Fe and C additions decrease the dissolution rate of silicon nitride coatings and are compatible with microglial viability in 3D collagen hydrogels. (15th March 2023)
- Record Type:
- Journal Article
- Title:
- Fe and C additions decrease the dissolution rate of silicon nitride coatings and are compatible with microglial viability in 3D collagen hydrogels. (15th March 2023)
- Main Title:
- Fe and C additions decrease the dissolution rate of silicon nitride coatings and are compatible with microglial viability in 3D collagen hydrogels
- Authors:
- Echeverri, Estefanía
Skjöldebrand, Charlotte
O'Callaghan, Paul
Palmquist, Anders
Kreuger, Johan
Hulsart-Billström, Gry
Persson, Cecilia - Abstract:
- Abstract : The possibility of decreasing the dissolution rate of SiN coatings using Fe and C is promising and the released ions were demonstrated to be compatible with microglia viability, in both 2D cultures and 3D collagen hydrogels. Abstract : Silicon nitride (SiN) coatings may reduce unwanted release of metal ions from metallic implants. However, as SiN slowly dissolves in aqueous solutions, additives that reduce this dissolution rate would likely increase the lifetime and functionality of implants. Adding iron (Fe) and carbon (C) permits tuning of the SiN coatings' mechanical properties, but their effect on SiN dissolution rates, and their capacity to reduce metal ion release from metallic implant substrates, have yet to be investigated. Such coatings have recently been proposed for use in spinal implants; therefore, it is relevant to assess their impact on the viability of cells expected at the implant site, such as microglia, the resident macrophages of the central nervous system (CNS). To study the effects of Fe and C on the dissolution rate of SiN coatings, compositional gradients of Si, Fe and C in combination with N were generated by physical vapor deposition onto CoCrMo discs. Differences in composition did not affect the surface roughness or the release of Si, Fe or Co ions (the latter from the CoCrMo substrate). Adding Fe and C reduced ion release compared to a SiN reference coating, which was attributed to altered reactivity due to an increase in the fractionAbstract : The possibility of decreasing the dissolution rate of SiN coatings using Fe and C is promising and the released ions were demonstrated to be compatible with microglia viability, in both 2D cultures and 3D collagen hydrogels. Abstract : Silicon nitride (SiN) coatings may reduce unwanted release of metal ions from metallic implants. However, as SiN slowly dissolves in aqueous solutions, additives that reduce this dissolution rate would likely increase the lifetime and functionality of implants. Adding iron (Fe) and carbon (C) permits tuning of the SiN coatings' mechanical properties, but their effect on SiN dissolution rates, and their capacity to reduce metal ion release from metallic implant substrates, have yet to be investigated. Such coatings have recently been proposed for use in spinal implants; therefore, it is relevant to assess their impact on the viability of cells expected at the implant site, such as microglia, the resident macrophages of the central nervous system (CNS). To study the effects of Fe and C on the dissolution rate of SiN coatings, compositional gradients of Si, Fe and C in combination with N were generated by physical vapor deposition onto CoCrMo discs. Differences in composition did not affect the surface roughness or the release of Si, Fe or Co ions (the latter from the CoCrMo substrate). Adding Fe and C reduced ion release compared to a SiN reference coating, which was attributed to altered reactivity due to an increase in the fraction of stabilizing Si–C or Fe–C bonds. Extracts from the SiN coatings containing Fe and C were compatible with microglial viability in 2D cultures and 3D collagen hydrogels, to a similar degree as CoCrMo and SiN coated CoCrMo reference extracts. As Fe and C reduced the dissolution rate of SiN-coatings and did not compromise microglial viability, the capacity of these additives to extend the lifetime and functionality of SiN-coated metallic implants warrants further investigation. … (more)
- Is Part Of:
- Biomaterials science. Volume 11:Number 9(2023)
- Journal:
- Biomaterials science
- Issue:
- Volume 11:Number 9(2023)
- Issue Display:
- Volume 11, Issue 9 (2023)
- Year:
- 2023
- Volume:
- 11
- Issue:
- 9
- Issue Sort Value:
- 2023-0011-0009-0000
- Page Start:
- 3144
- Page End:
- 3158
- Publication Date:
- 2023-03-15
- Subjects:
- Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/bm ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d2bm02074b ↗
- Languages:
- English
- ISSNs:
- 2047-4830
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.724000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 27054.xml