardiac arrhythmias in a real-world environment and to evaluate procedural and subsequent clinical outcomes. Methods: 1065 patients were enrolled at 38 centers in the U.S. and Canada between 2017–2018. Eligible subjects were adults undergoing a cardiac electrophysiology mapping and radiofrequency ablation procedures using the EnSite Precision™ System. Results: Of 989 patients who completed the protocol, a geometry was created in 936 (94.7%). Most initial maps were created using Automap (n=545, 67.0%) or a combination of Automap and manually mapping (n=151, 18.6%). Median time to create an initial map was 9.0 min (IQR 5.0–15.0), with a median number of used mapping points per minute of 92.7 (IQR 30.0–192.0). During ablation, AutoMark was used in 817 (82.6%) of procedures. The most frequent metrics for lesion color were Impedance Drop or Impedance Drop Percent (45.5% combined), time (23.9%) and average force (14.2%). At Canadian sites where LSI was an option, it was used as the color metric in 87 (45.8%) of cases (10.6% overall). The EnSite System was stable throughout 79.7% (n=788 of 989) of procedures. Factors affecting stability were respiratory change (n=88 of 989, 8.9%), patient movement (n=73, 7.4%), CS Positional Reference dislodgement (n=32, 3.2%), and cardioversion (n=19, 1.9%). Conscious sedation was used in 189 (19.1%) of patients. Acute success was reached based on the pre-defined endpoints for the procedure in 97.4% (n=963) of cases. Conclusion: In a real-world study analysis, the EnSite Precision™ mapping system was associated with a high prevalence of acute procedural success, low mapping times, and high system stability. Funding Acknowledgement: Type of funding source: None … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Rhythm Control, Catheter Ablation
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.0610 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27044.xml