Technical note: Low clinical efficacy, but good acceptability of a point‐of‐care electronic palpation device for breast cancer screening for a lower middle‐income environment. Issue 4 (10th February 2022)
- Record Type:
- Journal Article
- Title:
- Technical note: Low clinical efficacy, but good acceptability of a point‐of‐care electronic palpation device for breast cancer screening for a lower middle‐income environment. Issue 4 (10th February 2022)
- Main Title:
- Technical note: Low clinical efficacy, but good acceptability of a point‐of‐care electronic palpation device for breast cancer screening for a lower middle‐income environment
- Authors:
- Valdez, Dustin
Cruz, Teofila
Rania, Stephanie
Badowski, Grazyna
Cassel, Kevin
Wolfgruber, Thomas
Grosskreutz, Scott
Dulana, Louis J.
Adonay, Roy
Maskarinec, Gertraud
Shepherd, John A. - Abstract:
- Abstract: Background: Late‐stage breast cancer rates in the Pacific where mammography services are limited are exceedingly high: Marshall Islands (61%), Palau (94%), and Samoa (79%). Due to the limited medical resources in these areas an alternative accessible technology is needed. The iBreast Exam (iBE) is a point‐of‐care electronic palpitation device that has a reported sensitivity of 86%. However, little is known about the performance and acceptability of this device for women in the Pacific. Methods: A total of 39 women (ages 42–73 years) were recruited in Guam with 19 women having a mammogram requiring biopsy (Breast Imaging‐Reporting and Data System [BI‐RADS] category 4 or above) and 20 women with a negative screening mammogram before the study visit. Participants received an iBE exam and completed a 26‐item breast health questionnaire to evaluate the iBE. Furthermore, the performance characteristics of the iBE were tested using gelatin breast phantoms in terms of tumor size, tumor depth, and overall breast stiffness. Results: The iBE had a sensitivity of 20% (two true positives to eight false negatives) and specificity of 92% (24 false positives to 278 true negatives) when analyzed based on the location of the tumor by quadrant. The iBE also had generally poor agreement according to a Cohen's kappa value of 0.068. The phantom experiments showed that the iBE can detect tumors as deep as 2.5 cm, but only if the lesion is greater than 8 mm in diameter. However, the iBEAbstract: Background: Late‐stage breast cancer rates in the Pacific where mammography services are limited are exceedingly high: Marshall Islands (61%), Palau (94%), and Samoa (79%). Due to the limited medical resources in these areas an alternative accessible technology is needed. The iBreast Exam (iBE) is a point‐of‐care electronic palpitation device that has a reported sensitivity of 86%. However, little is known about the performance and acceptability of this device for women in the Pacific. Methods: A total of 39 women (ages 42–73 years) were recruited in Guam with 19 women having a mammogram requiring biopsy (Breast Imaging‐Reporting and Data System [BI‐RADS] category 4 or above) and 20 women with a negative screening mammogram before the study visit. Participants received an iBE exam and completed a 26‐item breast health questionnaire to evaluate the iBE. Furthermore, the performance characteristics of the iBE were tested using gelatin breast phantoms in terms of tumor size, tumor depth, and overall breast stiffness. Results: The iBE had a sensitivity of 20% (two true positives to eight false negatives) and specificity of 92% (24 false positives to 278 true negatives) when analyzed based on the location of the tumor by quadrant. The iBE also had generally poor agreement according to a Cohen's kappa value of 0.068. The phantom experiments showed that the iBE can detect tumors as deep as 2.5 cm, but only if the lesion is greater than 8 mm in diameter. However, the iBE did demonstrate acceptability; 67% of the women reported that they had high trust in iBE as an early detection device. Conclusions: The iBE had generally poor sensitivity and specificity when tested in a clinical setting which does not allow its use as a screening tool. Impact: This study demonstrates the need for an alternative screening method other than electronic palpation for lower‐middle‐income areas. … (more)
- Is Part Of:
- Medical physics. Volume 49:Issue 4(2022)
- Journal:
- Medical physics
- Issue:
- Volume 49:Issue 4(2022)
- Issue Display:
- Volume 49, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 49
- Issue:
- 4
- Issue Sort Value:
- 2022-0049-0004-0000
- Page Start:
- 2663
- Page End:
- 2671
- Publication Date:
- 2022-02-10
- Subjects:
- accessibility -- breast -- cancer -- palpation -- screening
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15499 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27010.xml