Safety evaluation of the Guardian device on the common carotid artery in sheep. Issue 4 (April 2023)
- Record Type:
- Journal Article
- Title:
- Safety evaluation of the Guardian device on the common carotid artery in sheep. Issue 4 (April 2023)
- Main Title:
- Safety evaluation of the Guardian device on the common carotid artery in sheep
- Authors:
- James, Natalie L.
Milijasevic, Zoran
Ujhazy, Anthony
Huber, David
Rotne, Randi
Edwards, Glenn
Jermyn, Kieri
Celermajer, David S. - Abstract:
- Abstract: Background: Pulse pressure intensity in middle-aged adults is a risk factor for dementia. The Guardian device (The Brain Protection Company, Sydney, Australia) has been developed to reduce pulse pressure, as a potential therapy. Objectives: The aim of this study was to evaluate the safety of the Guardian, a novel pulse modulation device designed to reduce the intensity of the pulse pressure that penetrates into the cerebral small vessels. The Guardian is a helix that gently wraps around the common carotid artery (CCA) to slightly change its shape, to absorb pulsatility, without lowering flow. Methods: The Guardian was implanted bilaterally on the CCAs of 10 mature sheep for chronic implant periods of 3, 6 or 8 months. The ratio of internal device diameter to outer diameter of the CCA varied from 63% to 92% (n = 20). The implant position on the vessel was marked surgically at implant. Gross pathology and histopathology of the CCA were examined at 3- and 6-months post explant. Most devices were explanted using open surgery, however minimally invasive surgical explant techniques were examined in 2 animals to assess the potential of this approach for explant in humans if required. Results: The Guardian was successfully implanted with no adverse events, and minimally invasive explant appeared to be viable for removal. Following implant, the device was surrounded by a thin fibrous capsule, with similar pathology at 3- and 6-months. Minimal or no movement was observed.Abstract: Background: Pulse pressure intensity in middle-aged adults is a risk factor for dementia. The Guardian device (The Brain Protection Company, Sydney, Australia) has been developed to reduce pulse pressure, as a potential therapy. Objectives: The aim of this study was to evaluate the safety of the Guardian, a novel pulse modulation device designed to reduce the intensity of the pulse pressure that penetrates into the cerebral small vessels. The Guardian is a helix that gently wraps around the common carotid artery (CCA) to slightly change its shape, to absorb pulsatility, without lowering flow. Methods: The Guardian was implanted bilaterally on the CCAs of 10 mature sheep for chronic implant periods of 3, 6 or 8 months. The ratio of internal device diameter to outer diameter of the CCA varied from 63% to 92% (n = 20). The implant position on the vessel was marked surgically at implant. Gross pathology and histopathology of the CCA were examined at 3- and 6-months post explant. Most devices were explanted using open surgery, however minimally invasive surgical explant techniques were examined in 2 animals to assess the potential of this approach for explant in humans if required. Results: The Guardian was successfully implanted with no adverse events, and minimally invasive explant appeared to be viable for removal. Following implant, the device was surrounded by a thin fibrous capsule, with similar pathology at 3- and 6-months. Minimal or no movement was observed. CCA sections appeared histologically normal, with no evidence of thrombosis, stenosis, fibrosis, chronic inflammatory response, or vessel degeneration. Conclusions: The feasibility of surgical implantation and biomaterial safety of the Guardian was confirmed over 8 months. Minimally invasive explant of the Guardian has the potential to be viable. Further work is required to demonstrate efficacy in vitro and/or in vivo before evaluation in humans. Highlights: Guardian device biomaterial safety was demonstrated in a sheep model. Guardian devices were implanted bilaterally on common carotid arteries for up to 8 months. Potential for surgical explant via minimally invasive surgery if required. … (more)
- Is Part Of:
- Heliyon. Volume 9:Issue 4(2023)
- Journal:
- Heliyon
- Issue:
- Volume 9:Issue 4(2023)
- Issue Display:
- Volume 9, Issue 4 (2023)
- Year:
- 2023
- Volume:
- 9
- Issue:
- 4
- Issue Sort Value:
- 2023-0009-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-04
- Subjects:
- Common carotid artery -- Pulse pressure wave -- Dementia -- Alzheimer's dementia -- Sheep -- Chronic implant
common carotid artery CCA -- internal diameter i.d. -- outer diameter o.d. -- Charles Sturt University CSU
Research -- Periodicals
Medical sciences -- Periodicals
Natural history -- Periodicals
Social sciences -- Periodicals
Earth sciences -- Periodicals
Physical sciences -- Periodicals
507.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/24058440/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.heliyon.2023.e14909 ↗
- Languages:
- English
- ISSNs:
- 2405-8440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27058.xml