Development of a validation imaging dataset for Molecular Radiotherapy dosimetry multicenter intercomparison exercises based on anthropomorphic phantoms. (May 2023)
- Record Type:
- Journal Article
- Title:
- Development of a validation imaging dataset for Molecular Radiotherapy dosimetry multicenter intercomparison exercises based on anthropomorphic phantoms. (May 2023)
- Main Title:
- Development of a validation imaging dataset for Molecular Radiotherapy dosimetry multicenter intercomparison exercises based on anthropomorphic phantoms
- Authors:
- Robinson, Andrew P.
Calvert, Nick
Tipping, Jill
Denis-Bacelar, Ana M.
Ferreira, Kelley M.
Lassmann, Michael
Tran-Gia, Johannes - Abstract:
- Abstract: Validation of a Molecular Radiotherapy (MRT) dosimetry system requires imaging data for which an accompanying "ground truth" pharmacokinetic model and absorbed dose calculation are known. Methods: We present a methodology for production of a validation dataset for image based 177 Lu dotatate dosimetry calculations. A pharmacokinetic model is presented with activity concentrations corresponding to common imaging timepoints. Anthropomorphic 3D printed phantoms, corresponding to the organs at risk, have been developed to provide SPECT/CT and Whole Body imaging with known organ activities corresponding to common clinical timepoints. Results: Results for the accuracy of phantom filling reproduce the activity concentrations from the pharmacokinetic model for all timepoints and organs within measurement uncertainties, with a mean deviation of 0.6(8)%. The imaging dataset, ancillary data and phantoms designs are provided as a source of well characterized input data for the validation of clinical MRT dosimetry systems. Conclusions: The combination of pharmacokinetic modelling with the use of anthropomorphic 3D printed phantoms are a promising procedure to provide data for the validation of Molecular Radiotherapy Dosimetry systems, allowing multicentre comparisons. Highlights: An imaging dataset for validation of a Molecular Radiotherapy dosimetry system has been produced. A method for producing a dataset representing a ground truth PK model is presented. PK model reproducedAbstract: Validation of a Molecular Radiotherapy (MRT) dosimetry system requires imaging data for which an accompanying "ground truth" pharmacokinetic model and absorbed dose calculation are known. Methods: We present a methodology for production of a validation dataset for image based 177 Lu dotatate dosimetry calculations. A pharmacokinetic model is presented with activity concentrations corresponding to common imaging timepoints. Anthropomorphic 3D printed phantoms, corresponding to the organs at risk, have been developed to provide SPECT/CT and Whole Body imaging with known organ activities corresponding to common clinical timepoints. Results: Results for the accuracy of phantom filling reproduce the activity concentrations from the pharmacokinetic model for all timepoints and organs within measurement uncertainties, with a mean deviation of 0.6(8)%. The imaging dataset, ancillary data and phantoms designs are provided as a source of well characterized input data for the validation of clinical MRT dosimetry systems. Conclusions: The combination of pharmacokinetic modelling with the use of anthropomorphic 3D printed phantoms are a promising procedure to provide data for the validation of Molecular Radiotherapy Dosimetry systems, allowing multicentre comparisons. Highlights: An imaging dataset for validation of a Molecular Radiotherapy dosimetry system has been produced. A method for producing a dataset representing a ground truth PK model is presented. PK model reproduced all time points and organs within measurement uncertainties. Dataset is available allowing institutions to compare calculated dosimetry values. … (more)
- Is Part Of:
- Physica medica. Volume 109(2023)
- Journal:
- Physica medica
- Issue:
- Volume 109(2023)
- Issue Display:
- Volume 109, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 109
- Issue:
- 2023
- Issue Sort Value:
- 2023-0109-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-05
- Subjects:
- MRT dosimetry -- Phantom -- Lu-177 -- Validation
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2023.102583 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27053.xml