Dosimetric impact of deformable image registration using radiophotoluminescent glass dosimeters with a physical geometric phantom. Issue 4 (7th January 2023)
- Record Type:
- Journal Article
- Title:
- Dosimetric impact of deformable image registration using radiophotoluminescent glass dosimeters with a physical geometric phantom. Issue 4 (7th January 2023)
- Main Title:
- Dosimetric impact of deformable image registration using radiophotoluminescent glass dosimeters with a physical geometric phantom
- Authors:
- Sakulsingharoj, Siwaporn
Kadoya, Noriyuki
Tanaka, Shohei
Sato, Kiyokazu
Nakamura, Mitsuhiro
Jingu, Keiichi - Abstract:
- Abstract: Purpose: To study the dosimetry impact of deformable image registration (DIR) using radiophotoluminescent glass dosimeter (RPLD) and custom developed phantom with various inserts. Methods: The phantom was developed to facilitate simultaneous evaluation of geometric and dosimetric accuracy of DIR. Four computed tomography (CT) images of the phantom were acquired with four different configurations. Four volumetric modulated arc therapy (VMAT) plans were computed for different phantom. Two different patterns were applied to combination of four phantom configurations. RPLD dose measurement was combined between corresponding two phantom configurations. DIR‐based dose accumulation was calculated between corresponding two CT images with two commercial DIR software and various DIR parameter settings, and an open source software. Accumulated dose calculated using DIR was then compared with measured dose using RPLD. Results: The mean ± standard deviation (SD) of dose difference was 2.71 ± 0.23% (range, 2.22%–3.01%) for tumor‐proxy and 3.74 ± 0.79% (range, 1.56%–4.83%) for rectum‐proxy. The mean ± SD of target registration error (TRE) was 1.66 ± 1.36 mm (range, 0.03–4.43 mm) for tumor‐proxy and 6.87 ± 5.49 mm (range, 0.54–17.47 mm) for rectum‐proxy. These results suggested that DIR accuracy had wide range among DIR parameter setting. Conclusions: The dose difference observed in our study was 3% for tumor‐proxy and within 5% for rectum‐proxy. The custom developed physicalAbstract: Purpose: To study the dosimetry impact of deformable image registration (DIR) using radiophotoluminescent glass dosimeter (RPLD) and custom developed phantom with various inserts. Methods: The phantom was developed to facilitate simultaneous evaluation of geometric and dosimetric accuracy of DIR. Four computed tomography (CT) images of the phantom were acquired with four different configurations. Four volumetric modulated arc therapy (VMAT) plans were computed for different phantom. Two different patterns were applied to combination of four phantom configurations. RPLD dose measurement was combined between corresponding two phantom configurations. DIR‐based dose accumulation was calculated between corresponding two CT images with two commercial DIR software and various DIR parameter settings, and an open source software. Accumulated dose calculated using DIR was then compared with measured dose using RPLD. Results: The mean ± standard deviation (SD) of dose difference was 2.71 ± 0.23% (range, 2.22%–3.01%) for tumor‐proxy and 3.74 ± 0.79% (range, 1.56%–4.83%) for rectum‐proxy. The mean ± SD of target registration error (TRE) was 1.66 ± 1.36 mm (range, 0.03–4.43 mm) for tumor‐proxy and 6.87 ± 5.49 mm (range, 0.54–17.47 mm) for rectum‐proxy. These results suggested that DIR accuracy had wide range among DIR parameter setting. Conclusions: The dose difference observed in our study was 3% for tumor‐proxy and within 5% for rectum‐proxy. The custom developed physical phantom with inserts showed potential for accurate evaluation of DIR‐based dose accumulation. The prospect of simultaneous evaluation of geometric and dosimetric DIR accuracy in a single phantom may be useful for validation of DIR for clinical use. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 24:Issue 4(2023)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 24:Issue 4(2023)
- Issue Display:
- Volume 24, Issue 4 (2023)
- Year:
- 2023
- Volume:
- 24
- Issue:
- 4
- Issue Sort Value:
- 2023-0024-0004-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2023-01-07
- Subjects:
- adaptive radiotherapy -- deformable image registration -- dose accumulation -- phantom -- radiotherapy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13890 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27021.xml