Evaluation of the four-dimensional motion of lung tumors during end-exhalation breath-hold conditions using volumetric cine computed tomography images. (May 2023)
- Record Type:
- Journal Article
- Title:
- Evaluation of the four-dimensional motion of lung tumors during end-exhalation breath-hold conditions using volumetric cine computed tomography images. (May 2023)
- Main Title:
- Evaluation of the four-dimensional motion of lung tumors during end-exhalation breath-hold conditions using volumetric cine computed tomography images
- Authors:
- Kamima, Tatsuya
Iino, Misae
Sakai, Ryohei
Ito, Yasushi
Sakae, Takeji
Moriya, Shunsuke
Tokumasu, Kenji
Yoshioka, Yasuo - Abstract:
- Highlights: Evaluation of lung tumor 4D motion during breath-holding (BH) using cine CT. Some cases showed substantial tumor motion in the posterior directions during BH. Surrogate markers (external marker/diaphragm) did not detect tumor motion. In 18% of cases, tumor motion during BH was larger than that during free breathing. Pretreatment evaluation of the tumor motion during BH using cine CT is recommended. Abstract: Background and purpose: This study was performed to evaluate the four-dimensional motion of lung tumors during end-exhalation (EE) breath-holding (BH) using cine computed tomography (CT) and investigate the correlation between tumor and surrogate marker motions. Materials and methods: This study included 28 patients who underwent stereotactic body radiation therapy at our institution and were capable of 15–20 s of EE BH within a ±1.5-mm gating window with external markers. During EE BH with cine CT, 21 s of continuous data were acquired using 320-row multislice CT. Displacements in the tumor position during EE BH were assessed in the left–right (LR), anterior–posterior (AP), and superior–inferior (SI) directions. Pearson's correlation coefficient (r) between tumor motions during EE BH and diaphragm/external marker motions was also determined. Results: The mean absolute maximum displacements of the tumor position during EE BH were 1.3 (range: 0.2–4.0), 1.9 (range: 0.3–12.0), and 1.3 (range: 0.1–7.2) mm in the LR, AP, and SI directions, respectively. TheHighlights: Evaluation of lung tumor 4D motion during breath-holding (BH) using cine CT. Some cases showed substantial tumor motion in the posterior directions during BH. Surrogate markers (external marker/diaphragm) did not detect tumor motion. In 18% of cases, tumor motion during BH was larger than that during free breathing. Pretreatment evaluation of the tumor motion during BH using cine CT is recommended. Abstract: Background and purpose: This study was performed to evaluate the four-dimensional motion of lung tumors during end-exhalation (EE) breath-holding (BH) using cine computed tomography (CT) and investigate the correlation between tumor and surrogate marker motions. Materials and methods: This study included 28 patients who underwent stereotactic body radiation therapy at our institution and were capable of 15–20 s of EE BH within a ±1.5-mm gating window with external markers. During EE BH with cine CT, 21 s of continuous data were acquired using 320-row multislice CT. Displacements in the tumor position during EE BH were assessed in the left–right (LR), anterior–posterior (AP), and superior–inferior (SI) directions. Pearson's correlation coefficient (r) between tumor motions during EE BH and diaphragm/external marker motions was also determined. Results: The mean absolute maximum displacements of the tumor position during EE BH were 1.3 (range: 0.2–4.0), 1.9 (range: 0.3–12.0), and 1.3 (range: 0.1–7.2) mm in the LR, AP, and SI directions, respectively. The displacement of the tumor position in the AP direction was weakly correlated (|r| < 0.4) with the external marker and diaphragm displacements in many cases (proportions of 50% and 46%, respectively). Conclusion: We found some cases showing substantial displacement in lung tumor positions during EE BH, especially in the AP direction. Because these tumor position displacements did not correlate with surrogate markers and were difficult to detect, we recommend pretreatment evaluation of the four-dimensional motions of tumors during BH using cine CT. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 182(2023)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 182(2023)
- Issue Display:
- Volume 182, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 182
- Issue:
- 2023
- Issue Sort Value:
- 2023-0182-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-05
- Subjects:
- Stereotactic body radiation therapy -- End-exhalation breath-holding -- Volumetric cine CT -- Surrogate marker
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2023.109573 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27045.xml